文献速递心血管胸部CT

基于机器学习的影像组学通过心外膜脂肪在增强与非增强胸部CT上识别心房颤动

Machine-learning-based radiomics identifies atrial fibrillation on the epicardial fat in contrast-enhanced and non-enhanced chest CT.
PubMed 文献 · Br J Radiol · 2022-04-19

研究回顾性分析基于心电图诊断的心房颤动患者,分别接受增强胸部CT(n=200)或非增强胸部CT(n=300),对心外膜脂肪进行分割并提取1691个影像组学特征,用Boruta算法和随机森林算法构建EAT-score。在增强CT测试集(n=60/200)中EAT-score识别心房颤动的AUC为0.92(95%CI: 0.84-1.00),高于临床因素模型的0.71(0.58-0.85)和心外膜脂肪体积模型的0.73(0.61-0.86);在非增强CT测试集(n=100/300)中AUC为0.85(0.77-0.92),高于CT衰减模型(P<0.001)。

要点

  • 增强胸部CT测试集中EAT-score识别心房颤动的AUC为0.92(95%CI: 0.84-1.00)。
  • 非增强胸部CT测试集中EAT-score识别心房颤动的AUC为0.85(95%CI: 0.77-0.92)。
  • 增强CT中EAT-score的AUC高于临床因素模型和心外膜脂肪体积模型(DeLong P=0.01)。

核心结论

  • 基于机器学习的影像组学生成的EAT-score在识别心房颤动患者方面取得高性能。

研究设计与样本

  • 回顾性分析基于心电图诊断的心房颤动患者,接受增强胸部CT者200例、非增强胸部CT者300例;对心外膜脂肪分割后提取1691个影像组学特征,用Boruta算法和基于机器学习的随机森林算法筛选特征并构建EAT-score;采用多因素逻辑回归构建临床因素模型和嵌套模型。

诊断标准与关键数值

  • 增强胸部CT测试集(n=60/200)中EAT-score识别心房颤动的AUC为0.92(95%CI: 0.84-1.00)。
  • 增强胸部CT测试集中临床因素模型(总胆固醇和体重指数)的AUC为0.71(95%CI: 0.58-0.85),EAT-score高于该模型(DeLong P=0.01)。
  • 增强胸部CT测试中心外膜脂肪体积模型的AUC为0.73(95%CI: 0.61-0.86),EAT-score高于该模型(P=0.01)。
  • 非增强胸部CT测试集(n=100/300)中EAT-score识别心房颤动的AUC为0.85(95%CI: 0.77-0.92),高于CT衰减模型(P<0.001)。
  • 增强胸部CT的两个嵌套模型(EAT-score+体积、EAT-score+体积+临床因素)及非增强胸部CT的一个嵌套模型(EAT-score+CT衰减)的AUC与EAT-score相似(所有P>0.05)。

临床应用与阅片要点

  • 作者认为,基于机器学习的影像组学分析可在增强和非增强胸部CT的心外膜脂肪上识别心房颤动。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose is to establish and validate a machine-learning-derived radiomics approach to determine the existence of atrial fibrillation (AF) by analyzing epicardial adipose tissue (EAT) in CT images.

METHODS: Patients with AF based on electrocardiographic tracing who underwent contrast-enhanced (n = 200) or non-enhanced (n = 300) chest CT scans were analyzed retrospectively. After EAT segmentation and radiomics feature extraction, the segmented EAT yielded 1691 radiomics features. The most contributive features to AF were selected by the Boruta algorithm and machine-learning-based random forest algorithm, and combined to construct a radiomics signature (EAT-score). Multivariate logistic regression was used to build clinical factor and nested models.

RESULTS: In the test cohort of contrast-enhanced scanning (n = 60/200), the AUC of EAT-score for identifying patients with AF was 0.92 (95%CI: 0.84-1.00), higher than 0.71 (0.58-0.85) of the clinical factor model (total cholesterol and body mass index) (DeLong's p = 0.01), and higher than 0.73 (0.61-0.86) of the EAT volume model (p = 0.01). In the test cohort of non-enhanced scanning (n = 100/300), the AUC of EAT-score was 0.85 (0.77-0.92), higher than that of the CT attenuation model (p < 0.001). The two nested models (EAT-score+volume and EAT-score+volume+clinical factors) for contrast-enhanced scan and one (EAT-score+CT attenuation) for non-enhanced scan showed similar AUCs with that of EAT-score (all p > 0.05).

CONCLUSION: EAT-score generated by machine-learning-based radiomics achieved high performance in identifying patients with AF.

ADVANCES IN KNOWLEDGE: A radiomics analysis based on machine learning allows for the identification of AF on the EAT in contrast-enhanced and non-enhanced chest CT.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang, Xu, Jiang, et al. Machine-learning-based radiomics identifies atrial fibrillation on the epicardial fat in contrast-enhanced and non-enhanced chest CT. Br J Radiol. 2022. PMID: 35357893. doi:10.1259/bjr.20211274

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。