儿科人群脊髓空洞快速脊柱磁共振评估的可行性
本研究纳入76例因Chiari畸形、疑似Chiari畸形或脊髓空洞接受标准脊柱影像检查的儿童(1月龄至18岁,平均7岁),在标准序列之外加做快速矢状位和轴位T2 HASTE序列,由一名儿科神经放射科医生分别判读。快速序列诊断脊髓空洞的敏感度为87.8%、特异度为94.7%,直径>2.3 mm的空洞均被识别;快速序列对低位圆锥敏感度为100%、对小脑扁桃体下疝敏感度为98.2%。
要点
- 快速T2 HASTE序列诊断儿童脊髓空洞敏感度87.8%、特异度94.7%,直径>2.3 mm的空洞均被识别。
- 快速序列对低位圆锥敏感度100%、对小脑扁桃体下疝敏感度98.2%。
- 终丝仅在31.6%的快速脊柱检查中被识别。
核心结论
- 快速T2成像对脊髓空洞的存在和范围显示较高敏感度,在部分患者中可能替代传统、耗时的标准脊柱成像。
研究设计与样本
- 纳入因Chiari畸形、疑似Chiari畸形或脊髓空洞接受标准脊柱成像的儿童,签署知情同意后在标准脊柱成像之外加做快速采集矢状位和轴位T2 HASTE脊柱序列。
- 共76例患者,年龄1月龄至18岁(平均7岁)符合纳入标准。
- 标准与快速脊柱成像由一名儿科神经放射科医生分别判读,评估有无脊髓空洞、空洞直径和长度,并记录小脑扁桃体下疝程度、圆锥位置及终丝评估情况。
关键影像表现/征象
- 快速脊柱成像诊断脊髓空洞的敏感度为87.8%、特异度为94.7%。
- 直径>2.3 mm的空洞均被快速脊柱序列识别。
- 快速与标准脊柱成像在空洞直径或长度评估上无统计学显著差异。
- 与标准脊柱成像相比,快速脊柱序列对低位圆锥的敏感度为100%,对小脑扁桃体下疝的敏感度为98.2%。
- 终丝仅在31.6%的快速脊柱检查中被识别。
诊断标准与关键数值
- 快速脊柱成像(矢状位和轴位T2 HASTE序列)诊断脊髓空洞:敏感度87.8%、特异度94.7%,以标准脊柱成像为对照。
- 快速脊柱序列识别直径>2.3 mm脊髓空洞的敏感度未单独给出数值,原文仅报告该直径以上的空洞均被识别。
- 快速脊柱序列对低位圆锥敏感度100%,对小脑扁桃体下疝敏感度98.2%,均以标准脊柱成像为对照。
临床应用与阅片要点
- 快速T2 HASTE序列可用于儿童脊柱检查中脊髓空洞的初步筛查,对直径>2.3 mm的空洞识别较可靠。
- 快速序列对低位圆锥和小脑扁桃体下疝的评估敏感度高,但终丝显示率仅31.6%,评估终丝相关异常时需结合标准序列。
- 作者认为快速T2成像在部分患者中可能替代传统、耗时的标准脊柱成像。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study investigates the feasibility of ultrafast fluid sensitive techniques for evaluation of pediatric spinal cord syrinx. Rapid imaging could obviate the need for sedation, which is often required for children undergoing lengthier standard spine imaging.
METHODS: Children undergoing standard spine imaging for Chiari malformation, suspected Chiari malformation, or syrinx were included. Patients who provided informed consent were imaged with rapid acquisition sagittal and axial T2 HASTE spine sequences in addition to standard spine imaging. Standard and rapid spine imaging were then reviewed separately by a pediatric neuroradiologist. The presence or absence of syrinx, syrinx diameter, and length were assessed. The degree of cerebellar tonsillar ectopia, conus position, and evaluation of the filum were also recorded.
RESULTS: Seventy-six patients aged 1 month to 18 years (mean 7 years) met the inclusion criteria. The sensitivity and specificity of rapid spine imaging for syrinx was 87.8% and 94.7% respectively. All syrinxes > 2.3 mm in diameter were identified with the rapid spine sequences. There was no statistically significant difference between rapid and standard spine imaging in assessment of syrinx diameter or length. Compared with standard spine imaging, rapid spine sequences demonstrated a 100% sensitivity for low-lying conus and a 98.2% sensitivity for cerebellar tonsillar ectopia. The filum was identified on only 31.6% of the rapid spine studies.
CONCLUSION: Rapid T2 imaging demonstrated a high sensitivity for the presence and extent of spinal cord syrinx and may provide an alternative to traditional, lengthier standard spine imaging in selected patients.
引用
- Ryan, Jaju, Rychlik, et al. Feasibility of rapid spine magnetic resonance evaluation for spinal cord syrinx in the pediatric population. Neuroradiology. 2022. PMID: 35437634. doi:10.1007/s00234-022-02960-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。