文献速递骨肌MRCT

采用后小转子线在MRI上量化股骨颈前倾角:三种测量方法的比较

MRI quantification of femoral neck version using the posterior lesser trochanteric line: a comparison of three measurements.
PubMed 文献 · Skeletal Radiol · 2022-04-18

本研究回顾性纳入45例因股髋撞击症行3T MRI检查的患者(90侧下肢),由两名肌骨放射科医生测量,验证以股骨后小转子线(PLTL)在MRI上量化股骨颈前倾角(FNV)的可行性,并与CT对照、与上髁法及后髁法比较可靠性。结果显示PLTL的MRI与CT测量一致性高(Lin一致性相关系数0.96,95%CI 0.94-0.98),PLTL观察者间可靠性良好(0.825,95%CI 0.732-0.918),优于上髁法(0.601)与后髁法(0.632);作者认为PLTL在MRI上测量FNV与CT相当,可帮助避免CT带来的不必要辐射暴露并缩短MRI扫描时间。

要点

  • PLTL法在MRI上测量股骨颈前倾角与CT测量高度一致,Lin一致性相关系数0.96(95%CI 0.94-0.98)。
  • PLTL法观察者间可靠性良好(Lin相关系数0.825),高于上髁法0.601与后髁法0.632。
  • 三种测量方法的Bland-Altman图相似且未见偏倚,观察者内可靠性均>0.900。

核心结论

  • MRI测量PLTL与CT测量结果相当。
  • PLTL在MRI上量化FNV的观察者间可靠性良好,可能有助于避免CT带来的不必要辐射暴露并缩短MRI扫描时间。

研究设计与样本

  • 回顾性研究,回顾因股髋撞击症(FAI)行3T MRI的病例。
  • 共纳入45例患者(90侧下肢),年龄20至41岁,平均31.5岁,女性22例、男性23例。
  • 由两名肌骨放射科医生完成测量;MRI的PLTL测量与CT比较采用Bland-Altman分析、Lin一致性相关系数与Lin相关系数。

诊断标准与关键数值

  • MRI与CT测量PLTL的Lin一致性相关系数为0.96(95%CI 0.94-0.98)。
  • PLTL的Lin相关系数为0.825(95%CI 0.732-0.918),提示观察者间可靠性良好。
  • 上髁法Lin相关系数为0.601(95%CI 0.415-0.786),后髁法为0.632(95%CI 0.456-0.807),均提示观察者间可靠性中等。
  • 各测量方法的Bland-Altman图相似且未见偏倚;观察者内可靠性>0.900,95%CI重叠显著。

临床应用与阅片要点

  • 作者认为,采用PLTL在MRI上量化股骨颈前倾角与CT相当,可能有助于避免CT的不必要辐射暴露并缩短MRI扫描时间。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To validate MRI for the quantification of the femoral neck version (FNV) using posterior lesser trochanteric Line (PLTL) and to compare reliability of the PLTL to the epicondylar and retrocondylar measurements.

MATERIALS AND METHODS: A retrospective review of 3 T MRI scans performed for femoroacetabular impingement (FAI). Two musculoskeletal radiologists performed the measurements. MRI measurements of the PLTL were compared to CT using Bland Altman, Lin's concordance, and Lin's correlation coefficients. Interobserver reliability was determined using Bland Altman, Lin's concordance, and Lin's correlation coefficients. Intraobserver reliability was determined using Lin's concordance and Lin's correlation coefficients.

RESULTS: Forty-five patients (90 lower extremities) met the inclusion criteria. Ages ranged from 20 to 41 years, with a mean of 31.5 years. There were 22 females and 23 males. Lin's concordance correlation coefficient for MRI and CT measurements of PLTL was substantial: 0.96 (95% CI: 0.94-0.98). PLTL Lin's correlation coefficient was 0.825 (95% CI 0.732-0.918) and indicated good interobserver reliability. Epicondylar and retrocondylar methods Lin's correlation coefficients demonstrated moderate interobserver reliability at 0.601 (0.415-0.786) and 0.632 (0.456-0.807), respectively. There was moderate 95% confidence interval overlap between the PLTL and the other measurements. Bland-Altman plots for each measurement were similar and demonstrated no bias. There was excellent intraobserver reliability (> 0.900) with significant 95% confidence interval overlap.

CONCLUSION: MRI measurements of the PLTL are comparable to CT. The PLTL has good reliability between readers for the quantification of FNV using MRI, which could help avoid unnecessary radiation exposure using CT and reduce MRI scan time.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Dhaliwal, Sahota, Mondal, et al. MRI quantification of femoral neck version using the posterior lesser trochanteric line: a comparison of three measurements. Skeletal Radiol. 2022. PMID: 35437644. doi:10.1007/s00256-022-04057-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。