检测膀胱癌的肌肉侵犯性:扩散峰度成像与肿瘤接触长度的应用
本研究纳入97例膀胱癌患者,评估扩散峰度成像(DKI)参数Kapp与肿瘤接触长度(TCL)对肌层浸润性膀胱癌(MIBC)的术前预测价值。结果显示MIBC组TCL(4.66±1.89)显著大于NMIBC组(1.88±1.50),Kapp、TCL、VI-RADS及两者联合的AUC分别为0.92、0.87、0.90和0.95,Kapp和TCL为MIBC独立危险因素。
要点
- MIBC组TCL(4.66±1.89)显著大于NMIBC组(1.88±1.50),Kapp在MIBC组更高(0.79±0.08 vs 0.62±0.01)。
- Kapp预测MIBC的AUC为0.92,优于常规DWI;TCL的AUC为0.87,VI-RADS为0.90。
- Kapp与TCL联合的AUC达0.95,为所有参数中最高,可补充VI-RADS预测肌肉侵犯。
核心结论
- Kapp预测MIBC的表现优于常规DWI,Kapp和TCL是MIBC的独立危险因素,两者联合可补充VI-RADS预测肌肉侵犯,且联合模型AUC最大、准确率最高。
研究设计与样本
- 共97例患者接受3.0 T MRI扫描,序列包括螺旋桨快速自旋回波T2WI、回波平面扩散加权成像(DWI)和动态对比增强成像(DCE);两名放射科医师独立阅片、进行VI-RADS分级、勾画感兴趣区并测量TCL;采用ICC、Kappa、Kolmogorov-Smirnov检验、Mann-Whitney U检验、卡方检验、logistic回归、Hosmer-Lemeshow检验及ROC曲线分析。
诊断标准与关键数值
- 在相应截断值下,TCL、Kapp、VI-RADS及Kapp联合TCL的AUC分别为0.87、0.92、0.90和0.95。
临床应用与阅片要点
- Kapp和TCL可作为VI-RADS的补充指标用于术前预测膀胱癌肌肉侵犯,两者联合模型表现出最高的AUC和准确率。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic efficacy of diffusion kurtosis imaging (DKI) parameters and tumor contact length (TCL) among clinical and radiological factors for preoperative prediction of muscle-invasive bladder cancer (MIBC).
METHOD: A total of ninety-seven patients underwent 3.0 T MRI scan with propeller fast spin-echo T2WI, echo planar imaging diffusion-weighted imaging (DWI), and dynamic contrast-enhanced imaging (DCE). Two radiologists independently viewed multiparametric MRI (mpMRI) of each patient, graded the VI-RADS, drew the region of interest (ROI) and measured TCL. Interclass correlation coefficients (ICCs), Kappa statistics, Kolmogorov-Smirnov test, Mann-Whitney U tests, chi-square tests, logistic regression analyses, Hosmer-Lemeshow tests, receiver operating characteristic curve (ROC) analysis, and area under the curve (AUC) were applied.
RESULTS: The mean Kapp of NMIBC group (0.62 ± 0.01) was significantly lower than that of MIBC group (0.79 ± 0.08). The mean TCL of MIBC group (4.66 ± 1.89) was significantly larger than TCL of NMIBC group (1.88 ± 1.50) (all p < 0.01). At the corresponding cut-off, AUC of TCL, Kapp, VI-RADS and the combination of Kapp and TCL were 0.87, 0.92, 0.90, and 0.95, respectively. TCL and Kapp were risk factors of BC muscle invasion at both univariate and multivariate analysis.
CONCLUSIONS: Kapp performed better than conventional DWI in predicting MIBC. Kapp and TCL were independent risk factors of MIBC and could complement VI-RADS for predicting muscle invasion. The combination of Kapp and TCL had the largest AUC and highest accuracy among all parameters.
引用
- Li, Cao, Liu, et al. Detecting the muscle invasiveness of bladder cancer: An application of diffusion kurtosis imaging and tumor contact length. Eur J Radiol. 2022. PMID: 35487092. doi:10.1016/j.ejrad.2022.110329