超声估算膀胱重量与神经源性膀胱功能障碍的影像尿动力学检查结果相关
该回顾性研究纳入58例接受影像尿动力学和肾膀胱超声的脊柱裂患儿,评估哪些下尿路超声参数可预测作为参考标准的侵入性尿动力学结果。储尿末压高于15 cm H2O时膀胱质量、膀胱/体质量比和壁厚度增加;膀胱重量65 g、压力阈值30 cm H2O时敏感度75%、特异度84%,膀胱重量可能作为无创筛查工具。
要点
- 储尿末压高于15 cm H2O时膀胱质量、膀胱/体质量比和壁厚度增加。
- 膀胱重量65 g、压力阈值30 cm H2O时敏感度75%、特异度84%。
- 膀胱重量与腔内容积无关,可按体质量归一化,可能用于无创筛查。
核心结论
- 膀胱重量与腔内容积无关、可按体质量归一化,可能作为无创筛查工具,用于界定影像尿动力学结果异常可能性更高的神经源性膀胱患者亚组。
研究设计与样本
- 回顾性研究,纳入58例接受影像尿动力学评估和肾膀胱超声作为标准诊疗的脊柱裂患儿,将定量和定性超声参数与作为参考标准的影像尿动力学结果进行相关性分析。
关键影像表现/征象
- 储尿末压高于15 cm H2O的膀胱,膀胱质量增加(P = .00019)。
- 储尿末压高于15 cm H2O的膀胱,膀胱/体质量比增加(P = .0059)。
- 储尿末压高于15 cm H2O的膀胱,壁厚度增加(P = .01)。
诊断标准与关键数值
- 以储尿末压15、20、30、40 cm H2O为截断点计算受试者工作特征曲线。
- 膀胱重量65 g、压力截断点30 cm H2O时曲线下面积最优,敏感度75%、特异度84%。
临床应用与阅片要点
- 储尿末压高于15 cm H2O时,超声可见膀胱质量、膀胱/体质量比和壁厚度增加。
- 膀胱重量与腔内容积无关,可按体质量归一化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This retrospective study was designed to evaluate which lower urinary tract ultrasound parameter(s) could predict the results of invasive urodynamic testing which are the current reference standard in the evaluation of bladder dysfunction in children with spina bifida.
MATERIALS AND METHODS: Fifty eight children with spina bifida undergoing video urodynamic evaluation and a renal bladder ultrasound as their standard of care were evaluated. Quantitative and qualitative ultrasound parameters were then correlated with the videourodynamic study results which served as the reference standard.
RESULTS: For bladders with ending storage pressures above 15 cm H2 O, there were increases in these ultrasound measured parameters: 1) bladder mass (P = .00019), 2) bladder/body mass ratio (P = .0059), and 3) wall thickness (P = .01). We defined the storage cost as the final storage pressure divided by the percentage of expected bladder capacity attained. These data were analyzed to compute receiver operating curves with assuming end storage pressures cutoff points of 15, 20, 30, and 40 cm H2 O. The optimal area under the curve was found for a bladder weight of 65 g and a pressure cutoff of 30 cm H2 O with a sensitivity of 75% with a specificity of 84%.
CONCLUSION: Bladder weight is independent of luminal volume, can be normalized to body weight, and may serve as a clinically valuable tool for noninvasive screening to define a subset of patients with neurogenic bladder with a higher likelihood of having abnormal videourodynamic results.
引用
- Hwang, Back, Van Batavia, et al. Ultrasound-Estimated Bladder Weight Correlates With Videourodynamic Studies in Neurogenic Bladder Dysfunction. J Ultrasound Med. 2022. PMID: 35460290. doi:10.1002/jum.15995
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。