低剂量脾灌注CT无创评估肝硬化患者食管静脉曲张
回顾性纳入43例伴食管静脉曲张(EV)的肝硬化患者(分轻、中、重度组)及14例肝功能正常无EV对照,行低剂量脾灌注CT测量BV、BF、PS及脾体积,计算脾总血容量BV-S;各组间BV、BF、PS、V-S、BV-S差异有统计学意义,平均DLP为1286.41±261.15 mGy*cm,有效辐射剂量19.30±3.92 mSv,结论认为低剂量脾灌注CT参数可用于无创评估EV程度。
要点
- 脾灌注CT可测量BV、BF、PS及脾体积V-S,并计算脾总血容量BV-S,用于无创评估肝硬化EV程度。
- 研究组较对照组PS、V-S、BV-S升高而BV、BF降低,EV2与EV1、EV2与EV3之间BV和BF差异有统计学意义。
- 平均DLP 1286.41±261.15 mGy*cm,有效辐射剂量19.30±3.92 mSv。
核心结论
- 低剂量脾灌注CT获得的脾灌注参数可用于无创评估肝硬化患者的食管静脉曲张程度。
研究设计与样本
- 回顾性研究,纳入43例伴食管静脉曲张的肝硬化患者(分轻度EV1、中度EV2、重度EV3组)及14例肝功能正常且无EV的对照组,均行低剂量脾灌注CT并记录辐射剂量,测量脾灌注参数BV、BF、PS及脾体积V-S,BV-S由V-S与BV乘积获得,采用Welch校正的ANOVA及LSD法进行多组比较,P<0.05为差异有统计学意义。
诊断标准与关键数值
- 各组间BV、BF、PS、V-S、BV-S差异均有统计学意义(p<0.05)。
- 研究组较对照组PS、V-S、BV-S升高,BV、BF降低。
- EV2与EV1组、EV2与EV3组之间BV和BF差异有统计学意义。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of splenic hemodynamic parameters measured using low-dose perfusion CT in the noninvasive evaluation of esophageal varices (EV) in patients with liver cirrhosis.
METHODS: We retrospectively studied 43 cirrhotic patients with EV, which were divided into mild (EV1), moderate (EV2) and severe (EV3) groups. 14 patients with normal liver function and no EV were selected as the control group. All patients underwent low-dose splenic perfusion CT and radiation dose were recorded. Spleen perfusion parameters, including blood volume (BV), blood flow (BF) and permeability surface (PS), were obtained. The volume of the spleen (V-S) was measured. The total blood volume of the spleen (BV-S) was obtained using the product of V-S and BV. The measurement differences among the four groups were analyzed using ANOVA with Welch correction. Least Significant Difference (LSD) was used for the multiple comparison. P < 0.05 was considered statistically significant.
RESULTS: There were statistically significant differences in BV, BF, PS, V-S, and BV-S among different groups (p < 0.05). PS, V-S, and BV-S were higher, and BV and BF were lower in the study groups than those in the control group. There was a statistically significant difference between EV2 and EV1 groups, and EV2 and EV3 groups in BV and BF. The average dose-length product (DLP) was 1286.41 ± 261.15 mGy*cm, and the effective radiation dose(Deff)was 19.30 ± 3.92 mSv.
CONCLUSION: The splenic perfusion parameters obtained in the low-dose splenic perfusion CT could be used to noninvasively evaluate the degrees of EV in cirrhotic patients.
引用
- Yan, Han, Liang, et al. Non-invasive evaluation of esophageal varices in patients with liver cirrhosis using low-dose splenic perfusion CT. Eur J Radiol. 2022. PMID: 35504216. doi:10.1016/j.ejrad.2022.110326
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。