观察肝窦毛细血管化评估肝纤维化:大鼠中超声分子成像与二维剪切波弹性成像的比较
在大鼠模型中前瞻性比较超声分子成像(USMI)与二维剪切波弹性成像(2D SWE)评估肝纤维化的效能。USMI以CD34靶向观察肝窦毛细血管化,用归一化强度差(NID)定量。USMI在早期肝纤维化检测中比2D SWE更准确,且不受炎症影响。
要点
- USMI通过CD34靶向观察肝窦毛细血管化,NID与胶原比例面积线性相关(r=0.91)。
- 检测早期肝纤维化时USMI的AUC为0.97,高于2D SWE的0.82(P=.01)。
- 肝炎大鼠肝硬度值高于对照组(9.83 kPa±0.79 vs 6.55 kPa±0.38;P<.001),但NID无差异(6.75%±1.43 vs 6.74%±0.86;P=.98)。
核心结论
- USMI观察肝窦毛细血管化有助于比2D SWE更准确地检测早期肝纤维化,并有助于不受炎症影响地评估纤维化。
研究设计与样本
- 前瞻性动物研究,于2021年1月至6月纳入120只雄性Sprague-Dawley大鼠,包括不同程度肝纤维化、急性肝炎及对照大鼠;行CD34靶向USMI和2D SWE,以胶原比例面积为参考进行线性相关和ROC分析。
关键影像表现/征象
- USMI以CD34靶向显示肝窦毛细血管化,并以归一化强度差(NID)进行定量分析。
- NID与胶原比例面积呈良好线性相关(r=0.91),肝硬度测量值(LSM)与胶原比例面积也呈良好线性相关(r=0.87)。
诊断标准与关键数值
- 检测F0-F1期时,USMI与2D SWE的ROC曲线下面积无差异(0.97 vs 0.91;P=.20)。
- 检测早期肝纤维化时,USMI的ROC曲线下面积高于2D SWE(0.97 vs 0.82;P=.01)。
- 肝炎大鼠肝硬度值高于对照大鼠(9.83 kPa±0.79 vs 6.55 kPa±0.38;P<.001),而NID值在对照大鼠与肝炎大鼠间无差异(6.75%±1.43 vs 6.74%±0.86;P=.98)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background US elastography is a first-line assessment of liver fibrosis severity; however, its application is limited by its insufficient sensitivity in early-stage fibrosis detection and its measurements are affected by inflammation. Purpose To assess the sensitivity of US molecular imaging (USMI) in early-stage liver fibrosis detection and to determine whether USMI can specifically distinguish fibrosis regardless of inflammation when compared with two-dimensional (2D) shear-wave elastography (SWE). Materials and methods USMI and 2D SWE were performed prospectively (January to June 2021) in 120 male Sprague-Dawley rats with varying degrees of liver fibrosis and acute hepatitis and control rats. Liver sinusoidal capillarization was viewed at CD34-targeted USMI and quantitatively analyzed by the normalized intensity difference (NID). Data were compared by using a two-sided Student t test or one-way analysis of variance. Linear correlation analyses were used to evaluate the relationships between collagen proportionate area values and NID and liver stiffness measurement (LSM) values. Receiver operating characteristic curves were used to assess the diagnostic performance in detecting liver fibrosis. Results Both NID and LSM values showed good linear correlation with collagen proportionate area values (r = 0.91 and 0.87, respectively). No difference was observed between the areas under the receiver operating characteristic curve in detecting stage F0-F1 between USMI and 2D SWE (0.97 vs 0.91, respectively; P = .20). USMI depicted liver fibrosis at an early stage more accurately than 2D SWE (area under the curve, 0.97 vs 0.82, respectively; P = .01). Rats with hepatitis had higher liver stiffness values than control rats (9.83 kPa ± 0.79 vs 6.55 kPa ± 0.38, respectively; P < .001), with no difference in the NID values between control rats and rats with hepatitis (6.75% ± 1.43 vs 6.74% ± 0.86, respectively; P = .98). Conclusion Sinusoidal capillarization viewed at US molecular imaging helped to detect early-stage liver fibrosis more accurately than two-dimensional shear-wave elastography and helped assess fibrosis regardless of inflammation. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Barr in this issue.
引用
- Miao, Sha, Zhang, et al. Liver Fibrosis Assessment by Viewing Sinusoidal Capillarization: US Molecular Imaging versus Two-dimensional Shear-Wave Elastography in Rats. Radiology. 2022. PMID: 35503015. doi:10.1148/radiol.212325
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。