新生儿多普勒在婴儿心脏导管插入术和心脏手术中检测脑高信号短暂信号
本研究纳入15例接受经导管介入和13例接受心脏手术的先天性心脏病婴儿,使用NeoDoppler经囟门连续监测脑血流,手动检测高信号短暂信号(HITS)。共检测到1169个HITS,中位栓塞物-血液比(EBR)为9.74 dB;手术组HITS中位数45个,经导管组12个。研究检测到频繁HITS,并确定NeoDoppler监测用于HITS检测的可行性。
要点
- 婴儿心脏手术和经导管介入中可频繁检测到脑HITS,手术组中位数45个,经导管组12个。
- HITS以栓塞信号为特征,在彩色M型多普勒上可见,并伴有Doppler频谱强度增高。
- NeoDoppler经囟门连续监测脑血流用于HITS检测是可行的。
核心结论
- 在婴儿心脏手术和经导管介入中检测到频繁的HITS,并确定使用NeoDoppler监测进行HITS检测的可行性。
研究设计与样本
- 纳入先天性心脏病婴儿,经导管介入组15例,心脏手术组13例,使用基于平面波发射的NeoDoppler非侵入性超声系统经囟门连续监测脑血流,显示24个采样容积的彩色M型多普勒和Doppler频谱。
关键影像表现/征象
- HITS基于彩色M型多普勒中的栓塞信号手动检测,并在Doppler频谱中对应强度增高。
- 共检测到1169个HITS,中位EBR为9.74 dB(IQR:5.10-15.80 dB)。
- 心脏手术组HITS中位数为45个(IQR:11-150),经导管组中位数为12个(IQR:7-24)。
- 心脏手术期间,从体外循环开始到主动脉阻断期间每小时HITS数量最高。
诊断标准与关键数值
- HITS定义为彩色M型多普勒中的栓塞信号并伴有Doppler频谱对应强度增高。
- HITS大小由栓塞物-血液比(EBR)定义,本研究中位EBR为9.74 dB(IQR:5.10-15.80 dB)。
临床应用与阅片要点
- NeoDoppler经囟门连续监测可用于婴儿心脏手术和经导管介入中检测HITS。
- 阅片时注意彩色M型多普勒上的栓塞信号及Doppler频谱的强度增高,以识别HITS。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
There is a risk of gaseous and solid micro-embolus formation during transcatheter cardiac interventions and surgery in children with congenital heart disease (CHD). Our aim was to study the burden of high-intensity transient signals (HITS) during these procedures in infants. We used a novel color M-mode Doppler (CMD) technique by NeoDoppler, a non-invasive ultrasound system based on plane wave transmissions for transfontanellar continuous monitoring of cerebral blood flow in infants. The system displays CMD with 24 sample volumes and a Doppler spectrogram. Infants with CHD undergoing transcatheter interventions (n = 15) and surgery (n = 13) were included. HITS were manually detected based on an "embolic signature" in the CMD with corresponding intensity increase in the Doppler spectrogram. Embolus-to-blood ratio (EBR) defined HITS size. A total of 1169 HITS with a median EBR of 9.74 dB (interquartile range [IQR]: 5.10-15.80 dB) were detected. The median number of HITS in the surgery group was 45 (IQR: 11-150), while in the transcatheter group the median number was 12 (IQR: 7-24). During cardiac surgery, the highest number of HITS per hour was seen from initiation of cardiopulmonary bypass to aortic X-clamp. In this study we detected frequent HITS and determined the feasibility of using NeoDoppler monitoring for HITS detection.
引用
- Leth-Olsen, Døhlen, Torp, et al. Detection of Cerebral High-Intensity Transient Signals by NeoDoppler during Cardiac Catheterization and Cardiac Surgery in Infants. Ultrasound Med Biol. 2022. PMID: 35410742. doi:10.1016/j.ultrasmedbio.2022.02.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。