三维超短回波时间锥形绝热T1ρ成像对关节软骨退变的定量评估
研究纳入66名受试者,按Kellgren-Lawrence分级分为正常对照(KL0)、可疑-轻度骨关节炎(KL1-2)和中重度骨关节炎(KL3-4)三组,采用3D UTE-Cones-AdiabT1ρ序列定量评估膝关节软骨退变,并与KL分级和WORMS评分进行相关性分析。结果显示UTE-Cones-AdiabT1ρ值与KL分级(r=0.15)和WORMS(r=0.57)呈显著正相关,轻度软骨退变(WORMS=1)的诊断阈值为39.4 ms,敏感度80.8%,AUC为0.8。
要点
- 3D UTE-Cones-AdiabT1ρ序列可区分轻度软骨退变与正常软骨,诊断阈值39.4 ms,敏感度80.8%,AUC为0.8。
- UTE-Cones-AdiabT1ρ值与KL分级(r=0.15)和WORMS(r=0.57)呈显著正相关(p<0.05)。
- 软骨病灶范围越大、深度越深,UTE-Cones-AdiabT1ρ值越高,各范围组和深度组间差异均有统计学意义(p<0.05)。
核心结论
- 3D UTE-Cones-AdiabT1ρ序列可用于定量评估关节软骨退变,是早期软骨退变定量评估的有前景的生物标志物。
研究设计与样本
- 研究纳入66名人类受试者,由两名肌骨放射科医师评估Kellgren-Lawrence分级和WORMS评分,将受试者分为正常对照(KL0)、可疑-轻度骨关节炎(KL1-2)和中重度骨关节炎(KL3-4)三组;采用3D UTE-Cones数据采集,前置七个配对绝热全 passage 脉冲,对应七个自旋锁定时间(TSL)0、12、24、36、48、72和96 ms;通过ANOVA亚区分析、Spearman相关系数和ROC曲线评估技术性能。
关键影像表现/征象
- UTE-Cones-AdiabT1ρ值与KL分级呈显著正相关(r=0.15,p<0.05)。
- UTE-Cones-AdiabT1ρ值与WORMS呈显著正相关(r=0.57,p<0.05)。
- 软骨病灶范围较大和深度较深者,UTE-Cones-AdiabT1ρ值均较高,不同范围和深度组间差异均有统计学意义(p<0.05)。
- 亚区分析显示UTE-Cones-AdiabT1ρ与WORMS的相关性随软骨位置不同而变化。
诊断标准与关键数值
- 轻度软骨退变(WORMS=1)的UTE-Cones-AdiabT1ρ诊断阈值为39.4 ms,敏感度80.8%,AUC为0.8。
临床应用与阅片要点
- 3D UTE-Cones-AdiabT1ρ序列可用于定量评估关节软骨退变,有助于区分轻度软骨退变与正常软骨。
- UTE-Cones-AdiabT1ρ值与软骨病灶范围和深度相关,阅片时可结合病灶范围和深度综合评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate articular cartilage degeneration using quantitative three-dimensional ultrashort-echo-time cones adiabatic-T1ρ (3D UTE-Cones-AdiabT1ρ) imaging.
METHODS: Sixty-six human subjects were recruited for this study. Kellgren-Lawrence (KL) grade and Whole-Organ Magnetic-Resonance-Imaging Score (WORMS) were evaluated by two musculoskeletal radiologists. The human subjects were categorized into three groups, namely normal controls (KL0), doubtful-minimal osteoarthritis (OA) (KL1-2), and moderate-severe OA (KL3-4). WORMS were regrouped to encompass the extent of lesions and the depth of lesions. The UTE-Cones-AdiabT1ρ values were obtained using 3D UTE-Cones data acquisitions preceded by seven paired adiabatic full passage pulses that corresponded to seven spin-locking times (TSLs) of 0, 12, 24, 36, 48, 72, and 96 ms. The performance of the UTE-Cones-AdiabT1ρ technique in evaluating the degeneration of knee cartilage was assessed via the ANOVA comparisons with subregional analysis and Spearman's correlation coefficient as well as the receiver-operating-characteristic (ROC) curve.
RESULTS: UTE-Cones-AdiabT1ρ showed significant positive correlations with KL grade (r = 0.15, p < 0.05) and WORMS (r = 0.57, p < 0.05). Higher UTE-Cones-AdiabT1ρ values were observed in both larger and deeper lesions in the cartilage. The differences in UTE-Cones-AdiabT1ρ values among different extent and depth groups of cartilage lesions were all statistically significant (p < 0.05). Subregional analyses showed that the correlations between UTE-Cones-AdiabT1ρ and WORMS varied with the location of cartilage. The AUC value of UTE-Cones-AdiabT1ρ for mild cartilage degeneration (WORMS=1) was 0.8. The diagnostic threshold value of UTE-Cones-AdiabT1ρ for mild cartilage degeneration was 39.4 ms with 80.8% sensitivity.
CONCLUSIONS: The 3D UTE-Cones-AdiabT1ρ sequence can be useful in quantitative evaluation of articular cartilage degeneration.
KEY POINTS: • The 3D UTE-Cones-AdiabT1ρ sequence can distinguish mild cartilage degeneration from normal cartilage with a diagnostic threshold value of 39.4 ms for mild cartilage degeneration with 80.8% sensitivity. • Higher UTE-Cones-AdiabT1ρ values were observed in both larger and deeper lesions in the articular cartilage. • UTE-Cones-AdiabT1ρ is a promising biomarker for quantitative evaluation of early cartilage degeneration.
引用
- Wu, Ma, Liu, et al. Quantitative assessment of articular cartilage degeneration using 3D ultrashort echo time cones adiabatic T1ρ (3D UTE-Cones-AdiabT1ρ) imaging. Eur Radiol. 2022. PMID: 35357540. doi:10.1007/s00330-022-08722-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。