自动自适应迭代金属伪影减少AiMAR算法在疑似膀胱恶性肿瘤患者髋关节假体CT成像中的效用
本研究纳入32例(女性8例)疑似膀胱恶性肿瘤且带髋关节假体的CT尿路造影患者,比较滤波反投影(FBP)、迭代金属伪影减少(iMAR)与自适应迭代金属伪影减少(AiMAR)强度4三种重建方法。结果显示iMAR与AiMAR在解剖结构显示和伪影评分上均优于FBP(均P<0.001),两者间相似(P>0.05),并提高了诊断信心(P<0.001)和患者层面恶性肿瘤信心(P≤0.24)。
要点
- iMAR和AiMAR的解剖结构显示与伪影评分均优于FBP(均P<0.001),两者间相似(P>0.05)。
- iMAR和AiMAR提高了诊断信心(P<0.001)和患者层面恶性肿瘤信心(P≤0.24)。
- 伪影减少算法改善最明显的结构包括闭孔内肌、髂内和髂外淋巴结链及阴道。
核心结论
- 对于带髋关节假体且疑似膀胱恶性肿瘤的患者,使用iMAR或AiMAR可显著减少金属伪影,从而提高诊断信心和患者层面恶性肿瘤信心。
研究设计与样本
- 研究纳入32例(女性8例)平均年龄74.5±8.5岁、带髋关节假体并因疑似膀胱恶性肿瘤行CT尿路造影的患者,图像采用FBP、iMAR和AiMAR强度4三种方法重建,由三名放射科医生在多阅读 session 中以盲法对关键解剖结构显示、伪影严重程度(6分制,分数越低越好)及患者层面恶性肿瘤信心进行评分。
诊断标准与关键数值
- FBP、iMAR和AiMAR的中位(范围)显示评分分别为3.6(1.1-4.9)、1.6(0.3-2.8)和1.6(0.3-2.6);iMAR和AiMAR的解剖显示与伪影评分均优于FBP(均P<0.001),两者间相似(P>0.05);iMAR和AiMAR提高诊断信心(P<0.001)和患者层面恶性肿瘤信心(P≤0.24)。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To compare the utility of a novel metal artifact reduction algorithm to standard imaging in improving visualization of key structures, diagnostic confidence, and patient-level confidence in malignancy in patients with suspected bladder cancer.
METHODS: Patients with hip implants undergoing CT urography for suspected bladder malignancy were enrolled. Images were reconstructed using 3 methods: (1) Filtered Back Projection (FBP), (2) Iterative Metal Artifact Reduction (iMAR), and (3) Adaptive Iterative Metal Artifact Reduction (AiMAR) strength 4. In multiple reading sessions, three radiologists graded visualization of critical anatomic structures and artifact severity (6-point scales, lower scores desirable), and diagnostic confidence in blinded fashion. They also graded patient-level confidence in malignancy based on imaging findings in each patient.
RESULTS: Thirty-two patients (8 females) with a mean age of 74.5 ± 8.5 years were included. The median (range) visualization scores for FBP, iMAR, and AiMAR were 3.6 (1.1-4.9), 1.6 (0.3-2.8), and 1.6 (0.3-2.6), respectively. Both iMAR and AiMAR had anatomic visualization and artifact scores better than FBP (P < 0.001 for both) and similar to each other (P > 0.05). Structures with the most improvement in visualization score with the use of metal artifact reduction algorithms included the obturator internus muscle, internal and external iliac nodal chains, and vagina. iMAR and AiMAR improved diagnostic confidence (P < 0.001) and patient-level confidence in malignancy (P ≤ 0.24).
CONCLUSION: For patients with hip prostheses and suspected bladder malignancy, the use of iMAR or AiMAR was shown to significantly reduce metal artifacts, thus improving diagnostic confidence and patient-level confidence in malignancy.
引用
- Mohammadinejad, Khandelwal, Inoue, et al. Utility of an automatic adaptive iterative metal artifact reduction AiMAR algorithm in improving CT imaging of patients with hip prostheses evaluated for suspected bladder malignancy. Abdom Radiol (NY). 2022. PMID: 35320381. doi:10.1007/s00261-022-03475-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。