文献速递骨肌MR

常规MRI来源的软骨下骨小梁生物标志物与膝关节软骨体积丢失的关联:骨关节炎倡议的纵向分析

Conventional MRI-derived subchondral trabecular biomarkers and their association with knee cartilage volume loss as early as 1 year: a longitudinal analysis from Osteoarthritis Initiative.
PubMed 文献 · Skeletal Radiol · 2022-04-02

基于FNIH骨关节炎生物标志物联盟600名受试者的数据,评估基线常规MRI(中间加权序列)测量的软骨下骨小梁厚度(cTbTh)和骨体积分数(cBV/TV)与12、24个月膝关节软骨体积丢失的关联。结果显示较高的内侧cTbTh和cBV/TV与12个月及24个月内侧胫骨软骨体积丢失风险增加相关,未观察到与外侧或股骨侧软骨丢失的显著关联。

要点

  • 常规MRI中间加权序列可测量软骨下骨小梁厚度(cTbTh)和骨体积分数(cBV/TV)。
  • 较高的内侧cTbTh和cBV/TV与12个月及24个月内侧胫骨软骨体积丢失风险增加相关。
  • 内侧骨小梁标志物与外侧胫骨或股骨(内/外侧)软骨体积丢失无显著关联。

核心结论

  • 常规MRI来源的软骨下骨小梁生物标志物(较高的内侧cTbTh和cBV/TV)可能与最早1年内的内侧胫骨软骨体积丢失增加相关。

研究设计与样本

  • 骨关节炎倡议(OAI)内嵌套的病例对照研究,纳入FNIH骨关节炎生物标志物联盟600名受试者,基线采用中间加权(IW)序列MRI评估cTbTh和cBV/TV,参考标准为基线、12个月和24个月膝关节MRI测量的内、外侧软骨体积。

临床应用与阅片要点

  • 使用常规MRI中间加权序列测量内侧软骨下骨小梁cTbTh和cBV/TV,可能有助于识别最早1年内内侧胫骨软骨体积丢失风险较高的受试者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To study associations between MRI-derived subchondral trabecular biomarkers obtained from conventional MRI sequences and knee cartilage loss over 12 and 24 months, using the FNIH osteoarthritis (OA) biomarkers consortium.

MATERIALS AND METHODS: Data of the 600 subjects in the FNIH OA biomarkers consortium (a nested case-control study within Osteoarthritis Initiative [OAI]) were extracted from the online database. Baseline knee MRI (intermediate-weighted (IW) sequences) were evaluated to determine conventional MRI-derived trabecular thickness (cTbTh) and bone-to-total ratio (cBV/TV). The measurements for medial and lateral volumes of cartilages using baseline, 12-, and 24-month knee MRI were extracted from the OAI database, and cartilage volume loss over 12 and 24 months of follow-up were determined using Relative Change Index. The association between conventional MRI-based subchondral trabecular biomarkers and cartilage volume loss were studied using logistic regression models, adjusted for relevant confounders including age, sex, body mass index (BMI), vitamin D use, Kellgren Lawrence grade (KLG), and tibiofemoral alignment.

RESULTS: Higher medial cTbTh and cBV/TV at baseline were associated with increased odds of medial tibial cartilage volume loss over 12 months (ORs: 1.01 [1.00-1.02] and 1.24 [1.10-1.39] per 1-SD change) and 24 months (ORs: 1.01 [1.00-1.02] and 1.22 [1.08-1.37], per 1-SD change). No significant association was observed between medial subchondral trabecular biomarkers and lateral tibial or femoral (medial or lateral) cartilage volume loss over the first and second follow-up years.

CONCLUSIONS: Conventional MRI-derived subchondral trabecular biomarkers (higher medial cTbTh and cBV/TV) may be associated with increased medial tibial cartilage volume loss as early as 1 year.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Pishgar, Ashraf-Ganjouei, Dolatshahi, et al. Conventional MRI-derived subchondral trabecular biomarkers and their association with knee cartilage volume loss as early as 1 year: a longitudinal analysis from Osteoarthritis Initiative. Skeletal Radiol. 2022. PMID: 35366094. doi:10.1007/s00256-022-04042-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。