深度学习重建高分辨率3D腰椎MRI的评估
本研究回顾性纳入35例患者,比较深度学习重建(DLRecon)3D T2w-FSE与标准重建3D及2D T2w-FSE腰椎MRI的图像质量和观察者间一致性。DLRecon 3D图像质量评分显著更高(2.0/2 vs 1.0/2,p<0.001),各序列观察者间一致性相似。
要点
- DLRecon 3D T2w-FSE腰椎MRI图像质量评分中位数2.0/2,显著高于SOC 3D、2D轴位及2D矢状位(均1.0/2,p<0.001)。
- DLRecon 3D、SOC 3D及2D序列对椎间孔狭窄的观察者间一致性相似,κ范围分别为0.55-0.76、0.56-0.73、0.58-0.71。
- L4-5中央椎管狭窄的平均κ在DLRecon 3D、SOC 3D及2D分别为0.98、0.97、0.98,各序列一致性均很高。
核心结论
- DLRecon 3D T2w-FSE腰椎MRI较SOC 3D及2D成像图像质量更高,且目标分级变量的观察者间一致性相似。
研究设计与样本
- 经IRB批准,回顾性纳入2020年8月17日至9月17日接受常规3-T腰椎MRI且包含各向同性3D和2D T2w-FSE序列的患者,共35例(平均年龄58±19岁,26例女性);对SOC 3D k空间应用具有去噪和锐化特性的DLRecon算法生成3D DLRecon图像;由4名不知晓重建状态的肌骨放射科医生对随机图像进行评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare interobserver agreement and image quality of 3D T2-weighted fast spin echo (T2w-FSE) L-spine MRI images processed with a deep learning reconstruction (DLRecon) against standard-of-care (SOC) reconstruction, as well as against 2D T2w-FSE images. The hypothesis was that DLRecon 3D T2w-FSE would afford improved image quality and similar interobserver agreement compared to both SOC 3D and 2D T2w-FSE.
METHODS: Under IRB approval, patients who underwent routine 3-T lumbar spine (L-spine) MRI from August 17 to September 17, 2020, with both isotropic 3D and 2D T2w-FSE sequences, were retrospectively included. A DLRecon algorithm, with denoising and sharpening properties was applied to SOC 3D k-space to generate 3D DLRecon images. Four musculoskeletal radiologists blinded to reconstruction status evaluated randomized images for motion artifact, image quality, central/foraminal stenosis, disc degeneration, annular fissure, disc herniation, and presence of facet joint cysts. Inter-rater agreement for each graded variable was evaluated using Conger's kappa (κ).
RESULTS: Thirty-five patients (mean age 58 ± 19, 26 female) were evaluated. 3D DLRecon demonstrated statistically significant higher median image quality score (2.0/2) when compared to SOC 3D (1.0/2, p < 0.001), 2D axial (1.0/2, p < 0.001), and 2D sagittal sequences (1.0/2, p value < 0.001). κ ranges (and 95% CI) for foraminal stenosis were 0.55-0.76 (0.32-0.86) for 3D DLRecon, 0.56-0.73 (0.35-0.84) for SOC 3D, and 0.58-0.71 (0.33-0.84) for 2D. Mean κ (and 95% CI) for central stenosis at L4-5 were 0.98 (0.96-0.99), 0.97 (0.95-0.99), and 0.98 (0.96-0.99) for 3D DLRecon, 3D SOC and 2D, respectively.
CONCLUSIONS: DLRecon 3D T2w-FSE L-spine MRI demonstrated higher image quality and similar interobserver agreement for graded variables of interest when compared to 3D SOC and 2D imaging.
KEY POINTS: • 3D DLRecon T2w-FSE isotropic lumbar spine MRI provides improved image quality when compared to 2D MRI, with similar interobserver agreement for clinical evaluation of pathology. • 3D DLRecon images demonstrated better image quality score (2.0/2) when compared to standard-of-care (SOC) 3D (1.0/2), p value < 0.001; 2D axial (1.0/2), p value < 0.001; and 2D sagittal sequences (1.0/2), p value < 0.001. • Interobserver agreement for major variables of interest was similar among all sequences and reconstruction types. For foraminal stenosis, κ ranged from 0.55 to 0.76 (95% CI 0.32-0.86) for 3D DLRecon, 0.56-0.73 (95% CI 0.35-0.84) for standard-of-care (SOC) 3D, and 0.58-0.71 (95% CI 0.33-0.84) for 2D.
引用
- Sun, Tan, Mintz, et al. Evaluation of deep learning reconstructed high-resolution 3D lumbar spine MRI. Eur Radiol. 2022. PMID: 35322280. doi:10.1007/s00330-022-08708-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。