研究回顾性选取120例心脏磁共振检查,开发免费软件FLORA对延迟钆增强区域进行识别、分类和定量,并与放射科医生评估比较。FLORA在几乎全部病例中识别出缺血性和非缺血性心肌病变,双高斯拟合法和固定位移法的敏感度分别为100%和55%,特异度分别为98.8%和50%。
要点
- FLORA可半自动识别和分类LGE区域,缺血性心肌损伤分类正确率最高达85%-95%。
- 双高斯拟合法敏感度100%、特异度98.8%;固定位移法敏感度55%、特异度50%。
- FLORA提高观察者间一致性,并支持透壁程度的定量评估。
核心结论
- FLORA是一款可用的工具,能够改善和简化LGE区域的分类并实现定量。
研究设计与样本
- 回顾性研究,选取120例心脏磁共振检查,包括40例缺血性伴明显瘢痕组织、40例非缺血性心肌病、40例任何心肌改变(尤其LGE序列),将FLORA性能与放射科医生评估比较。
诊断标准与关键数值
- 双高斯拟合法识别缺血性和非缺血性心肌病变80/80,敏感度100%、特异度98.8%;固定位移法79/80,敏感度55%、特异度50%;缺血性心肌损伤分类正确率85%-95%。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Today there is a growing interest in the quantification of late gadolinium enhancement (LGE) in ischemic and non-ischemic cardiac pathologies. We build an automatic self-made free software FLORA (For Late gadOlinium enhanced aReas clAssification) for the recognition, classification and quantification of LGE areas that allows to improve the observer's performances and that homogenizes the evaluations between different operators.
MATERIAL AND METHODS: We have retrospectively selected 120 CMR exams: 40-ischemic with evident scar tissue on LGE sequences; 40-non-ischemic cardiomyopathy; 40-any myocardial alteration on CMR, especially on LGE sequences. FLORA's performance was compared to the radiologist's evaluation.
RESULTS: FLORA identified both ischemic and non-ischemic myocardial lesions in almost all cases (80/80 and 79/80 for the double-Gaussian fit method and fixed-shift method, respectively, with sensitivity and specificity of 100%/98.8% and 55%/50%, respectively). The best results were obtained from the classification of ischemic myocardial damage, which was correctly identified in 85%-95% of cases. FLORA also increases the agreement between observers and allows a quantitative evaluation of transmurality.
CONCLUSIONS: FLORA has proven to be an applicable tool that improves and facilitates the classification of LGE areas allowing their quantification.