文献速递胸部CT

临床光子计数探测器CT生成的虚拟平扫图像用于肺气肿定量的性能:概念验证

Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept.
PubMed 文献 · Br J Radiol · 2022-04-19

回顾性纳入65例在双源光子计数探测器CT上接受三期(平扫、动脉期、静脉期)胸腹部CT的患者,比较虚拟平扫(VNC)与真实平扫(TNC)对肺实质及肺气肿定量的评估性能;VNCart与VNCven在肺气肿定量上与TNC无显著差异,主观图像质量以TNC最高。

要点

  • 光子计数探测器CT的虚拟平扫图像(VNCart和VNCven)与真实平扫的肺气肿定量无显著差异。
  • 主观图像质量(肺气肿评估和整体图像质量)以真实平扫最高,其次为VNCven、VNCart。
  • 基于上述发现,未来或可省略用于肺气肿定量的额外真实平扫扫描。

核心结论

  • 使用光子计数探测器CT的虚拟平扫图像评估肺气肿是可行的,VNC图像用于肺气肿定量可行且准确。

研究设计与样本

  • 回顾性纳入65例(平均年龄73岁;48例男性)连续患者,均接受第一代双源光子计数探测器CT三期(平扫、动脉期和静脉期)胸腹部CT,采用多能量(QuantumPlus)模式、120 kV、静脉注射对比剂70 ml、注射速率4 ml/s,从动脉期和静脉期重建VNC(分别为VNCart和VNCven),以真实平扫作为肺气肿定量的参考标准。

诊断标准与关键数值

  • 肺气肿定量使用商用软件工具,所有数据集均以-950 HU为阈值;低衰减值(LAV)采用Bland-Altman图比较;全局噪声指数(GNI)VNCart为103.0 ± 30.1、VNCven为98.2 ± 22.2、TNC为100.9 ± 19.0(VNCart与TNC比较p = 0.546,VNCven与TNC比较p = 0.272);肺气肿定量VNCart与TNC比较p = 0.409、VNCven与TNC比较p = 0.093;主观图像质量(肺气肿评估和整体图像质量)以TNC最高(p = 0.001),其次为VNCven和VNCart。

临床应用与阅片要点

  • 作者认为,基于这些发现,未来或可省略用于肺气肿定量的额外真实平扫扫描。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the performance of virtual non-contrast images (VNC) compared to true non-contrast (TNC) images in photon-counting detector computed tomography (PCD-CT) for the evaluation of lung parenchyma and emphysema quantification.

METHODS: 65 (mean age 73 years; 48 male) consecutive patients who underwent a three-phase (non-contrast, arterial and venous) chest/abdomen CT on a first-generation dual-source PCD-CT were retrospectively included. Scans were performed in the multienergy (QuantumPlus) mode at 120 kV with 70 ml intravenous contrast agent at an injection rate of 4 ml s-1. VNC were reconstructed from the arterial (VNCart) and venous phase (VNCven). TNC and VNC images of the lung were assessed quantitatively by calculating the global noise index (GNI) and qualitatively by two independent, blinded readers (overall image quality and emphysema assessment). Emphysema quantification was performed using a commercially available software tool at a threshold of -950 HU for all data sets. TNC images served as reference standard for emphysema quantification. Low attenuation values (LAV) were compared in a Bland-Altman plot.

RESULTS: GNI was similar in VNCart (103.0 ± 30.1) and VNCven (98.2 ± 22.2) as compared to TNC (100.9 ± 19.0, p = 0.546 and p = 0.272, respectively). Subjective image quality (emphysema assessment and overall image quality) was highest for TNC (p = 0.001), followed by VNCven and VNCart. Both, VNCart and VNCven showed no significant difference in emphysema quantification as compared to TNC (p = 0.409 vs. p = 0.093; respectively).

CONCLUSION: Emphysema evaluation is feasible using virtual non-contrast images from PCD-CT.

ADVANCES IN KNOWLEDGE: Emphysema quantification is feasible and accurate using VNC images in PCD-CT. Based on these findings, additional TNC scans for emphysema quantification could be omitted in the future.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Jungblut, Sartoretti, Kronenberg, et al. Performance of virtual non-contrast images generated on clinical photon-counting detector CT for emphysema quantification: proof of concept. Br J Radiol. 2022. PMID: 35357902. doi:10.1259/bjr.20211367

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。