弥散加权成像能否为Kaiser评分在乳腺病变评估中提供附加价值
本研究回顾性纳入2015年1月至2019年12月246例患者的273个乳腺病变(155个恶性),评估DWI作为Kaiser评分辅助手段的附加价值。Kaiser评分诊断效能高于单独DWI(AUC 0.941 vs 0.901,p=0.04),DWI联合Kaiser评分仅使特异度提高0-2.5%、敏感度降低0.1-1.3%,差异无统计学意义(p>0.05)。结论认为DWI对Kaiser评分无附加价值。
要点
- Kaiser评分诊断乳腺良恶性病变的AUC为0.941,显著高于单独DWI的0.901(p=0.04)。
- 单独DWI敏感度高(97.4-99.4%)但特异度低(19.5-56.8%),Kaiser评分特异度83.9%显著更高。
- DWI联合Kaiser评分未显著改善诊断效能,特异度仅提高0-2.5%、敏感度降低0.1-1.3%(p>0.05)。
核心结论
- Kaiser评分对乳腺良恶性病变的鉴别诊断效能高于单独DWI,DWI对Kaiser评分无附加价值。
研究设计与样本
- 回顾性研究,纳入2015年1月至2019年12月246例患者的273个乳腺病变(155个恶性),所有病变经病理证实,由两名对病理结果不知情的放射科医师按Kaiser评分评估,评分>4分视为恶性。
诊断标准与关键数值
- Kaiser评分>4分视为恶性;采用1.3×10-3mm2/s、1.4×10-3mm2/s、1.53×10-3mm2/s和1.6×10-3mm2/s四个ADC阈值鉴别良恶性;联合诊断以Kaiser评分>4分且ADC低于预设界值视为恶性;Kaiser评分AUC 0.941、敏感度96.8%、特异度83.9%;DWI敏感度97.4-99.4%、特异度19.5-56.8%、AUC 0.901。
临床应用与阅片要点
- 阅片时可依据Kaiser评分对乳腺MRI病变进行良恶性评估,原文结论认为DWI作为Kaiser评分的辅助手段未显示附加价值。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To explore added value of diffusion-weighted imaging (DWI) as an adjunct to Kaiser score (KS) for differentiation of benign from malignant lesions on breast magnetic resonance imaging (MRI).
METHODS: Two hundred forty-six patients with 273 lesions (155 malignancies) were included in this retrospective study from January 2015 to December 2019. All lesions were proved by pathology. Two radiologists blind to pathological results evaluated lesions according to KS. Lesions with score > 4 were considered malignant. Four thresholds of ADC values -1.3 × 10-3mm2/s, 1.4 × 10-3mm2/s, 1.53 × 10-3mm2/s, and 1.6 × 10-3mm2/s were used to distinguish benign from malignant lesions. For combined diagnosis, a lesion with KS > 4 and ADC values below the preset cutoffs was considered as malignant; otherwise, it was benign. Sensitivity, specificity, and area under the curve (AUC) were compared between KS, DWI, and combined diagnosis.
RESULTS: The AUC of KS was significantly higher than that of DWI alone (0.941 vs 0.901, p = 0.04). The sensitivity of KS (96.8%) and DWI (97.4 - 99.4%) was comparable (p > 0.05) while the specificity of KS (83.9%) was significantly higher than that of DWI (19.5-56.8%) (p < 0.05). Adding DWI as an adjunct to KS resulted in a 0-2.5% increase of specificity and a 0.1-1.3% decrease of sensitivity; however, the difference did not reach statistical significance (p > 0.05).
CONCLUSION: KS showed higher diagnostic performance than DWI alone for discrimination of breast benign and malignant lesions. DWI showed no additional value to KS for characterizing breast lesions.
KEY POINTS: • KS showed higher diagnostic performance than DWI alone for differentiation of benign from breast malignant lesions. • DWI alone showed a high sensitivity but a low specificity for characterizing breast lesions. • Diagnostic performance did not improve using DWI as an adjunct to KS.
引用
- An, Mao, Ao, et al. Can DWI provide additional value to Kaiser score in evaluation of breast lesions. Eur Radiol. 2022. PMID: 35357535. doi:10.1007/s00330-022-08674-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。