文献速递头颈甲状腺与浅表US

超声造影在原发性甲状旁腺功能亢进症中对甲状旁腺病灶定位的诊断价值:与彩色多普勒超声的比较

The Diagnostic Value of Contrast Enhanced Ultrasound for Localization of Parathyroid Lesions in Primary Hyperparathyroidism: Comparison With Color Doppler Ultrasound: Comparison With Color Doppler Ultrasound.
PubMed 文献 · J Ultrasound Med · 2022-03-31

该回顾性研究纳入142例接受甲状旁腺切除术的患者,比较超声造影(CEUS)与彩色多普勒超声(CDUS)对甲状旁腺病灶的定位价值。CEUS总体敏感度为77.6%,CDUS为74.6%,差异无统计学意义(P=0.516);在合并甲状腺疾病患者中CDUS敏感度高于CEUS,但差异无统计学意义(P=0.529);多发腺瘤检出敏感度两者相同。结论认为CEUS并未显示出显著优越的敏感度。

要点

  • CEUS对甲状旁腺病灶总体敏感度77.6%,CDUS为74.6%,两者差异无统计学意义(P=0.516)。
  • 合并甲状腺疾病患者中CDUS敏感度高于CEUS,但差异无统计学意义(P=0.529)。
  • 多发腺瘤检出敏感度CEUS与CDUS相同。

核心结论

  • CEUS在合并甲状腺疾病和多腺体病变情况下也未显示出显著优于CDUS的敏感度。

研究设计与样本

  • 回顾性研究,纳入142例接受甲状旁腺切除术的患者,比较术前影像与术中/组织病理学结果。

诊断标准与关键数值

  • CEUS定位甲状旁腺病灶的总体敏感度为77.6%。
  • CDUS定位甲状旁腺病灶的总体敏感度为74.6%,CEUS与CDUS比较P=0.516。
  • 合并甲状腺疾病患者中CDUS敏感度高于CEUS,但差异无统计学意义(P=0.529)。
  • 多发腺瘤检出敏感度CEUS与CDUS相同。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Preoperative localization of pathological parathyroid glands with imaging is essential for focused unilateral neck exploration and minimally invasive techniques. Recently published studies suggested that contrast-enhanced ultrasonography (CEUS) had high accuracy in the localization of hyperfunctioning parathyroid glands, with a general increase in the sensitivity as compared to conventional sonography. The purpose of this study was to determine the usefulness of CEUS in the localization of parathyroid lesions relating to surgical and histopathological data, in comparison to color Doppler ultrasound (CDUS), in the same series of patients.

METHODS: Records of 142 patients who underwent parathyroidectomy were retrospectively examined comparing imaging and intraoperative/histopathologic findings.

RESULTS: The overall sensitivity of CEUS was 77.6% compared with 74.6% for CDUS, although no significative differences were found (P = .516). Conversely, CDUS has shown higher sensitivity than CEUS in the group of patients with associated thyroid pathology but there was no statistical difference (P = .529). The sensitivity for detection of multiple adenomas was the same for both procedures.

CONCLUSIONS: We found no significative superior sensitivity of CEUS also in case of concomitant thyroid pathology and multiple glands disease.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Piccin, D'Alessio, Serra, et al. The Diagnostic Value of Contrast Enhanced Ultrasound for Localization of Parathyroid Lesions in Primary Hyperparathyroidism: Comparison With Color Doppler Ultrasound: Comparison With Color Doppler Ultrasound. J Ultrasound Med. 2022. PMID: 35357028. doi:10.1002/jum.15984

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。