文献速递儿科影像技术与安全CT

超低剂量儿童C臂锥形束CT中各年龄组的器官剂量与归一化器官剂量

Organ doses and normalized organ doses for various age groups in ultralow dose pediatric C-arm cone-beam CT.
PubMed 文献 · Eur Radiol · 2022-04-02

本研究利用新生儿、1岁、5岁和10岁儿童拟人模体,对最新一代C臂锥形束CT的胸部和腹部采集方案进行个性化蒙特卡罗剂量估算,并与热释光剂量计测量比较。多数器官剂量低于1 mSv,归一化器官剂量从新生儿到10岁儿童递减,蒙特卡罗与热释光剂量计结果差异小于8%。作者认为最新系统儿童C臂锥形束CT多数器官剂量可达亚mGy水平。

要点

  • 儿童C臂锥形束CT胸部与腹部采集时多数器官剂量低于1 mSv。
  • 归一化器官剂量从新生儿至10岁儿童随年龄增长而降低。
  • 蒙特卡罗估算与热释光剂量计实测器官剂量差异小于8%。

核心结论

  • 儿童C臂锥形束CT的归一化器官剂量随年龄变化,最新一代系统在多数器官可实现亚mGy剂量。

研究设计与样本

  • 采用物理拟人模体的剂量学研究,使用模拟新生儿、1岁、5岁和10岁儿童平均个体的四种拟人模体,针对最新一代C臂锥形束CT系统的胸部和腹部采集方案进行个性化蒙特卡罗剂量估算,并与热释光剂量计物理测量比较。

诊断标准与关键数值

  • 胸部采集方案估算皮肤、骨、乳腺、肺、食管、胸腺和心脏的器官剂量。
  • 腹部采集方案估算肝、肾上腺、肾、胰腺、胃、胆囊和脾的器官剂量。
  • 多数器官剂量低于1 mSv,蒙特卡罗与热释光剂量计測量差异小于8%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To estimate organ dose to major radiosensitive organs during pediatric body C-arm CBCT and determine normalized organ doses using a state-of-the-art equipment.

METHODS: This is a study performed utilizing physical anthropomorphic phantoms. Four anthropomorphic phantoms that simulate the average individual as a neonate, 1-year-old, 5-year-old, and 10-year-old child were used. Personalized Monte Carlo (MC)-based dosimetry was performed to estimate organ doses in children referred to thorax and abdomen C-arm CBCT acquisitions on a recently released latest generation C-arm CBCT system. Age-specific normalized organ doses were generated and organ dose was estimated for skin, bone, breast, lungs, esophagus, thymus, and heart, in the thorax, and liver, adrenals, kidneys, pancreas, stomach, gall bladder, and spleen in the abdomen. Estimated doses were compared to corresponding values obtained with physical measurements performed using thermoluminescent dosimeters (TLD).

RESULTS: The results consist of organ doses for thorax and abdomen acquisition protocols. The majority of organs received a dose below 1 mSv. For all ages, the normalized organ doses decreased from neonate to 10-year-old. The difference between the organ doses obtained with MC and TLDs was less than 8%.

CONCLUSIONS: Normalized organ doses in pediatric C-arm CBCT varied with age. Pediatric C-arm CBCT with latest-generation systems may be performed with sub mGy dose for most organs.

KEY POINTS: • The dose to the majority of organs from pediatric C-arm CBCT is in the sub mSv level. • The normalized organ doses decreased from neonate to 10-year-old. • Reported normalized organ doses may be used to estimate organ dose in pediatric C-arm cone-beam CT on modern equipment.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Papadakis, Damilakis. Organ doses and normalized organ doses for various age groups in ultralow dose pediatric C-arm cone-beam CT. Eur Radiol. 2022. PMID: 35364713. doi:10.1007/s00330-022-08767-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。