影像组学可区分儿童幕上胚胎性肿瘤、高级别胶质瘤和室管膜瘤
回顾性多中心队列纳入231例儿童幕上肿瘤患者(胚胎性肿瘤50例、高级别胶质瘤127例、室管膜瘤54例),从T2加权和钆增强T1加权图像提取900个影像组学特征,构建分类器区分肿瘤类型。胚胎性肿瘤与高级别胶质瘤分类器AUC为0.98,高级别胶质瘤与室管膜瘤分类器AUC为0.96,胚胎性肿瘤与室管膜瘤分类器AUC为0.82。
要点
- 胚胎性肿瘤与高级别胶质瘤分类器AUC 0.98,敏感度0.85、特异度0.91。
- 高级别胶质瘤与室管膜瘤分类器AUC 0.96,敏感度0.82、特异度0.94。
- 胚胎性肿瘤与室管膜瘤分类器AUC 0.82,敏感度0.93、特异度0.69。
核心结论
- 多机构研究发现可区分儿童幕上胚胎性肿瘤、高级别胶质瘤和室管膜瘤的影像组学表型,准确度高;将该技术纳入诊断流程可改善诊断、风险分层和治疗计划。
研究设计与样本
- 回顾性队列研究,来自7个参与机构的231例患者(胚胎性肿瘤50例、高级别胶质瘤127例、室管膜瘤54例);从T2加权和钆增强T1加权图像提取900个基于图像生物标志物标准化倡议的PyRadiomics特征,经稀疏回归分析降维后输入6种候选分类器模型,训练集与测试集按75:25随机分配。
关键影像表现/征象
- 肿瘤体积的T2加权和钆增强T1加权图像上提取的影像组学特征用于分类。
诊断标准与关键数值
- 胚胎性肿瘤 vs 高级别胶质瘤分类器:23个特征,AUC 0.98,敏感度0.85、特异度0.91、阳性预测值0.79、阴性预测值0.94、准确率0.89。
- 胚胎性肿瘤 vs 室管膜瘤分类器:4个特征,AUC 0.82,敏感度0.93、特异度0.69、阳性预测值0.76、阴性预测值0.90、准确率0.81。
- 高级别胶质瘤 vs 室管膜瘤分类器:35个特征,AUC 0.96,敏感度0.82、特异度0.94、阳性预测值0.82、阴性预测值0.94、准确率0.91。
临床应用与阅片要点
- 作者认为将该技术纳入诊断算法可改善诊断、风险分层和治疗计划。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Pediatric supratentorial tumors such as embryonal tumors, high-grade gliomas, and ependymomas are difficult to distinguish by histopathology and imaging because of overlapping features. We applied machine learning to uncover MR imaging-based radiomics phenotypes that can differentiate these tumor types.
MATERIALS AND METHODS: Our retrospective cohort of 231 patients from 7 participating institutions had 50 embryonal tumors, 127 high-grade gliomas, and 54 ependymomas. For each tumor volume, we extracted 900 Image Biomarker Standardization Initiative-based PyRadiomics features from T2-weighted and gadolinium-enhanced T1-weighted images. A reduced feature set was obtained by sparse regression analysis and was used as input for 6 candidate classifier models. Training and test sets were randomly allocated from the total cohort in a 75:25 ratio.
RESULTS: The final classifier model for embryonal tumor-versus-high-grade gliomas identified 23 features with an area under the curve of 0.98; the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 0.85, 0.91, 0.79, 0.94, and 0.89, respectively. The classifier for embryonal tumor-versus-ependymomas identified 4 features with an area under the curve of 0.82; the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 0.93, 0.69, 0.76, 0.90, and 0.81, respectively. The classifier for high-grade gliomas-versus-ependymomas identified 35 features with an area under the curve of 0.96; the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 0.82, 0.94, 0.82, 0.94, and 0.91, respectively.
CONCLUSIONS: In this multi-institutional study, we identified distinct radiomic phenotypes that distinguish pediatric supratentorial tumors, high-grade gliomas, and ependymomas with high accuracy. Incorporation of this technique in diagnostic algorithms can improve diagnosis, risk stratification, and treatment planning.
引用
- Zhang, Tam, Wright, et al. Radiomics Can Distinguish Pediatric Supratentorial Embryonal Tumors, High-Grade Gliomas, and Ependymomas. AJNR Am J Neuroradiol. 2022. PMID: 35361575. doi:10.3174/ajnr.A7481
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。