基于计算机断层扫描影像组学的胃癌微卫星不稳定状态术前预测:多中心研究
本研究回顾性收集2015年1月至2021年8月189例胃癌患者术前腹部增强CT,分为训练集90例与外部验证集99例,构建影像组学模型预测微卫星不稳定状态;训练集AUC为0.8228,外部验证集AUC为0.7603,显示模型具有一定的泛化能力,肿瘤部位与年龄有统计学意义,MSI-H多见于胃窦及高龄患者。
要点
- 基于CT影像组学特征联合临床特征构建的模型可用于术前无创预测胃癌微卫星不稳定状态。
- 模型在训练集AUC为0.8228,外部验证集AUC为0.7603。
- MSI-H胃癌多见于胃窦及高龄患者,肿瘤部位和年龄有统计学意义(p<0.05)。
核心结论
- 基于CT图像和临床特征的影像组学标志物有潜力作为术前评估胃癌MSI状态的无创辅助诊断工具,可辅助临床决策并改善患者结局。
研究设计与样本
- 回顾性收集189例胃癌患者术前上腹部或全腹部增强CT,患者术后行胃癌MSI状态检测,影像与临床病理数据日期为2015年1月至2021年8月,分为训练集90例和外部验证集99例。
诊断标准与关键数值
- 训练集按MSI状态分为MSI-H组30例和MSI-L/S组60例,外部验证集MSI-H组33例和MSI-L/S组66例。
- 影像组学模型训练集AUC为0.8228(95%CI 0.7355-0.9101),外部验证集AUC为0.7603(95%CI 0.6625-0.8581)。
- 训练集准确度0.72、敏感度0.63、特异度0.77;外部验证集准确度0.67、敏感度0.79、特异度0.60。
- 肿瘤部位和年龄在临床数据统计分析中有统计学意义(p<0.05),MSI-H胃癌多见于胃窦和高龄患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To construct and validate a radiomics feature model based on computed tomography (CT) images and clinical characteristics to predict the microsatellite instability (MSI) status of gastric cancer patients before surgery.
METHODS: We retrospectively collected the upper abdominal or the entire abdominal-enhanced CT scans of 189 gastric cancer patients before surgery. The patients underwent postoperative gastric cancer MSI status testing, and the dates of their radiologic images and clinicopathological data were from January 2015 to August 2021. These 189 patients were divided into a training set (n = 90) and an external validation set (n = 99). The patients were divided by MSI status into the MSI-high (H) arm (30 and 33 patients in the training set and external validation set, respectively) and MSI-low/stable (L/S) arm (60 and 66 patients in the training set and external validation set, respectively). In the training set, the clinical characteristics and tumor radiologic characteristics of the patients were extracted, and the tenfold cross-validation method was used for internal validation of the training set. The external validation set was used to assess its generalized performance. A receiver-operating characteristic (ROC) curve was plotted to assess the model performance, and the area under the curve (AUC) was calculated.
RESULTS: The AUC of the radiomics model in the training set and external validation set was 0.8228 [95% confidence interval (CI) 0.7355-0.9101] and 0.7603 [95% CI 0.6625-0.8581], respectively, showing that the constructed radiomics model exhibited satisfactory generalization capabilities. The accuracy, sensitivity, and specificity of the training dataset were 0.72, 0.63, and 0.77, respectively. The accuracy, sensitivity, and specificity of the external validation dataset were 0.67, 0.79, and 0.60, respectively. Statistical analysis was carried out on the clinical data, and there was statistical significance for the tumor site and age (p < 0.05). MSI-H gastric cancer was mostly seen in the gastric antrum and older patients.
CONCLUSIONS: Radiomics markers based on CT images and clinical characteristics have the potential to be a non-invasive auxiliary diagnostic tool for preoperative assessment of gastric cancer MSI status, and they can aid in clinical decision-making and improve patient outcomes.
引用
- Liang, Wu, Liu, et al. A multicenter study on the preoperative prediction of gastric cancer microsatellite instability status based on computed tomography radiomics. Abdom Radiol (NY). 2022. PMID: 35391567. doi:10.1007/s00261-022-03507-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。