深度学习重建对多期肝脏CT辐射剂量优化潜力的临床与体模研究
本研究通过体模与临床两部分评估深度学习重建(DLR)对多期肝脏CT图像质量及辐射剂量优化能力。体模中DLR在5.3 mGy与7.3 mGy的对比度可检测性略高于标准剂量18.0 mGy的混合迭代重建(HIR)。临床回顾性分析73例患者,低剂量DLR较标准剂量HIR在SSDE降低52.8%时仍获更低噪声、更高CNR及更高主观评分。
要点
- 体模中DLR在5.3 mGy与7.3 mGy的对比度可检测性略高于标准剂量18.0 mGy的HIR。
- 临床低剂量DLR较标准剂量HIR的SSDE降低52.8%(8.0±2.5 vs 16.8±3.4 mGy)。
- 低剂量DLR图像噪声更低、CNR更高,所有主观评分均高于标准剂量HIR(均p≤0.05)。
核心结论
- 与HIR技术相比,DLR可改善多期肝脏CT的主客观图像质量,即使在约一半辐射剂量下亦如此。
研究设计与样本
- 临床与体模研究:体模采用物理评估体模,在5.3至18.0 mGy范围内五个SSDE值下基于噪声功率谱与任务传递函数计算高、低对比度可检测性;临床回顾性分析73例在平均约四个月间隔内接受标准剂量与低剂量多期肝脏CT的患者,标准剂量图像用HIR重建,低剂量图像用HIR与DLR重建。
诊断标准与关键数值
- 体模中DLR在5.3 mGy的高对比度可检测性与7.3 mGy的低对比度可检测性均略高于标准剂量18.0 mGy的HIR。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This clinical and phantom study aimed to evaluate the impact of deep learning-based reconstruction (DLR) on image quality and its radiation dose optimization capability for multiphase hepatic CT relative to hybrid iterative reconstruction (HIR).
METHODS: Task-based image quality was assessed with a physical evaluation phantom; the high- and low-contrast detectability of HIR and DLR images were computed from the noise power spectrum and task-based transfer function at five different size-specific dose estimate (SSDE) values in the range 5.3 to 18.0-mGy. For the clinical study, images of 73 patients who had undergone multiphase hepatic CT under both standard-dose (STD) and lower-dose (LD) examination protocols within a time interval of about four-months on average, were retrospectively examined. STD images were reconstructed with HIR, while LD with HIR (LD-HIR) and DLR (LD-DLR). SSDE, quantitative image noise, and contrast-to-noise ratio (CNR) were compared between protocols. The noise magnitude, noise texture, streak artifact, image sharpness, interface smoothness, and overall image quality were subjectively rated by two independent radiologists.
RESULTS: In phantom study, the high- and low-contrast detectability of DLR images obtained at 5.3-mGy and 7.3-mGy, respectively, were slightly higher than those obtained with HIR at the STD protocol dose (18.0-mGy). In clinical study, LD-DLR yielded lower image noise, higher CNR, and higher subjective scores for all evaluation criteria than STD (all, p ≤ 0.05), despite having 52.8% lower SSDE (8.0 ± 2.5 vs. 16.8 ± 3.4-mGy).
CONCLUSIONS: DLR improved the subjective and objective image quality of multiphase hepatic CT compared with HIR techniques, even at approximately half the radiation dose.
引用
- Nagayama, Goto, Sakabe, et al. Radiation dose optimization potential of deep learning-based reconstruction for multiphase hepatic CT: A clinical and phantom study. Eur J Radiol. 2022. PMID: 35381567. doi:10.1016/j.ejrad.2022.110280
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。