文献速递胸部腹部CTPET

基于内镜图像深度学习预测可切除局部晚期食管鳞癌新辅助放化疗后病理完全缓解的模型

A prediction model for pathological findings after neoadjuvant chemoradiotherapy for resectable locally advanced esophageal squamous cell carcinoma based on endoscopic images using deep learning.
PubMed 文献 · Br J Radiol · 2022-05-23

回顾性分析2004至2016年98例接受术前放化疗后手术的局部晚期食管癌患者内镜图像,按局部控制分为应答组与非应答组,用卷积神经网络预测病理完全缓解;交叉验证平均AUC无滤波0.58、Laplacian滤波0.67、Sobel滤波0.73、小波滤波0.83,加用影像滤波后准确率显著提高。

要点

  • 小波滤波卷积神经网络交叉验证平均AUC 0.83,高于无滤波0.58。
  • 小波滤波交叉验证平均敏感度0.80、特异度0.81、准确率0.81。
  • Sobel滤波交叉验证平均准确率0.71、敏感度0.67、特异度0.68、AUC 0.73。

核心结论

  • 加用影像滤波可提高基于内镜图像深度学习模型预测病理完全缓解的准确率,该模型可辅助临床肿瘤医师更准确预判治疗结局。

研究设计与样本

  • 回顾性研究,纳入2004至2016年98例接受术前放化疗后手术的局部晚期食管癌患者,72例训练模型、26例测试模型;内镜图像转为JPEG并缩放到150×150像素,比较无滤波与Laplacian、Sobel、小波滤波的卷积神经网络模型。

诊断标准与关键数值

  • 交叉验证平均准确率:无滤波0.64、Laplacian滤波0.69、Sobel滤波0.71、小波滤波0.81;平均敏感度:无滤波0.80、Laplacian滤波0.81、Sobel滤波0.67、小波滤波0.80;平均特异度:无滤波0.37、Laplacian滤波0.55、Sobel滤波0.68、小波滤波0.81;平均AUC:无滤波0.58、Laplacian滤波0.67、Sobel滤波0.73、小波滤波0.83。

临床应用与阅片要点

  • 作者认为加用影像滤波的深度学习模型可辅助临床肿瘤医师更准确预判治疗结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To propose deep-learning (DL)-based predictive model for pathological complete response rate for resectable locally advanced esophageal squamous cell carcinoma (SCC) after neoadjuvant chemoradiotherapy (NCRT) with endoscopic images.

METHODS AND MATERIAL: This retrospective study analyzed 98 patients with locally advanced esophagus cancer treated by preoperative chemoradiotherapy followed by surgery from 2004 to 2016. The patient data were split into two sets: 72 patients for the training of models and 26 patients for testing of the model. Patients was classified into two groups with the LC (Group I: responder and Group II: non-responder). The scanned images were converted into joint photographic experts group (JPEG) format and resized to 150 × 150 pixels. The input image without imaging filter (w/o filter) and with Laplacian, Sobel, and wavelet imaging filters deep-learning model to predict the pathological CR with a convolution neural network (CNN). The accuracy, sensitivity, and specificity, the area under the curve (AUC) of the receiver operating characteristic were evaluated.

RESULTS: The average of accuracy for the cross-validation was 0.64 for w/o filter, 0.69 for Laplacian filter, 0.71 for Sobel filter, and 0.81 for wavelet filter, respectively. The average of sensitivity for the cross-validation was 0.80 for w/o filter, 0.81 for Laplacian filter, 0.67 for Sobel filter, and 0.80 for wavelet filter, respectively. The average of specificity for the cross-validation was 0.37 for w/o filter, 0.55 for Laplacian filter, 0.68 for Sobel filter, and 0.81 for wavelet filter, respectively. From the ROC curve, the average AUC for the cross-validation was 0.58 for w/o filter, 0.67 for Laplacian filter, 0.73 for Sobel filter, and 0.83 for wavelet filter, respectively.

CONCLUSIONS: The current study proposed the improvement the accuracy of the DL-based prediction model with the imaging filters. With the imaging filters, the accuracy was significantly improved. The model can be supported to assist clinical oncologists to have a more accurate expectations of the treatment outcome.

ADVANCES IN KNOWLEDGE: The accuracy of the prediction for the local control after radiotherapy can improve with the input image with the imaging filter for deep learning.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Kawahara, Murakami, Tani, et al. A prediction model for pathological findings after neoadjuvant chemoradiotherapy for resectable locally advanced esophageal squamous cell carcinoma based on endoscopic images using deep learning. Br J Radiol. 2022. PMID: 35451338. doi:10.1259/bjr.20210934

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。