动脉内血管内取栓术前侧支循环评分预测卒中结局的诊断准确性:DSA与CTA的Meta分析
该诊断性Meta分析比较DSA与CTA的侧支循环评分系统预测动脉内血管内取栓术后90天良好功能结局的准确性:DSA汇总敏感度0.72、特异度0.61,CTA汇总敏感度0.74、特异度0.53;两者准确性相当,但预测功能结局的作用有限,更适合筛查而非诊断。
要点
- DSA侧支评分预测90天良好功能结局汇总敏感度0.72、特异度0.61,AUC 0.71。
- CTA侧支评分汇总敏感度0.74、特异度0.53,AUC 0.67。
- DSA与CTA准确性相当,预测功能结局作用有限,更适合筛查而非诊断。
核心结论
- DSA与CTA的侧支循环评分准确性相当,但两者预测动脉内血管内取栓术后90天良好功能结局的作用均有限。
- DSA与CTA评估的侧支循环评分系统更适合用于动脉内血管内取栓术前患者的筛查而非诊断。
研究设计与样本
- 诊断性Meta分析,分别评估DSA与CTA侧支循环评分系统的敏感度与特异度。
- 共纳入DSA研究14项、CTA研究21项,采用分层汇总受试者工作特征曲线(HSROC)模型估计诊断比值比(DOR)与曲线下面积(AUC)。
- 采用贝叶斯定理计算验后概率(PTP)。
诊断标准与关键数值
- DSA侧支评分:汇总敏感度0.72(95%CI 0.63-0.79),汇总特异度0.61(95%CI 0.53-0.68)。
- DSA的HSROC模型:DOR 3.94(95%CI 2.71-5.73),AUC 0.71(原文写作90.67-0.75,按上下文应为0.67-0.75)。
- CTA侧支评分:汇总敏感度0.74(95%CI 0.64-0.82),汇总特异度0.53(95%CI 0.44-0.62)。
- CTA的HSROC模型:DOR 3.17(95%CI 2.34-4.50),AUC 0.67(95%CI 0.63-0.71)。
- 验前概率26.3%时,DSA与CTA侧支评分检测90天良好功能结局的验后概率分别仅升至39%和36%。
临床应用与阅片要点
- DSA与CTA侧支循环评分可用于动脉内血管内取栓术前筛查,但不宜单独用于预测90天功能结局。
- 原文指出侧支评分系统更适合筛查而非诊断,阅片报告时应结合其他临床信息综合判断。
局限性
- 原文指出DSA与CTA在预测功能结局方面作用有限,更适合筛查而非诊断。
- 原文指出不同侧支循环评分系统之间存在差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study compared the diagnostic accuracy of pretreatment circulation collateral scoring (CS) system using digital subtraction angiography (DSA) and computed tomography angiography (CTA) in predicting favorable functional outcome (FFO) after intra-arterial endovascular thrombectomy (IA-EVT). Subgroup analysis characterizing scoring systems within each category was additionally conducted.
MATERIALS AND METHODS: We performed a diagnostic meta-analysis to assess the sensitivity and specificity of each CS system by using DSA and CTA, respectively. The hierarchical summary receiver operating characteristic curve (HSROC) models were used to estimate the diagnostic odds ratio (DOR) and area under the curve (AUC). The Bayes theorem was employed to determine posttest probability (PTP).
RESULTS: In total, 14 and 21 studies were assessed with DSA and CTA, respectively. In DSA, the pooled sensitivity and specificity were 0.72 (95% CI, 0.63-0.79) and 0.61 (0.53-0.68), respectively, and in the HSROC model, the DOR was 3.94 (2.71-5.73), and the AUC was 0.71 (90.67-0.75). CTA revealed a pooled sensitivity and specificity of 0.74 (0.64-0.82) and 0.53 (0.44-0.62), respectively, and in the HSROC model, the DOR was 3.17 (2.34-4.50), and the AUC was 0.67 (0.63-0.71). With a pretest probability of 26.3%, the CS in DSA and CTA exhibited limited increase of PTPs of 39% and 36%, respectively, in detecting the FFO on day 90.
CONCLUSION: DSA and CTA have comparable accuracy and are limited in predicting the functional outcome. The collateral score systems assessed with DSA and CTA were more suitable for screening than diagnosis for patients before IA-EVT.
KEY POINTS: • Our study revealed the differences of various scoring systems for assessing collateral status. • DSA and CTA have comparable accuracy, but both imaging modalities played relatively limited roles in predicting functional outcome on day 90. • The collateral score systems assessed with DSA and CTA were more suitable for screening than diagnosis for patients before IA-EVT.
引用
- Lu, Lin, Hou, et al. Diagnostic test accuracy of pretreatment collateral score in predicting stroke outcomes after intra-arterial endovascular thrombectomy: a meta-analysis in DSA and CTA. Eur Radiol. 2022. PMID: 35322281. doi:10.1007/s00330-022-08706-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。