文献速递神经技术与安全MRPET

DSC灌注MRI衍生的分数肿瘤负荷与相对CBV可鉴别立体定向放射外科治疗脑转移瘤后的肿瘤进展与放射性坏死

DSC Perfusion MRI-Derived Fractional Tumor Burden and Relative CBV Differentiate Tumor Progression and Radiation Necrosis in Brain Metastases Treated with Stereotactic Radiosurgery.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-04-28

该回顾性研究评估了30例既往接受立体定向放射外科治疗的脑转移瘤患者共37个病灶,利用DSC灌注MRI获得的相对CBV和分数肿瘤负荷等指标鉴别放射性坏死与肿瘤进展。结果显示,肿瘤病灶的相对CBV和分数肿瘤负荷均高于放射性坏死,以相对CBV阈值≥1.75定义的高分数肿瘤负荷鉴别效能最佳,标准化与归一化方法表现相似。

要点

  • 相对CBV阈值≥1.75定义的高分数肿瘤负荷有助于鉴别肿瘤进展与放射性坏死。
  • 归一化相对CBV阈值≥1.75预测肿瘤的敏感度为76.5%、特异度为70.0%。
  • 标准化相对CBV阈值≥1.75预测肿瘤的敏感度为41.2%、特异度为95.0%。

核心结论

  • 在立体定向放射外科治疗的脑转移瘤患者中,相对CBV升高和高分数肿瘤负荷(以相对CBV阈值≥1.75定义)最能鉴别肿瘤与放射性坏死,归一化与标准化方法表现相似。

研究设计与样本

  • 回顾性研究,纳入30例受试者的37个病灶(放射性坏死20个,肿瘤17个),评估包括DSC、动态对比增强和动脉自旋标记灌注成像的MRI,部分受试者行FDG-PET。

关键影像表现/征象

  • 与放射性坏死相比,肿瘤的平均归一化和标准化相对CBV升高(P = .002)。
  • 与放射性坏死相比,肿瘤的高分数肿瘤负荷升高(归一化P = .005;标准化P = .003),低分数肿瘤负荷降低(归一化P = .03;标准化P = .01)。
  • 体积转移常数、归一化最大CBF和标准化摄取值在肿瘤与放射性坏死之间无统计学显著差异。

诊断标准与关键数值

  • 相对CBV鉴别肿瘤与放射性坏死的AUC:归一化0.80,标准化0.79。
  • 高分数肿瘤负荷鉴别肿瘤与放射性坏死的AUC:归一化0.77,标准化0.78。
  • 归一化相对CBV阈值≥1.75预测肿瘤的敏感度为76.5%,特异度为70.0%。
  • 标准化相对CBV阈值≥1.75预测肿瘤的敏感度为41.2%,特异度为95.0%。
  • 相对CBV阈值1和1.75分别用于定义低分数肿瘤负荷和高分数肿瘤负荷。

临床应用与阅片要点

  • 在立体定向放射外科治疗后的脑转移瘤随访中,可参考DSC灌注MRI获得的相对CBV和分数肿瘤负荷辅助鉴别肿瘤进展与放射性坏死。
  • 采用相对CBV阈值≥1.75定义的高分数肿瘤负荷时,需注意归一化与标准化方法的敏感度和特异度不同。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Differentiation between tumor and radiation necrosis in patients with brain metastases treated with stereotactic radiosurgery is challenging. We hypothesized that MR perfusion and metabolic metrics can differentiate radiation necrosis from progressive tumor in this setting.

MATERIALS AND METHODS: We retrospectively evaluated MRIs comprising DSC, dynamic contrast-enhanced, and arterial spin-labeling perfusion imaging in subjects with brain metastases previously treated with stereotactic radiosurgery. For each lesion, we obtained the mean normalized and standardized relative CBV and fractional tumor burden, volume transfer constant, and normalized maximum CBF, as well as the maximum standardized uptake value in a subset of subjects who underwent FDG-PET. Relative CBV thresholds of 1 and 1.75 were used to define low and high fractional tumor burden.

RESULTS: Thirty subjects with 37 lesions (20 radiation necrosis, 17 tumor) were included. Compared with radiation necrosis, tumor had increased mean normalized and standardized relative CBV (P = .002) and high fractional tumor burden (normalized, P = .005; standardized, P = .003) and decreased low fractional tumor burden (normalized, P = .03; standardized, P = .01). The area under the curve showed that relative CBV (normalized = 0.80; standardized = 0.79) and high fractional tumor burden (normalized = 0.77; standardized = 0.78) performed the best to discriminate tumor and radiation necrosis. For tumor prediction, the normalized relative CBV cutoff of ≥1.75 yielded a sensitivity of 76.5% and specificity of 70.0%, while the standardized cutoff of ≥1.75 yielded a sensitivity of 41.2% and specificity of 95.0%. No significance was found with the volume transfer constant, normalized CBF, and standardized uptake value.

CONCLUSIONS: Increased relative CBV and high fractional tumor burden (defined by a threshold relative CBV of ≥1.75) best differentiated tumor from radiation necrosis in subjects with brain metastases treated with stereotactic radiosurgery. Performance of normalized and standardized approaches was similar.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Kuo, Ng, Nagpal, et al. DSC Perfusion MRI-Derived Fractional Tumor Burden and Relative CBV Differentiate Tumor Progression and Radiation Necrosis in Brain Metastases Treated with Stereotactic Radiosurgery. AJNR Am J Neuroradiol. 2022. PMID: 35483909. doi:10.3174/ajnr.A7501

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。