急性缺血性卒中患者体素内不相干运动成像的观察者间信度
回顾性纳入29例急性缺血性卒中患者,在1.5T MR上行体素内不相干运动成像,由2名神经放射科医师对灌注分数和伪扩散系数较对侧正常脑组织降低进行2级评分,观察者间信度分别为κ=0.854和κ=0.789;灌注分数未降低的患者更常出现闭塞颅内动脉再通。
要点
- 体素内不相干运动灌注分数图观察者间信度κ=0.854,伪扩散系数图κ=0.789。
- 体素内不相干运动成像可在常规DWI基础上于1分钟内完成。
- 灌注分数未降低者较降低者更常出现闭塞颅内动脉再通。
核心结论
- 体素内不相干运动MR成像可在常规DWI基础上于1分钟内完成,其参数无创地提供可行的定性灌注相关信息用于评估急性缺血性卒中患者。
研究设计与样本
- 回顾性研究纳入29例急性缺血性卒中患者(男17例、女12例,平均年龄75.2岁[SD 12.0],中位77岁),使用1.5T MR扫描仪行体素内不相干运动MR成像,扩散敏感梯度依次施加于x、y、z方向,采用6个b值(0、50、100、150、200、1000秒/mm²),基于Levenberg-Marquardt法的两步拟合算法获得扩散系数、灌注分数和伪扩散系数图,由2名独立神经放射科医师对灌注分数和伪扩散系数较对侧表现正常脑组织降低进行2级评分。
诊断标准与关键数值
- 灌注分数图观察者间信度κ=0.854,伪扩散系数图κ=0.789;灌注分数和/或伪扩散系数较对侧表现正常脑组织降低的存在与否采用2级评分。
临床应用与阅片要点
- 灌注分数和伪扩散系数较对侧正常脑组织降低的2级评分具有几乎完美(κ=0.854)和高度(κ=0.789)的观察者间信度;灌注分数未降低的患者似乎更常出现闭塞颅内动脉再通。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Noninvasive perfusion-weighted imaging with short scanning time could be advantageous in order to determine presumed penumbral regions and subsequent treatment strategy for acute ischemic stroke (AIS). Our aim was to evaluate interobserver agreement and the clinical utility of intravoxel incoherent motion MR imaging in patients with acute ischemic stroke.
MATERIALS AND METHODS: We retrospectively studied 29 patients with AIS (17 men, 12 women; mean age, 75.2 [SD, 12.0 ] years; median, 77 years). Each patient underwent intravoxel incoherent motion MR imaging using a 1.5T MR imaging scanner. Diffusion-sensitizing gradients were applied sequentially in the x, y, and z directions with 6 different b-values (0, 50, 100, 150, 200, and 1000 seconds/mm2). From the intravoxel incoherent motion MR imaging data, diffusion coefficient, perfusion fraction, and pseudodiffusion coefficient maps were obtained using a 2-step fitting algorithm based on the Levenberg-Marquardt method. The presence of decreases in the intravoxel incoherent motion perfusion fraction and pseudodiffusion coefficient values compared with the contralateral normal-appearing brain was graded on a 2-point scale by 2 independent neuroradiologists. Interobserver agreement on the rating scale was evaluated using the κ statistic. Clinical characteristics of patients with a nondecreased intravoxel incoherent motion perfusion fraction and/or pseudodiffusion coefficient rated by the 2 observers were also assessed.
RESULTS: Interobserver agreement was shown for the intravoxel incoherent motion perfusion fraction (κ = 0.854) and pseudodiffusion coefficient (κ = 0.789) maps, which indicated almost perfect and substantial agreement, respectively. Patients with a nondecreased intravoxel incoherent motion perfusion fraction tended to show recanalization of the occluded intracranial arteries more frequently than patients with a decreased intravoxel incoherent motion perfusion fraction.
CONCLUSIONS: Intravoxel incoherent motion MR imaging could be performed in < 1 minute in addition to routine DWI. Intravoxel incoherent motion parameters noninvasively provide feasible, qualitative perfusion-related information for assessing patients with acute ischemic stroke.
引用
- Yamashita, Kamei, Sugimori, et al. Interobserver Reliability on Intravoxel Incoherent Motion Imaging in Patients with Acute Ischemic Stroke. AJNR Am J Neuroradiol. 2022. PMID: 35450854. doi:10.3174/ajnr.A7486