文献速递儿科影像技术与安全MRUS

儿童李-佛美尼综合征早期肿瘤检测影像方法的诊断准确性

Diagnostic accuracy of imaging approaches for early tumor detection in children with Li-Fraumeni syndrome.
PubMed 文献 · Pediatr Radiol · 2022-04-08

该研究对31例李-佛美尼综合征患儿按多伦多方案采集的影像进行盲法回顾性阅片,以病理、专用或后续随访影像及临床结局为参考标准,按研究或病灶计算各模态诊断效能;瘤灶总体真阳性仅4例(0.7%),全身MRI骨骼/软组织敏感度40.0%、特异度38.2%,脑MRI敏感度50.0%、特异度93.8%,胸部和腹部区域全身MRI及腹部/盆腔US特异度高但敏感度不可用或未报告;作者提出优化成像方案、明确异常标准、建立结构化报告和共识双读可能提高监测诊断准确性。

要点

  • 31例患儿763项研究/病灶中仅4例(0.7%)真阳性,其中全身MRI 3例、脑MRI 1例。
  • 全身MRI骨骼/软组织最差情况分析敏感度40.0%(95%CI 7.3%,83.0%)、特异度38.2%(95%CI 29.2%,48.0%)。
  • 脑MRI敏感度50.0%(95%CI 2.7%,97.3%)、特异度93.8%(95%CI 85.6%,97.7%)。

核心结论

  • 按多伦多方案用于儿童李-佛美尼综合征监测的影像,其早期肿瘤检测诊断准确性有限,作者认为优化成像方案、明确异常判定标准、建立结构化报告及共识双读可能提升诊断准确性。

研究设计与样本

  • 盲法回顾性影像阅片研究,纳入31例儿童患者,以组织病理学诊断、相应专用或后续监测影像或临床结局为参考标准。

诊断标准与关键数值

  • 按研究计算:胸部区域全身MRI(n=115)敏感度不可用、特异度97.8%(95%CI 91.4%,99.6%)。
  • 按研究计算:腹部区域全身MRI(n=115)敏感度100.0%(95%CI 5.5%,100.0%)、特异度96.8%(95%CI 90.2%,99.2%)。
  • 按研究计算:腹部/盆腔US(n=292)敏感度不可用、特异度98.3%(95%CI 95.3,99.4)。
  • 按研究计算:脑MRI(n=101)敏感度50.0%(95%CI 2.7%,97.3%)、特异度93.8%(95%CI 85.6%,97.7%)。
  • 按病灶计算:全身MRI骨骼/软组织(n=140)敏感度40.0%(95%CI 7.3%,83.0%)、特异度38.2%(95%CI 29.2%,48.0%)。

临床应用与阅片要点

  • 作者认为考虑优化成像方案、明确异常判定标准、建立结构化报告系统及开展共识双读,可能提高肿瘤监测的诊断准确性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The Toronto protocol for cancer surveillance in children with Li-Fraumeni syndrome has been adopted worldwide.

OBJECTIVE: To assess the diagnostic accuracy of the imaging used in this protocol.

MATERIALS AND METHODS: We conducted a blinded retrospective review of imaging modalities in 31 pediatric patients. We compared imaging findings with the reference standards, which consisted of (1) histopathological diagnosis, (2) corresponding dedicated imaging or subsequent surveillance imaging or (3) clinical outcomes. We individually analyzed each modality's diagnostic performance for cancer detection and assessed it on a per-study basis for chest and abdominal regional whole-body MRI (n=115 each), brain MRI (n=101) and abdominal/pelvic US (n=292), and on a per-lesion basis for skeleton/soft tissues on whole-body MRI (n=140).

RESULTS: Of 763 studies/lesions, approximately 80% had reference standards that identified 4 (0.7%) true-positive, 523 (85.3%) true-negative, 5 (0.8%) false-positive, 3 (0.5%) false-negative and 78 (12.7%) indeterminate results. There were 3 true-positives on whole-body MRI and 1 true-positive on brain MRI as well as 3 false-negatives on whole-body MRI. Sensitivities and specificities of tumor diagnosis using a worst-case scenario analysis were, respectively, 40.0% (95% confidence interval [CI]: 7.3%, 83.0%) and 38.2% (95% CI: 29.2%, 48.0%) for skeleton/soft tissues on whole-body MRI; sensitivity non-available and 97.8% (95% CI: 91.4%, 99.6%) for chest regional whole-body MRI; 100.0% (95% CI: 5.5%, 100.0%) and 96.8% (95% CI: 90.2%, 99.2%) for abdominal regional whole-body MRI; sensitivity non-available and 98.3% (95% CI: 95.3, 99.4) for abdominal/pelvic US; and 50.0% (95% CI: 2.7%, 97.3%) and 93.8% (95% CI: 85.6%, 97.7%) for brain MRI.

CONCLUSION: Considerations for optimizing imaging protocol, defining criteria for abnormalities, developing a structured reporting system, and practicing consensus double-reading may enhance the diagnostic accuracy for tumor surveillance.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Tewattanarat, Junhasavasdikul, Panwar, et al. Diagnostic accuracy of imaging approaches for early tumor detection in children with Li-Fraumeni syndrome. Pediatr Radiol. 2022. PMID: 35391548. doi:10.1007/s00247-022-05296-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。