文献速递骨肌MR

三维CAIPIRINHA SPACE与标准二维TSE用于常规膝关节MRI:一项大规模可互换性研究

3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study.
PubMed 文献 · Eur Radiol · 2022-03-30

本前瞻性研究纳入250例患者行3T膝关节MRI,比较多对比三维CAIPIRINHA SPACE TSE(9:26分钟)与标准二维TSE(12:14分钟)的可互换性。除髌骨和滑车软骨缺损外,两种方案对膝关节异常的诊断可互换;放射科医师对二维TSE的图像质量和诊断信心更高。

要点

  • 除髌股关节软骨缺损外,三维CAIPIRINHA SPACE与二维TSE诊断膝关节异常可互换。
  • 医师对二维TSE的图像质量和诊断信心高于三维CAIPIRINHA SPACE TSE。
  • 三维CAIPIRINHA SPACE TSE扫描时间9:26分钟,短于二维TSE的12:14分钟。

核心结论

  • 多对比三维CAIPIRINHA SPACE TSE与标准二维TSE方案在诊断膝关节异常方面表现可互换,但髌股关节软骨缺损除外;尽管放射科医师偏好二维TSE,追求节省时间的三维TSE膝关节MRI用于常规实践是合理的。

研究设计与样本

  • 前瞻性研究,纳入250例患者行3T膝关节MRI,包括多对比三维CAIPIRINHA SPACE TSE(9:26分钟)和标准二维TSE方案(12:14分钟)。

诊断标准与关键数值

  • 两位放射科医师采用4分Likert量表根据诊断信心水平评估图像质量并识别半月板、韧带和软骨病变;在同一阅片者情景下使用bootstrap百分位置信区间检验方案可互换性。

临床应用与阅片要点

  • 作者认为,尽管放射科医师偏好二维TSE,追求加速三维TSE膝关节MRI用于常规实践是合理的。

局限性

  • 髌骨软骨缺损差异6.8%(95%CI:4.0,9.6)和滑车软骨缺损差异3.6%(95%CI:0.8,6.6)超出可互换范围,髌股关节软骨缺损除外。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To perform a large-scale interchangeability study comparing 3D controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) sampling perfection with application optimized contrast using different flip angle evolutions (SPACE) TSE with standard 2D TSE for knee MRI.

METHODS: In this prospective study, 250 patients underwent 3 T knee MRI, including a multicontrast 3D CAIPIRINHA SPACE TSE (9:26 min) and a standard 2D TSE protocol (12:14 min). Thirty-three (13%) patients had previous anterior cruciate ligament and/or meniscus surgery. Two radiologists assessed MRIs for image quality and identified pathologies of menisci, ligaments, and cartilage by using a 4-point Likert scale according to the level of diagnostic confidence. Interchangeability of the protocols was tested under the same-reader scenario using a bootstrap percentile confidence interval. Interreader reliability and intermethod concordance were also evaluated.

RESULTS: Despite higher image quality and diagnostic confidence for standard 2D TSE compared to 3D CAIPIRINHA SPACE TSE, the protocols were found interchangeable for diagnosing knee abnormalities, except for patellar (6.8% difference; 95% CI: 4.0, 9.6) and trochlear (3.6% difference; 95% CI: 0.8, 6.6) cartilage defects. The interreader reliability was substantial to almost perfect for 2D and 3D MRI (range κ, 0.785-1 and κ, 0.725-0.964, respectively). Intermethod concordance was almost perfect for all diagnoses (range κ, 0.817-0.986).

CONCLUSION: Multicontrast 3D CAIPIRINHA SPACE TSE and standard 2D TSE protocols perform interchangeably for diagnosing knee abnormalities, except for patellofemoral cartilage defects. Despite the radiologist's preference for 2D TSE imaging, a pursuit towards time-saving 3D TSE knee MRI is justified for routine practice.

KEY POINTS: • Multicontrast 3D CAIPIRINHA SPACE and standard 2D TSE protocols perform interchangeably for diagnosing knee abnormalities, except for patellofemoral cartilage defects. • Radiologists are more confident in diagnosing knee abnormalities on 2D TSE than on 3D CAIPIRINHA SPACE TSE MRI. • Despite the radiologist's preference for 2D TSE, a pursuit towards accelerated 3D TSE knee MRI is justified for routine practice.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Van Dyck, Smekens, Roelant, et al. 3D CAIPIRINHA SPACE versus standard 2D TSE for routine knee MRI: a large-scale interchangeability study. Eur Radiol. 2022. PMID: 35353196. doi:10.1007/s00330-022-08715-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。