文献速递心血管胸部CT

一种用于冠状动脉钙化积分评估中超低剂量胸部CT去噪的深度学习方法

A deep-learning method for the denoising of ultra-low dose chest CT in coronary artery calcium score evaluation.
PubMed 文献 · Clin Radiol · 2022-04-09

前瞻性纳入60例成人患者,同期行常规剂量CT(NDCT)与超低剂量CT(ULDCT),采用全卷积神经网络对ULDCT去噪。去噪后图像信噪比提高27.7%(p<0.001),去噪ULDCT(DULDCT)识别有无冠状动脉钙化的准确度达98-100%,高于ULDCT的92%。

要点

  • 去噪使超低剂量胸部CT信噪比提高27.7%(p<0.001)。
  • ULDCT与DULDCT的钙化积分均低于NDCT(p≤0.001)。
  • DULDCT识别有无冠状动脉钙化的准确度为98-100%,高于ULDCT的92%。

核心结论

  • DULDCT显著降低图像噪声,较原始ULDCT更好地识别无冠状动脉钙化的患者。

研究设计与样本

  • 前瞻性研究,2017年9月至2017年12月纳入60例成人患者,同期行NDCT与ULDCT,最终59例纳入分析(中位年龄67岁,58%为男性);采用带批归一化的全卷积神经网络学习ULDCT真实噪声特征并去噪,由两名盲法放射科医师评估NDCT、ULDCT与DULDCT的钙化积分。

关键影像表现/征象

  • 去噪使信噪比提高27.7%(p<0.001)。
  • ULDCT与DULDCT的钙化积分均低于NDCT(p≤0.001)。

诊断标准与关键数值

  • 两名读者间观察者一致性几乎完美(组内相关系数>0.993)。
  • 区分有无冠状动脉钙化时,DULDCT准确度98-100%、阳性似然比14.29至>99;ULDCT准确度92%、阳性似然比2.78。
  • 钙化积分分类以高于或低于100分以及钙化存在(评分0 vs >0)进行判定。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate a novel deep-learning denoising method for ultra-low dose CT (ULDCT) in the assessment of coronary artery calcium score (CACS).

MATERIALS AND METHODS: Sixty adult patients who underwent two unenhanced chest CT examinations, a normal dose CT (NDCT) and an ULDCT, were enrolled prospectively between September 2017 to December 201. A special training set was created to learn the characteristics of the real noise affecting the ULDCT implementing a fully convolutional neural network with batch normalisation. Subsequently, the 60 ULDCTs of the evaluation set were denoised. Two blinded radiologists assessed the NDCT, ULDCT, and denoised-ULDCT (DULDCT), assigning a CACS and categorised each scan as having a score above or below 100 and presence of calcifications (score 0 versus >0). Statistical analysis was used to evaluate the agreement between the readers and differences in CACSs between each imaging method.

RESULTS: After excluding one patient, the cohort included 59 patients (median age 67 years, 58% men). The ULDCT median effective radiation dose (ERD) was 0.172 mSv, which was 2.8% of the NDCT median ERD. Denoising improved the signal-to-noise ratio by 27.7% (p<0.001). Interobserver agreement was almost perfect between readers (intraclass correlation coefficient >0.993). CACSs were lower for ULDCT and DULDCT as compared to the NDCT (p ≤ 0.001). In differentiating between the presence and absence of coronary artery calcifications, DULDCT showed greater accuracy (98-100%) and positive likelihood ratio (14.29->99) compared to ULDCT (92% and 2.78, respectively).

CONCLUSION: DULCT significantly reduced the image noise and better identified patients with no coronary artery calcifications than native ULDCT.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Klug, Shemesh, Green, et al. A deep-learning method for the denoising of ultra-low dose chest CT in coronary artery calcium score evaluation. Clin Radiol. 2022. PMID: 35414431. doi:10.1016/j.crad.2022.03.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。