文献速递神经头颈MR

经神经导航单阵元脉冲聚焦超声对上位颅神经进行超声辐照的人体应用可行性

Feasibility of Upper Cranial Nerve Sonication in Human Application via Neuronavigated Single-Element Pulsed Focused Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2022-03-25

研究采用人颅骨标本进行计算与实验测试,评估在蝶骨区域附近对三叉神经通路进行超声辐照的可行性。结果显示焦距120 mm、直径85 mm(350 kHz)的换能器可达到与既往人体研究聚焦超声脑靶点相当的空间精度,骨内温度测量显示骨加热轻微,常规脉冲参数会在颅底附近产生混响干扰,调整脉冲周期和脉冲重复频率可减少驻波。

要点

  • 焦距120 mm、直径85 mm(350 kHz)换能器可对上部颅神经区域辐照,空间精度与既往人体聚焦超声脑靶点相当。
  • cortical bone和颅底埋置热电偶测温显示骨加热轻微。
  • 常规脉冲参数在颅底附近产生混响干扰,调整脉冲周期和脉冲重复频率可减少驻波。

核心结论

  • 使用焦距120 mm、直径85 mm(350 kHz)的换能器可对上位颅神经区域进行超声辐照,空间精度与既往人体研究聚焦超声脑靶点相当,骨加热轻微,但常规脉冲参数会在颅底附近产生混响干扰,需调整脉冲周期和脉冲重复频率以减少驻波。

研究设计与样本

  • 采用人颅骨标本进行一系列计算与实验测试,评估在蝶骨区域附近对三叉神经通路进行超声辐照的可行性;使用磁共振成像引导神经导航单阵元压电换能器。

局限性

  • 原文讨论了对人体应用中进行超深部聚焦靶向的局限性与考虑因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Sonicating deep brain regions with pulsed focused ultrasound using magnetic resonance imaging-guided neuronavigation single-element piezoelectric transducers is a new area of exploration for neuromodulation. Upper cranial nerves such as the trigeminal nerve and other nerves responsible for sensory/motor functions in the head may be potential targets for ultrasound pain therapy. The location of upper cranial nerves close to the skull base poses additional challenges when compared with conventional cortical or middle brain targets. In the work described here, a series of computational and empirical testing methods using human skull specimens were conducted to assess the feasibility of sonicating the trigeminal pathway near the sphenoid bone region. The results indicate a transducer with a focal length of 120 mm and diameter of 85 mm (350 kHz) can deliver sonication to upper cranial nerve regions with spatial accuracy comparable to that of focused ultrasound brain targets used in previous human studies. Temperature measurements in cortical bone and in the skull base with embedded thermocouples yield evidence of minimal bone heating. Conventional pulse parameters were found to cause reverberation interference patterns near the cranial floor; therefore, changes in pulse cycles and pulse repetition frequency were examined for reducing standing waves. Limitations and considerations for conducting ultradeep focal targeting in human applications are discussed.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Brinker, Balchandani, Seifert, et al. Feasibility of Upper Cranial Nerve Sonication in Human Application via Neuronavigated Single-Element Pulsed Focused Ultrasound. Ultrasound Med Biol. 2022. PMID: 35341621. doi:10.1016/j.ultrasmedbio.2022.01.022

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。