文献速递腹部外周血管MR

应用4D flow MRI表征肠系膜与门静脉血流动力学:进餐及昼夜变化的影响

Characterization of mesenteric and portal hemodynamics using 4D flow MRI: the effects of meals and diurnal variation.
PubMed 文献 · Abdom Radiol (NY) · 2022-04-13

本研究用3 T 4D flow MRI在7名健康对照和7名门静脉高压患者中量化门静脉及内脏血管血流,评估进餐、一日中不同时间及隔日重复扫描的变异。健康对照早餐后门静脉、肠系膜上静脉、肠系膜上动脉、肝动脉及腹腔干血流显著增加,午餐后仅腹腔干、肠系膜上动脉、肠系膜上静脉及门静脉有显著反应;肝硬化患者对进餐的反应总体减低,且门静脉血流在下午最高。

要点

  • 4D flow MRI可在3 T下以1.25 mm各向同性真实空间分辨率量化门静脉及肠系膜血流。
  • 健康对照对早餐的血流反应涉及门静脉、肠系膜上静脉、肠系膜上动脉、肝动脉及腹腔干,对午餐仅腹腔干、肠系膜上动脉、肠系膜上静脉及门静脉有显著反应。
  • 肝硬化患者对进餐的血流反应总体较健康对照减低,门静脉血流在下午最高。

核心结论

  • 研究用4D flow MRI表征了进餐、一日中不同时间及隔日变异对肝硬化和健康对照门静脉与肠系膜血流动力学的影响。

研究设计与样本

  • 经IRB批准、符合HIPAA的研究,纳入7名健康对照和7名门静脉高压患者,在3 T MRI使用32通道体线圈、大容积覆盖、1.25 mm各向同性真实空间分辨率采集,以L/min量化肝及内脏血管血流。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine the variability of blood flow measurements using 4D flow MRI in the portal and mesenteric circulations and to characterize the effects of meal ingestion, time of day, and between-day (diurnal) variations on portal and mesenteric hemodynamics.

METHODS: In this IRB-approved and HIPAA-compliant study, 7 healthy and 7 portal hypertension patients imaged. MRI exams were conducted at 3 T using a 32-channel body coil with large volumetric coverage and 1.25-mm isotropic true spatial resolution. Blood flow was quantified (L/min) in the hepatic and splanchnic vasculature. The first MR scan was performed after at least 8 h of fasting. Subsequently, subjects ingested 574 mL EnSure Plus® orally. A second acquisition was started 20 min after the meal ingestion. A third scan was performed before lunch and a fourth acquisition took place 20 min after lunch. A fifth scan was performed around 4 pm. Finally, subjects returned one week later for a repeat morning visit, with identical conditions as the first visit.

RESULTS: In healthy controls significant increase in blood flow was seen in the PV, SMV, SMA, HA, and SCAo in response to breakfast but only the SCAo, SMA, SMV, and PV had a significant response to lunch. In general, patients with cirrhosis showed reduced response to meals compared to that in healthy controls. Additionally, PV flow in patients had the highest value in the afternoon.

CONCLUSION: Effects of meal ingestion, time of day, and between-day variations were characterized using Radial 4D flow MRI in patients with cirrhosis and healthy controls.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Roldán-Alzate, Campo, Mao, et al. Characterization of mesenteric and portal hemodynamics using 4D flow MRI: the effects of meals and diurnal variation. Abdom Radiol (NY). 2022. PMID: 35419747. doi:10.1007/s00261-022-03513-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。