文献速递介入腹部外周血管CTDSA

基于锥形束CT的虚拟注射软件在肝动脉栓塞术中血管检测的准确性

Accuracy of a CBCT-based virtual injection software for vessel detection during hepatic arterial embolization.
PubMed 文献 · Eur J Radiol · 2022-03-21

回顾性纳入2019年3月至2020年5月20例在同一手术中完成非选择性注入CBCT和选择性CTA的患者,评估虚拟注射软件模拟选择性动脉注射的准确性。195个血管段中,1–3级动脉完美至良好占96.8%±1.4,4–5级动脉占83.4%±0.4,观察者间一致性Fleiss kappa=0.79(95%CI 0.73–0.84,P<0.01),平均敏感度90.6%±0.3、PPV 92.7%±0.02。结论认为该软件能准确模拟肝内远端注射。

要点

  • 虚拟注射对1–3级动脉模拟完美至良好占96.8%±1.4,4–5级动脉占83.4%±0.4。
  • 观察者间一致性Fleiss kappa=0.79(95%CI 0.73–0.84,P<0.01),为高度一致。
  • 平均敏感度90.6%±0.3,平均PPV 92.7%±0.02,假阴性平均9.4%±0.3。

核心结论

  • 基于CBCT的虚拟注射软件能以高敏感度和高度观察者间一致性准确模拟肝内远端注射。

研究设计与样本

  • 回顾性研究,2019年3月至2020年5月连续纳入20例在同一手术中完成非选择性注入CBCT和选择性CTA的患者。
  • 将选择性CTA注射用微导管尖端位置作为参照点,在非选择性CBCT相同点模拟虚拟注射并融合两组容积进行对比。
  • 由3名介入放射科医生采用6分制(完美、良好、一般、起源错误、假阴性、不存在)评估准确性。

关键影像表现/征象

  • 共分析20例操作和195个血管段,多数血管为4级(57/195;29%)和5级(96/195;49%)。
  • 虚拟注射评为完美至良好的比例在1–3级动脉为96.8%±1.4,在4–5级动脉为83.4%±0.4。

诊断标准与关键数值

  • 准确性采用6分制评估:完美、良好、一般、起源错误、假阴性、不存在。
  • 平均敏感度90.6%±0.3,平均PPV 92.7%±0.02。
  • 假阴性平均9.4%±0.3,另记录14个假阳性。
  • 观察者间一致性Fleiss kappa=0.79(95%CI 0.73–0.84,P<0.01)。

临床应用与阅片要点

  • 虚拟注射软件可基于非选择性CBCT模拟选择性注射,辅助术前评估肝内远端血管走行。
  • 需注意4–5级动脉完美至良好比例(83.4%±0.4)低于1–3级动脉(96.8%±1.4),并存在假阴性和假阳性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the accuracy, sensitivity, positive predictive value (PPV) and interobserver agreement of a virtual injection (VI) software that simulates selective arterial injection from nonselective cone-beam CT (CBCT) arteriography.

METHODS: From March 2019 to May 2020, 20 consecutive patients in whom a nonselective injected CBCT and a selective CT angiography (CTA) were completed in the same procedure, were retrospectively included. The position of the microcatheter tip used for selective CTA injection was identified. The VI was simulated from the exact same point on the nonselective CBCT and the two volumes were merged. VI was compared to the real injection on the selective CTA. Three interventional radiologists evaluated the accuracy using a 6-point scale (Perfect; Good; Fair; Incorrect Origin; False Negative; Non existing). Sensitivity, PPV, and Fleiss' kappa were calculated. Numerical variables were presented as means ± standard deviations.

RESULTS: Twenty procedures and 195 vessel segments were analyzed. Most vessels were 4th order (57/195; 29%) and 5th order (96/195; 49%). VI was classified as perfect to good in 96.8% ± 1.4 of 1st-3rd order arteries and in 83.4% ± 0.4 of 4th-5th order arteries. Interobserver agreement was substantial (Fleiss' kappa = 0.79; 95% confidence interval = 0.73-0.84, P < 0.01). False negatives were reported with a mean of 9.4% ± 0.3. Average sensitivity was 90.6% ± 0.3 and average PPV was 92.7% ± 0.02. Fourteen false positives were noted.

CONCLUSION: CBCT-based VI software accurately simulated distal injections in the liver with high sensitivity and a substantial interobserver agreement.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Ridouani, Ghosn, Doustaly, et al. Accuracy of a CBCT-based virtual injection software for vessel detection during hepatic arterial embolization. Eur J Radiol. 2022. PMID: 35338952. doi:10.1016/j.ejrad.2022.110273

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。