文献速递神经MRCT

磁共振动态磁敏感对比灌注加权成像与CT灌注评估脑肿瘤的比较研究

Assessment of brain tumors by magnetic resonance dynamic susceptibility contrast perfusion-weighted imaging and computed tomography perfusion: a comparison study.
PubMed 文献 · Radiol Med · 2022-04-20

该回顾性研究纳入97例高、低级别胶质瘤及单发脑转移患者,比较DSC-PWI与CTP在评估肿瘤血管性和通透性中的关联与一致性。结果显示DSC-PWI与CTP的CBF、CBV图具有强相关性和良好一致性,可互换使用;而K2与PS图一致性较差。CTP可作为MRI不可用或患者不耐受时的替代方法量化肿瘤新生血管。

要点

  • DSC-PWI与CTP的CBF图强相关(r=0.79)且一致性高,CBV图相关更强(r=0.83)且一致性良好。
  • DSC-PWI的K2与CTP的PS仅弱相关(r=0.29)且一致性较差,评估肿瘤通透性时两者不可互换。
  • 高、低级别胶质瘤间所有DSC-PWI和CTP参数均有显著差异(p<0.01或p<0.001)。

核心结论

  • DSC-PWI与CTP的CBF和CBV图在评估肿瘤血管性方面具有可比性且可互换,而K2与PS图在分析肿瘤通透性时一致性较差;当MRI不可用或患者不耐受时,CTP可作为量化肿瘤新生血管的替代方法。

研究设计与样本

  • 回顾性研究,纳入97例高、低级别胶质瘤及单发脑转移患者,回顾其DSC-PWI和CTP检查,获取nCBF、nCBV、nK2及nPS值,比较组间变量并检验两种方法的相关性和一致性。

诊断标准与关键数值

  • 高、低级别胶质瘤间所有DSC-PWI和CTP参数比较,p<0.01及p<0.001。
  • 脑转移瘤DSC-PWI nCBV(p<0.05)、CTP nCBF(p<0.05)、CTP nCBV(p<0.01)和CTP nPS(p<0.0001)高于低级别胶质瘤。
  • 脑转移瘤CTP nPS较高、低级别胶质瘤更升高(p<0.01)。
  • DSC-PWI nCBF与CTP nCBF强相关(r=0.79;p<0.00001),DSC-PWI nCBV与CTP nCBV强相关(r=0.83;p<0.00001),DSC-PWI nK2与CTP nPS弱相关(r=0.29;p<0.01)。
  • Bland-Altman图显示DSC-PWI nCBF与CTP nCBF一致性高,DSC-PWI nCBV与CTP nCBV一致性良好,DSC-PWI nK2与CTP nPS一致性较差。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To investigate the association and agreement between magnetic resonance dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) and computed tomography perfusion (CTP) in determining vascularity and permeability of primary and secondary brain tumors.

MATERIAL AND METHODS: DSC-PWI and CTP studies from 97 patients with high-grade glioma, low-grade glioma and solitary brain metastasis were retrospectively reviewed. Normalized cerebral blood flow (nCBF), cerebral blood volume (nCBV), capillary transfer constant (nK2) and permeability surface area product (nPS) values were obtained. Variables among groups were compared, and correlation and agreement between DSC-PWI and CTP were tested.

RESULTS: All DSC-PWI and CTP parameters were higher in high-grade than in low-grade gliomas (p < 0.01 and p < 0.001). Metastases had greater DSC-PWI nCBV (p < 0.05), nCTP-CBF (p < 0.05), nCTP-CBV (p < 0.01) and nCTP-PS (p < 0.0001) than low-grade gliomas and more elevated nCTP-PS (p < 0.01) than high-grade gliomas. The correlation was strong between DSC-PWI nCBF and CTP nCBF (r = 0.79; p < 0.00001) and between DSC-PWI nCBV and CTP nCBV (r = 0.83; p < 0.00001), weaker between DSC-PWI nK2 and CTP nPS (r = 0.29; p < 0.01). Bland-Altman plots indicated that the agreement was strong between DSC-PWI nCBF and CTP nCBF, good between DSC-PWI nCBV and CTP nCBV and poorer between DSC-PWI nK2 and CTP nPS.

CONCLUSION: DSC-PWI and CTP CBF and CBV maps were comparable and interchangeable in the assessment of tumor vascularity, unlike DSC-PWI K2 and CTP PS maps that were more discordant in the analysis of tumor permeability. CTP could be an alternative method to quantify tumor neoangiogenesis when MRI is not available or when the patient does not tolerate it.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Scola, Desideri, Bianchi, et al. Assessment of brain tumors by magnetic resonance dynamic susceptibility contrast perfusion-weighted imaging and computed tomography perfusion: a comparison study. Radiol Med. 2022. PMID: 35441970. doi:10.1007/s11547-022-01470-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。