文献速递技术与安全CT

以T恤尺码作为计算机断层扫描(CT)中体型分类并制定不同检查类型的基于尺寸的剂量参考水平

T-shirt size as a classification for body habitus in computed tomography (CT) and development of size-based dose reference levels for different indications.
PubMed 文献 · Eur J Radiol · 2022-04-04

研究基于美国256家CT机构的约93万例成人身体CT检查,按有效直径将每次采集分为XXS至XXL七种T恤尺码,分析患者尺寸对剂量指数的影响,并为20种身体CT检查制定各尺码的CTDIvol、SSDE和DLP的50th和75th百分位参考水平。

要点

  • 以M尺码为参考,XXS患者CTDIvol约为M的60%,XXL约为210%。
  • SSDE随T恤尺码的变化幅度小于CTDIvol,但不同尺码间SSDE仍有近40%至220%的差异。
  • 已为20种身体CT检查的各七种T恤尺码提供CTDIvol、SSDE和DLP的50th与75th百分位值。

核心结论

  • 以T恤尺码表达体型简单直观,可提供不同体型患者间剂量指标差异的认知工具。

研究设计与样本

  • 基于美国256家CT机构约93万例成人身体CT检查的剂量指数分析,按有效直径将每次采集分为XXS、XS、S、M、L、XL、XXL七种尺码,并制定20种身体CT检查(涵盖常规和器官特异性临床指征)的基于尺寸的参考水平(50th和75th百分位)。

诊断标准与关键数值

  • 以T恤尺码M为参考,其他尺码的CTDIvol为:XXS约60%、XS约65%、S约75%、L约130%、XL约165%、XXL约210%。
  • 体型很小的患者接受的剂量约为M尺码患者的60%,XXL尺码所需剂量为M尺码的两倍。
  • 最大与最小尺码的剂量指数比值显示,SSDE的变异(约50%)远小于CTDIvol,但不同T恤尺码间SSDE仍有近40%至220%的变异。
  • 针对20种CT检查和七种T恤尺码分别给出了CTDIvol、SSDE和DLP的50th和75th百分位值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To examine the impact of patient size on dose indices and develop size-based reference levels (50th and 75th percentiles) for 20 body CT exams for routine and organ-specific clinical indications.

METHODS: Based on effective diameter estimated from adult body CT, each acquisition was classified into T-shirt size as XXS, XS, S, M, L, XL, and XXL. Radiation dose indices for each size and each exam type were correlated.

RESULTS: About 0.93 million CT exams from 256 CT facilities in the United States were analysed. Taking T-shirt size M as a reference, the CTDIvol for other sizes were: XXS (∼60%), XS (∼65%), S (∼75%), L (∼130%), XL (∼165%), XXL (∼210%), or grossly small patients received about 60% of the dose as compared to M sized patients and XXL required doubling the dose. Taking ratio of the dose indices of the largest to smallest size, it was evident that SSDE variation was much less (about 50%) than that in CTDIvol, but there was still nearly 40 to 220% variation in SSDE across the range of t-shirt sizes. The 50th and 75th percentile values are presented for CTDIvol, SSDE and DLP for each of the 20 CT exams and for each of the seven T-shirt sizes.

CONCLUSIONS: A novel approach expressing body habitus in terms of T-shirt size is not only simple and intuitive, but it also provides a tool to have a perception of differences in dose metrices among patients of different body build.

来源:Eur J Radiol,查看原文。版权归原作者所有。