肠管置管影像检查的临床优化方案:基于放射科医生判读的诊断效用与辐射剂量降低
研究开发并评估基于患者厚度的床旁腹部X线肠管置管确认方案,比较干预前后队列。干预后有效剂量显著降低80%(P<0.01),诊断质量无显著差异(基线92.5%可诊断 vs 干预96.5%,P=0.06)。结论为该方案降低患者有效剂量而不牺牲诊断准确性。
要点
- 基于患者厚度的肠管置管确认方案使有效剂量降低80%(P<0.01)。
- 基线92.5%(209/226)与干预96.5%(221/229)可诊断,差异无统计学显著(P=0.06)。
- 方案技术图表可供参考,开发流程可推广至其他影像临床任务。
核心结论
- 开发了针对肠管置管确认的优化方案,降低患者有效剂量而不牺牲诊断准确性,并提供技术图表供参考。
研究设计与样本
- 研究纳入干预前226张与干预后229张床旁腹部X线片,由七位专家放射科医生按标准化可见度分级(0不可诊断至3+)判读,记录患者人口学、体重指数、通气状态及肠管类型并做亚组分析,估算两队列有效剂量。
诊断标准与关键数值
- 标准化可见度分级:0为不可诊断,3+为最高级;基线209张(92.5%)可诊断,基于厚度方案221张(96.5%)可诊断,P=0.06。
临床应用与阅片要点
- 基于患者厚度的方案可用于床旁腹部X线肠管置管确认,在维持诊断质量的同时降低有效剂量;技术图表可供参考,开发流程可推广至其他影像临床任务。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The purpose of this study was to develop and evaluate a patient thickness-based protocol specifically for the confirmation of enteric tube placements in bedside abdominal radiographs. Protocol techniques were set to maintain image quality while minimizing patient dose.
MATERIALS AND METHODS: A total of 226 pre-intervention radiographs were obtained to serve as a baseline cohort for comparison. After the implementation of a thickness-based protocol, a total of 229 radiographs were obtained as part of an intervention cohort. Radiographs were randomized and graded for diagnostic quality by seven expert radiologists based on a standardized conspicuity scale (grades: 0 non-diagnostic to 3+). Basic patient demographics, body mass index, ventilatory status, and enteric tube type were recorded and subgroup analyses were performed. Effective dose was estimated for both cohorts.
RESULTS: The dedicated thickness-based protocol resulted in a significant reduction in effective dose of 80% (p-value < 0.01). There was no significant difference in diagnostic quality between the two cohorts with 209 (92.5%) diagnostic radiographs in the baseline and 221 (96.5%) diagnostic radiographs in the thickness-based protocol (p-value 0.06).
CONCLUSION: A protocol optimized for the confirmation of enteric tube placements was developed. This protocol results in lower patient effective dose, without sacrificing diagnostic accuracy. The technique chart is provided for reference. The protocol development process outlined in this work could be readily generalized to other imaging clinical tasks.
引用
- Klejch, Marshall, Blunt, et al. A Clinically Optimal Protocol for the Imaging of Enteric Tubes: On the Basis of Radiologist Interpreted Diagnostic Utility and Radiation Dose Reduction. Acad Radiol. 2022. PMID: 35504809. doi:10.1016/j.acra.2022.03.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。