文献速递骨肌MR

三维T1ρ成像定量评估开放楔形胫骨高位截骨术后软骨的初步研究

A pilot study with 3D T1ρ-mapping for quantitative evaluation of cartilage after open-wedge high tibial osteotomy.
PubMed 文献 · Eur J Radiol · 2022-04-09

本研究纳入11例内侧膝骨关节炎及股骨内侧髁自发性骨坏死患者,在开放楔形胫骨高位截骨术前及取内固定后行T1ρ磁共振成像,比较二维与三维分析测得的T1ρ值。三维分析显示股骨内侧髁术后T1ρ值较术前显著降低(44.1 ms 对 38.9 ms,p=0.016),且与关节镜ICRS分级呈正相关(rs=0.62,p<0.01),二维分析未显示显著差异。作者认为三维T1ρ成像可能是检测术后软骨质量变化的有效工具。

要点

  • 三维T1ρ分析显示股骨内侧髁术后T1ρ值较术前显著降低(44.1 ms 对 38.9 ms,p=0.016)。
  • 三维T1ρ值与关节镜ICRS分级术前术后均呈正相关(rs=0.62,p<0.01),二维T1ρ值无此相关性。
  • 82%的患者股骨内侧髁可见软骨修复,但二维分析各部位术后均无显著差异。

核心结论

  • 三维T1ρ成像可能是检测开放楔形胫骨高位截骨术后软骨质量变化的有效工具。

研究设计与样本

  • 初步研究,纳入11例内侧膝骨关节炎合并股骨内侧髁自发性骨坏死患者,行T1ρ磁共振成像,以关节镜ICRS分级为参考,采用Wilcoxon符号秩检验及Spearman秩相关系数分析。

关键影像表现/征象

  • 股骨内侧髁软骨修复见于高比例患者(82%)。
  • 三维分析示股骨内侧髁T1ρ值术后较术前显著降低(44.1 ms 对 38.9 ms,p=0.016),其余部位术后均无显著差异。
  • 二维分析各部位术后均未显示显著差异。

诊断标准与关键数值

  • 软骨损伤状态采用国际软骨修复学会分级系统(ICRS分级)评估。
  • 三维T1ρ值与关节镜所见在股骨内侧髁术前术后均呈正相关(rs=0.62,p<0.01)。
  • 二维T1ρ值与关节镜所见无相关性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the recently developed three-dimensional (3D) T1ρ-mapping technique for the quantitative evaluation of cartilage changes after open-wedge high tibial osteotomy (OWHTO).

METHOD: Eleven patients with medial knee osteoarthritis and spontaneous osteonecrosis of the medial femoral condyle underwent T1ρ magnetic resonance imaging. The full-thickness cartilage of the medial femoral condyle (MFC), lateral femoral condyle, medial tibial condyle, and lateral tibial condyle, and the trochlea and patella were set as regions of interest; mean T1ρ values were calculated using two-dimensional (2D) and 3D analyses. The state of cartilage injury was evaluated using the International Cartilage Repair Society grading system (ICRS grade). T1ρ values before OWHTO and after hardware removal were compared using the Wilcoxon signed-rank test. The correlation between T1ρ values and the ICRS grade was explored using the Spearman rank correlation coefficient.

RESULTS: Cartilage repair at the MFC was observed in a high proportion of patients (82%), but 2D analysis did not reveal a significant difference after surgery at any site. In contrast, 3D analysis revealed a significant decrease in T1ρ values after surgery at the MFC (before surgery: 44.1 ms; after surgery: 38.9 ms; p = 0.016), but no significant difference at any other site. In the MFC, there was a positive correlation between 3D T1ρ values and arthroscopic findings before and after surgery (rs = 0.62, p < 0.01), which was absent from the 2D T1ρ values.

CONCLUSIONS: 3D T1ρ-mapping may be an effective tool for detecting changes in cartilage quality after OWHTO.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yamasaki, Ogawa, Okamura, et al. A pilot study with 3D T1ρ-mapping for quantitative evaluation of cartilage after open-wedge high tibial osteotomy. Eur J Radiol. 2022. PMID: 35429717. doi:10.1016/j.ejrad.2022.110308

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。