文献速递神经CT

脑内血肿扩大的非增强CT标志物:一项信度研究

Non-contrast CT markers of intracerebral hematoma expansion: a reliability study.
PubMed 文献 · Eur Radiol · 2022-03-29

本研究从本地数据集中随机抽取60例自发性脑内出血患者,由15名不同背景和培训水平的医生及学员依据标准化定义识别6种密度标志物和3种形状标志物,其中13名评估者进行第二次评估。结果显示仅4/9个非增强CT血肿扩大标志物的评估者间信度达到高度至几乎完全一致(Gwet's AC1>0.60),其中漩涡征和液平征信度最高。

要点

  • 漩涡征(AC1=0.85)和液平征(AC1=0.84)的评估者间信度几乎完全一致。
  • 低密度征(AC1=0.67)和混合征(AC1=0.62)的评估者间信度高度一致。
  • 需识别特定轴位层面的三个标志物(Barras密度、Barras形状、岛征)评估者间信度较低(AC1=0.46)。

核心结论

  • 在15名评估者和60例患者中,9个非增强CT血肿扩大标志物中仅4个(漩涡征、液平征、低密度征、混合征)的评估者间信度达到高度至几乎完全一致(Gwet's AC1>0.60)。

研究设计与样本

  • 信度研究,从本地数据集中随机抽取60例自发性脑内出血患者,由15名卒中神经内科、介入神经放射科和诊断神经放射科的医生及学员在培训后依据标准化定义识别9个非增强CT血肿扩大标志物,其中13名评估者进行第二次评估,采用Gwet's AC1测量评估者间和评估者内信度。

关键影像表现/征象

  • 漩涡征评估者间AC1为0.85(95%CI:0.78-0.90),几乎完全一致。
  • 液平征评估者间AC1为0.84(95%CI:0.76-0.90),几乎完全一致。
  • 低密度征评估者间AC1为0.67(95%CI:0.56-0.76),高度一致。
  • 混合征评估者间AC1为0.62(95%CI:0.51-0.71),高度一致。
  • 其余标志物评估者间信度为中等,密度标志物与形状标志物之间信度相当。

诊断标准与关键数值

  • Gwet's AC1系数>0.60定义为高度至几乎完全一致。
  • 漩涡征评估者间AC1为0.85(95%CI:0.78-0.90),液平征为0.84(95%CI:0.76-0.90)。
  • 低密度征评估者间AC1为0.67(95%CI:0.56-0.76),混合征为0.62(95%CI:0.51-0.71)。
  • 需识别特定轴位层面的三个标志物(Barras密度、Barras形状、岛征)评估者间AC1为0.46(95%CI:0.40-0.52),其他标志物为0.60(95%CI:0.56-0.63)。
  • 除黑洞征外,其余8个标志物的评估者内信度均为高度至几乎完全一致。

临床应用与阅片要点

  • 漩涡征、液平征、低密度征和混合征的评估者间信度较高,适合用于日常阅片和报告。
  • 需识别特定轴位层面的标志物(Barras密度、Barras形状、岛征)评估者间信度较低,阅片时需注意其可重复性有限。
  • 评估者间信度不受评估者经验、血肿位置、血肿体积或抗凝状态影响。
  • 仅混合征、液平征和漩涡征在评估者间信度、评估者内信度和与参考阅片结果的一致性三项信度指标上均达到高度至几乎完全一致。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We evaluated whether clinicians agree in the detection of non-contrast CT markers of intracerebral hemorrhage (ICH) expansion.

METHODS: From our local dataset, we randomly sampled 60 patients diagnosed with spontaneous ICH. Fifteen physicians and trainees (Stroke Neurology, Interventional and Diagnostic Neuroradiology) were trained to identify six density (Barras density, black hole, blend, hypodensity, fluid level, swirl) and three shape (Barras shape, island, satellite) expansion markers, using standardized definitions. Thirteen raters performed a second assessment. Inter- and intra-rater agreement were measured using Gwet's AC1, with a coefficient > 0.60 indicating substantial to almost perfect agreement.

RESULTS: Almost perfect inter-rater agreement was observed for the swirl (0.85, 95% CI: 0.78-0.90) and fluid level (0.84, 95% CI: 0.76-0.90) markers, while the hypodensity (0.67, 95% CI: 0.56-0.76) and blend (0.62, 95% CI: 0.51-0.71) markers showed substantial agreement. Inter-rater agreement was otherwise moderate, and comparable between density and shape markers. Inter-rater agreement was lower for the three markers that require the rater to identify one specific axial slice (Barras density, Barras shape, island: 0.46, 95% CI: 0.40-0.52 versus others: 0.60, 95% CI: 0.56-0.63). Inter-observer agreement did not differ when stratified for raters' experience, hematoma location, volume, or anticoagulation status. Intra-rater agreement was substantial to almost perfect for all but the black hole marker.

CONCLUSION: In a large sample of raters with different backgrounds and expertise levels, only four of nine non-contrast CT markers of ICH expansion showed substantial to almost perfect inter-rater agreement.

KEY POINTS: • In a sample of 15 raters and 60 patients, only four of nine non-contrast CT markers of ICH expansion showed substantial to almost perfect inter-rater agreement (Gwet's AC1> 0.60). • Intra-rater agreement was substantial to almost perfect for eight of nine hematoma expansion markers. • Only the blend, fluid level, and swirl markers achieved substantial to almost perfect agreement across all three measures of reliability (inter-rater agreement, intra-rater agreement, agreement with the results of a reference reading).

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Nehme, Ducroux, Panzini, et al. Non-contrast CT markers of intracerebral hematoma expansion: a reliability study. Eur Radiol. 2022. PMID: 35348859. doi:10.1007/s00330-022-08710-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。