文献速递骨肌神经技术与安全CTMRDR

交通与职业事故后颈椎和腰椎影像学检查:影像技术使用、累积辐射剂量及相关终生癌症风险评估

Cervical and lumbar spine imaging after traffic and occupational accidents: Evaluation of the use of imaging techniques, cumulative radiation dose and associated lifetime cancer risk.
PubMed 文献 · Eur J Radiol · 2022-04-04

研究纳入500例交通或职业事故后患者,统计颈椎和腰椎的X线、CT、MRI检查次数并估算累积有效剂量与终生癌症风险。MRI使用最多(49%),交通事故组平均累积有效剂量4.4 mSv,职业事故组9.4 mSv,无患者超过100 mSv,但19例落入「中等风险」组。

要点

  • 事故后颈椎和腰椎复查中MRI使用最多(1038/2107,49%),其次为X线(631,30%)和CT(438,21%)。
  • 交通事故组平均累积有效剂量4.4 mSv,职业事故组9.4 mSv,无患者累积有效剂量超过100 mSv。
  • 19例患者落入「中等风险」组,即累积辐射所致致死性癌症额外风险在1/1000至1/100之间。

核心结论

  • 轻度或中度交通或职业事故后重复影像检查的累积有效剂量均未超过100 mSv,但19例患者落入辐射诱发癌症的「中等风险」组;追踪辐射暴露可能有助于识别高累积有效剂量者,同时需要对辐射正当使用进行教育。

研究设计与样本

  • 研究队列包含500例交通或职业事故后患者,逐一统计X线、CT和MRI检查数量及损伤严重程度,以典型有效剂量值求和估算累积有效剂量(mSv),并按性别、暴露时年龄和暴露部位的风险系数估算终生癌症总风险及风险分级。

诊断标准与关键数值

  • 共完成2107次影像检查,其中X线631次(30%)、CT 438次(21%)、MRI 1038次(49%);除1例外所有病例简明损伤定级(Abbreviated Injury Scale)均为1-2级。

临床应用与阅片要点

  • 作者认为追踪辐射暴露可能有助于识别累积有效剂量高的患者,同时需要对辐射的正当使用进行教育。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To study number and type of imaging techniques, cumulative radiation exposure and radiation-induced risk from repeated imaging of cervical and lumbar spine attained after traffic or occupational accident.

METHOD: The study cohort comprised of 500 patients after traffic or occupational accident. Amount of radiography, CT and MRI procedures and injury severity were tallied for each patient. Cumulative effective dose (CED), expressed in millisieverts (mSv), was estimated by summing up typical effective dose values. Total lifetime cancer risks and associated risk category were estimated by using risk coefficients, specified according to sex, age at exposure and exposed region.

RESULTS: A total of 2,107 imaging procedures were performed of which 30% were radiographs (n = 631), 21% were CT (n = 438) and 49% were MRI (n = 1,038). Abbreviated Injury Scale was low (1-2) in all cases (except one). The cohort included 352 patients after traffic accident and 148 after occupational accident. Mean CED of these two groups were 4.4 mSv and 9.4 mSv, respectively. No patient had a CED higher than 100 mSv. Nineteen patients fell into the 'moderate risk' group, meaning that the additional risk of fatal cancer from accumulated radiation exposure lies between 1 in 1,000 and 1 in 100.

CONCLUSIONS: MRI was the most used imaging technique. No CED from repeated imaging procedures after minor or moderate traffic or occupational accident exceeded 100 mSv. However, nineteen patients fell into the 'moderate risk' group of developing radiation-induced cancer. Tracking radiation exposure can be beneficial in identifying those with high CED, although education on its proper use is necessary.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. De Roo, Bacher, Verstraete, et al. Cervical and lumbar spine imaging after traffic and occupational accidents: Evaluation of the use of imaging techniques, cumulative radiation dose and associated lifetime cancer risk. Eur J Radiol. 2022. PMID: 35429715. doi:10.1016/j.ejrad.2022.110293

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。