基于深度学习的算法提高放射科医生在CT上检测骨转移的表现
这项回顾性单中心研究开发并评估了用于CT自动检测骨转移的深度学习算法(DLA),训练集纳入269例阳性扫描(含1375处骨转移)和463例阴性扫描。验证集DLA敏感度89.8%(44/49),每例0.775个假阳性;测试集敏感度82.7%(62/75),每例0.617个假阳性。9名放射科医生在DLA辅助下,加权AFROC FOM从0.746提升至0.899(p < .001),平均判读时间从168秒降至85秒(p = .004)。
要点
- DLA辅助使9名放射科医生的加权AFROC FOM从0.746提升至0.899(p < .001)。
- DLA辅助使每例平均判读时间从168秒降至85秒(p = .004)。
- DLA在验证集敏感度89.8%(44/49),每例0.775个假阳性;测试集敏感度82.7%(62/75),每例0.617个假阳性。
核心结论
- 在DLA辅助下,放射科医生检测骨转移的整体表现提升,同时判读时间减少。
研究设计与样本
- 回顾性研究,收集2009年至2019年单一机构CT扫描,训练集269例阳性扫描(含1375处骨转移)和463例阴性扫描;另收集50例阳性与50例阴性扫描按2:3分为验证集和测试集;由委员会认证的放射科医生进行观察者研究,采用Jackknife替代自由响应受试者工作特征分析评估观察者表现。
诊断标准与关键数值
- 验证集DLA敏感度89.8%(44/49),每例0.775个假阳性。
- 测试集DLA敏感度82.7%(62/75),每例0.617个假阳性。
- 9名放射科医生加权AFROC FOM从0.746提升至0.899(p < .001)。
- 每例平均判读时间从168秒降至85秒(p = .004)。
临床应用与阅片要点
- 原文结论为DLA辅助可提升放射科医生骨转移检测整体表现并减少判读时间。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To develop and evaluate a deep learning-based algorithm (DLA) for automatic detection of bone metastases on CT.
METHODS: This retrospective study included CT scans acquired at a single institution between 2009 and 2019. Positive scans with bone metastases and negative scans without bone metastasis were collected to train the DLA. Another 50 positive and 50 negative scans were collected separately from the training dataset and were divided into validation and test datasets at a 2:3 ratio. The clinical efficacy of the DLA was evaluated in an observer study with board-certified radiologists. Jackknife alternative free-response receiver operating characteristic analysis was used to evaluate observer performance.
RESULTS: A total of 269 positive scans including 1375 bone metastases and 463 negative scans were collected for the training dataset. The number of lesions identified in the validation and test datasets was 49 and 75, respectively. The DLA achieved a sensitivity of 89.8% (44 of 49) with 0.775 false positives per case for the validation dataset and 82.7% (62 of 75) with 0.617 false positives per case for the test dataset. With the DLA, the overall performance of nine radiologists with reference to the weighted alternative free-response receiver operating characteristic figure of merit improved from 0.746 to 0.899 (p < .001). Furthermore, the mean interpretation time per case decreased from 168 to 85 s (p = .004).
CONCLUSION: With the aid of the algorithm, the overall performance of radiologists in bone metastases detection improved, and the interpretation time decreased at the same time.
KEY POINTS: • A deep learning-based algorithm for automatic detection of bone metastases on CT was developed. • In the observer study, overall performance of radiologists in bone metastases detection improved significantly with the aid of the algorithm. • Radiologists' interpretation time decreased at the same time.
引用
- Noguchi, Nishio, Sakamoto, et al. Deep learning-based algorithm improved radiologists' performance in bone metastases detection on CT. Eur Radiol. 2022. PMID: 35394186. doi:10.1007/s00330-022-08741-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。