文献速递乳腺乳腺X线

基于人工智能的乳腺癌乳腺X线筛查方案:结局与放射科医生工作量

An Artificial Intelligence-based Mammography Screening Protocol for Breast Cancer: Outcome and Radiologist Workload.
PubMed 文献 · Radiology · 2022-04-19

这项回顾性模拟研究分析了丹麦首都地区乳腺癌筛查项目2014年1月至2015年12月连续收集的114 421例次乳腺X线检查,使用AI工具对乳腺X线片进行0–10分恶性风险评分,模拟将评分<5的正常乳腺X线片排除出放射科医生阅片、评分>召回阈值的可疑乳腺X线片直接召回、其余由两名放射科医生阅片。AI筛查敏感度69.7%非劣效于放射科医生70.8%(P=0.02),特异度98.6%高于放射科医生98.1%(P<0.001),放射科医生工作量减少62.6%,避免25.1%的假阳性筛查。

要点

  • AI筛查敏感度69.7%非劣效于放射科医生70.8%(P=0.02)。
  • AI筛查特异度98.6%高于放射科医生98.1%(P<0.001)。
  • 放射科医生工作量减少62.6%,避免25.1%的假阳性筛查。

核心结论

  • 基于AI的筛查可检出乳腺癌筛查项目中的正常、中危和可疑乳腺X线片,可能减少放射科医生工作量,且在不同BI-RADS乳腺密度间表现一致,但敏感度在各BI-RADS密度间的一致性未达统计学显著。

研究设计与样本

  • 回顾性模拟研究,分析丹麦首都地区乳腺癌筛查项目2014年1月至2015年12月连续收集的114 421例次乳腺X线检查(114 421名女性),使用AI工具对乳腺X线片进行0–10分恶性风险评分;召回阈值通过另一独立队列(同一机构)匹配放射科医生敏感度拟合;模拟方案为评分<5的正常乳腺X线片排除出放射科医生阅片、评分>召回阈值的可疑乳腺X线片召回、其余由两名放射科医生阅片;采用Farrington-Manning检验验证AI筛查敏感度非劣效于放射科医生筛查,采用McNemar检验比较特异度。

诊断标准与关键数值

  • AI筛查敏感度69.7%(779/1118;95%CI:66.9,72.4),放射科医生筛查敏感度70.8%(791/1118;95%CI:68.0,73.5),非劣效检验P=0.02;AI筛查特异度98.6%(111 725/113 303;95%CI:98.5,98.7),放射科医生特异度98.1%(111 196/113 303;95%CI:98.1,98.2),P<0.001;正常乳腺X线片定义为AI评分<5,可疑乳腺X线片定义为AI评分>召回阈值(RT)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Developments in artificial intelligence (AI) systems to assist radiologists in reading mammograms could improve breast cancer screening efficiency. Purpose To investigate whether an AI system could detect normal, moderate-risk, and suspicious mammograms in a screening sample to safely reduce radiologist workload and evaluate across Breast Imaging Reporting and Data System (BI-RADS) densities. Materials and Methods This retrospective simulation study analyzed mammographic examination data consecutively collected from January 2014 to December 2015 in the Danish Capital Region breast cancer screening program. All mammograms were scored from 0 to 10, representing the risk of malignancy, using an AI tool. During simulation, normal mammograms (score < 5) would be excluded from radiologist reading and suspicious mammograms (score > recall threshold [RT]) would be recalled. Two radiologists read the remaining mammograms. The RT was fitted using another independent cohort (same institution) by matching to the radiologist sensitivity. This protocol was further applied to each BI-RADS density. Screening outcomes were measured using the sensitivity, specificity, workload, and false-positive rate. The AI-based screening was tested for noninferiority sensitivity compared with radiologist screening using the Farrington-Manning test. Specificities were compared using the McNemar test. Results The study sample comprised 114 421 screenings for breast cancer in 114 421 women, resulting in 791 screen-detected, 327 interval, and 1473 long-term cancers and 2107 false-positive screenings. The mean age of the women was 59 years ± 6 (SD). The AI-based screening sensitivity was 69.7% (779 of 1118; 95% CI: 66.9, 72.4) and was noninferior (P = .02) to the radiologist screening sensitivity of 70.8% (791 of 1118; 95% CI: 68.0, 73.5). The AI-based screening specificity was 98.6% (111 725 of 113 303; 95% CI: 98.5, 98.7), which was higher (P < .001) than the radiologist specificity of 98.1% (111 196 of 113 303; 95% CI: 98.1, 98.2). The radiologist workload was reduced by 62.6% (71 585 of 114 421), and 25.1% (529 of 2107) of false-positive screenings were avoided. Screening results were consistent across BI-RADS densities, although not significantly so for sensitivity. Conclusion Artificial intelligence (AI)-based screening could detect normal, moderate-risk, and suspicious mammograms in a breast cancer screening program, which may reduce the radiologist workload. AI-based screening performed consistently across breast densities. © RSNA, 2022 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Lauritzen, Rodríguez-Ruiz, von Euler-Chelpin, et al. An Artificial Intelligence-based Mammography Screening Protocol for Breast Cancer: Outcome and Radiologist Workload. Radiology. 2022. PMID: 35438561. doi:10.1148/radiol.210948

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。