压缩感知加速的三维液体与白质抑制磁共振序列较标准二维成像提高多发性硬化颈髓病灶检出
前瞻性3T扫描回顾性分析58例多发性硬化患者,比较压缩感知三维FLAWS与参考二维T2加权成像对颈髓病灶的检出。FLAWS检出病灶数显著更多(197 vs 152,P<0.001),共识阅读敏感度98%(T2WI为90%),阅读者诊断自信度中位数5分 vs 4分(P<0.001)。
要点
- 压缩感知三维FLAWS在临床可接受时间内(5分40秒)检出颈髓病灶数显著多于二维T2WI(197 vs 152,P<0.001)。
- 共识阅读下FLAWS敏感度98%,二维T2WI敏感度90%。
- FLAWS阅读者诊断自信度中位数5分(四分位距1)优于二维T2WI的4分(四分位距1),P<0.001。
核心结论
- 压缩感知三维FLAWS较常规二维T2加权成像能改善多发性硬化颈髓探查,检出更多病灶并提高阅读者诊断自信度,且扫描时间在临床可接受范围内。
研究设计与样本
- 前瞻性3T扫描(多发性硬化首诊或随访)于2019至2020年间采集,回顾性分析;纳入58例患者(平均年龄40±13岁,46例女性,平均病程7±6年);所有患者均行三维压缩感知FLAWS(时长5分40秒)、覆盖颈髓的轴位T2 turbo自旋回波、矢状位颈髓T2/短tau反转恢复成像;两名阅读者进行两阶段双盲阅读后共识阅读;采用Wilcoxon检验比较FLAWS与参考二维T2加权成像的检出病灶数和阅读者诊断自信度。
诊断标准与关键数值
- 共识阅读下压缩感知FLAWS检出197个病灶 vs 参考二维T2加权成像152个病灶(P<0.001),FLAWS敏感度98%,二维T2WI敏感度90%;在行矢状位T2+短tau反转恢复成像的多发性硬化亚组中,FLAWS检出63个病灶 vs 25个病灶(P<0.001),病灶数增加250%;阅读者诊断自信度中位数FLAWS 5分(四分位距1,诊断无疑问)vs 二维T2WI 4分(四分位距1,高自信),P<0.001。
临床应用与阅片要点
- 作者结论认为压缩感知三维FLAWS可在临床可接受时间内改善多发性硬化颈髓探查,较常规二维T2加权成像提高诊断自信度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Fluid and white matter suppression (FLAWS) is a recently proposed magnetic resonance sequence derived from magnetization-prepared 2 rapid acquisition gradient-echo providing 2 coregistered datasets with white matter- and cerebrospinal fluid-suppressed signal, enabling synthetic imaging with amplified contrast. Although these features are high potential for brain multiple sclerosis (MS) imaging, spinal cord has never been evaluated with this sequence to date. The objective of this work was therefore to assess diagnostic performance and self-confidence provided by compressed-sensing (CS) 3-dimensional (3D) FLAWS for cervical MS lesion detection on a head scan that includes the cervical cord without changing standard procedures.
MATERIALS AND METHODS: Prospective 3 T scans (MS first diagnosis or follow-up) acquired between 2019 and 2020 were retrospectively analyzed. All patients underwent 3D CS-FLAWS (duration: 5 minutes 40 seconds), axial T 2 turbo spin echo covering cervical spine from cervicomedullary junction to the same inferior level as FLAWS, and sagittal cervical T 2 /short tau inversion recovery imaging. Two readers performed a 2-stage double-blind reading, followed by consensus reading. Wilcoxon tests were used to compare the number of detected spinal cord lesions and the reader's diagnostic self-confidence when using FLAWS versus the reference 2D T 2 -weighted imaging.
RESULTS: Fifty-eight patients were included (mean age, 40 ± 13 years, 46 women, 7 ± 6 years mean disease duration). The CS-FLAWS detected significantly more lesions than the reference T 2 -weighted imaging (197 vs 152 detected lesions, P < 0.001), with a sensitivity of 98% (T 2 -weighted imaging sensitivity: 90%) after consensual reading. Considering the subgroup of patients who underwent sagittal T2 + short tau inversion recovery imaging (Magnetic Resonance Imaging for Multiple Sclerosis subgroup), +250% lesions were detected with FLAWS (63 vs 25 lesions detected, P < 0.001). Mean reading self-confidence was significantly better with CS-FLAWS (median, 5 [interquartile range, 1] [no doubt for diagnosis] vs 4 [interquartile range, 1] [high confidence]; P < 0.001).
CONCLUSIONS: Imaging with CS-FLAWS provides an improved cervical spinal cord exploration for MS with increased self-confidence compared with conventional T 2 -weighted imaging, in a clinically acceptable time.
引用
- Emorine, Megdiche, Brugières, et al. 3-Dimensional Fluid and White Matter Suppression Magnetic Resonance Imaging Sequence Accelerated With Compressed Sensing Improves Multiple Sclerosis Cervical Spinal Cord Lesion Detection Compared With Standard 2-Dimensional Imaging. Invest Radiol. 2022. PMID: 35318971. doi:10.1097/RLI.0000000000000874
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。