快速MRI T2序列诊断Roux-en-Y胃旁路术后妊娠患者内疝的诊断准确性:一项回顾性单中心研究
该回顾性单中心研究纳入31例有Roux-en-Y胃旁路术史的妊娠患者,因临床怀疑内疝而行腹部MRI,由两名腹部放射科医生独立评估T2 HASTE序列。以临床诊断(手术探查或90天随访无内疝症状)为金标准,T2 HASTE诊断内疝的准确率87.9%–90.3%,敏感度88.9%–100.0%,特异度80.0%–86.7%,NPV 86.7%–100.0%,观察者间一致性0.741。作者认为T2 HASTE MRI对妊娠患者内疝检测具有 excellent 敏感度和NPV,快速采集时间使其可用于急诊场景。
要点
- 妊娠患者疑内疝时,T2 HASTE序列诊断准确率87.9%–90.3%,敏感度88.9%–100.0%。
- T2 HASTE的NPV为86.7%–100.0%,有助于排除内疝。
- 两名腹部放射科医生评估内疝的观察者间一致性为0.741。
核心结论
- T2 HASTE MRI对妊娠Roux-en-Y胃旁路术后患者内疝检测具有 excellent 敏感度和NPV,快速采集时间使其在急诊场景中有用,可用于内疝的诊断或排除。
研究设计与样本
- 回顾性单中心研究,纳入31例有Roux-en-Y胃旁路术史且临床怀疑内疝的妊娠患者腹部MRI,由两名腹部放射科医生独立评估T2 HASTE序列轴位、冠状位和矢状位图像,以临床诊断(手术探查见肠管疝入肠系膜缺损或90天随访无内疝症状)为金标准。
诊断标准与关键数值
- T2 HASTE MRI诊断内疝的准确率87.9%–90.3%,敏感度88.9%–100.0%,特异度80.0%–86.7%,NPV 86.7%–100.0%,两名读者间一致性0.741;内疝金标准为手术探查见肠管疝入肠系膜缺损,无内疝为手术探查未见疝入肠管或90天临床随访无内疝症状。
临床应用与阅片要点
- 作者认为T2 HASTE MRI可用于妊娠Roux-en-Y胃旁路术后患者内疝的诊断或排除,快速采集时间使其在急诊场景中有用。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The objective of this retrospective study was to evaluate the diagnostic accuracy of a fast sequence Magnetic Resonance Imaging (MRI) sequence, T2- half-Fourier acquisition single-shot turbo spin echo (HASTE) for the diagnosis of internal herniation (IH) in pregnant patients with a history of Roux-en-Y gastric bypass (RYGB).
METHODS: Abdominal MRI studies, performed for the clinical suspicion of IH of pregnant patients with a history of RYGB, were analyzed by two abdominal radiologists. Thirty-one cases were included and for each case both readers independently evaluated the T2 HASTE sequence in different planes (axial, coronal and sagittal) to determine the presence or absence of IH. Diagnostic performance of T2 HASTE MRI was evaluated by calculating sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy compared to the clinical diagnosis of IH as the gold standard. IH was diagnosed as the presence of herniated bowel through the mesenteric defect at the time of surgical exploration. IH was deemed absent if the surgical exploration showed no herniated bowel or if patients had no subsequent clinical symptoms of IH after 90 days of clinical follow-up.
RESULTS: The results in this study, with 16 patients with IH and 15 patients without IH, portray a high accuracy for the detection of IH, ranging from 87.9% to 90.3%. This fast T2 sequence shows a high NPV (86.7% - 100.0% 87.7), sensitivity (88.9% - 100.0%) and specificity (80.0% - 86.7%). This study also portrayed a substantial interobserver agreement (0.741) for the evaluation of IH.
CONCLUSION: T2 HASTE MRI shows an excellent sensitivity and NPV for the detection of IH in pregnant patients. The fast acquisition time makes this sequence useful in the emergency setting, and it can be used for the diagnosis or exclusion of IH in pregnant patients.
引用
- Van Berkel, Gillardin, Sneyers, et al. Diagnostic accuracy of a fast MRI T2-sequence for the diagnosis of internal herniation after Roux-and-Y gastric bypass during pregnancy: A retrospective single center study. Eur J Radiol. 2022. PMID: 35452955. doi:10.1016/j.ejrad.2022.110318
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。