MRI与X线摄影诊断全膝关节置换术后假体组件松动的诊断效能比较
这项回顾性研究纳入2018年7月至2019年6月间因翻修术前行MRI和X线摄影的116例全膝关节置换术后膝关节,评估MRI对组件-骨界面特征判读的阅片者间可重复性及诊断松动的效能,并与X线摄影比较。结果显示MRI阅片者间可重复性为中等至优秀,对髌骨组件松动的敏感度高于X线摄影(84% vs 31%,P < .001),但特异度较低(85% vs 96%,P = .003),股骨和胫骨组件松动方面两者无显著差异。
要点
- MRI诊断髌骨组件松动的敏感度高于X线摄影(84% vs 31%),但特异度较低(85% vs 96%)。
- MRI对股骨和胫骨组件松动的诊断效能与X线摄影无显著差异。
- 液体界面、骨溶解、无正常界面、骨整合差及骨髓水肿模式均与松动相关。
核心结论
- MRI阅片者间可重复性为中等至优秀,诊断髌骨组件松动的敏感度高于X线摄影,但特异度较低;股骨和胫骨组件松动方面两者无显著差异。
研究设计与样本
- 回顾性研究,纳入2018年7月至2019年6月间因翻修术前行MRI和X线摄影的连续全膝关节置换术后膝关节116例(114例患者,平均年龄63岁±10[SD],女性59例),以手术所见为参考标准。
关键影像表现/征象
- 评估界面类型(正常、纤维膜、液体、骨溶解)、骨整合百分比(<33%、33%-66%、>66%)及骨髓水肿模式。
- 液体界面与松动相关(OR 20.1;95% CI: 5.7, 70.9)。
- 骨溶解与松动相关(OR 3.1;95% CI: 1.8, 5.3)。
- 无任何正常界面与松动相关(OR 11.8;95% CI: 6.3, 22.2)。
- 骨整合差(<33%)与松动相关(OR 20.4;95% CI: 9.7, 42.6),骨髓水肿模式与松动相关(OR 4.7;95% CI: 2.8, 7.8)。
诊断标准与关键数值
- MRI诊断松动的标准为无或几乎无正常界面存在。
- 髌骨组件:MRI敏感度84%(27/32;95% CI: 72, 97),特异度85%(71/84;95% CI: 77, 92)。
- 股骨组件:MRI敏感度31%(8/26;95% CI: 13, 49),特异度100%(90/90;95% CI: 100, 100)。
- 胫骨组件:MRI敏感度81%(22/27;95% CI: 66, 96),特异度98%(87/89;95% CI: 95, 100)。
- 髌骨组件松动:MRI敏感度84% vs X线摄影31%(P < .001),MRI特异度85% vs X线摄影96%(P = .003);股骨组件:MRI敏感度31% vs X线摄影46%(P = .20),MRI特异度100% vs X线摄影99%(P > .99);胫骨组件:MRI敏感度81% vs X线摄影70%(P = .16),MRI特异度98% vs X线摄影97%(P = .32)。
临床应用与阅片要点
- MRI可用于评估全膝关节置换术后组件-骨界面,阅片者间可重复性为中等至优秀(Gwet一致系数0.67-0.96)。
- 诊断髌骨组件松动时,MRI敏感度高于X线摄影但特异度较低,需结合其他征象综合判断。
- 液体界面、骨溶解、无正常界面、骨整合差及骨髓水肿模式的出现与松动相关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Because loosening of total knee arthroplasty (TKA) occurs due to poor osseous integration at component-bone interfaces, interface assessment may be helpful in diagnosing loosening at MRI. Purpose To determine interreader reproducibility for characterizing component interfaces and diagnosing loosening and to evaluate the diagnostic performance of MRI for diagnosing loosening after TKA compared with radiography. Materials and Methods Consecutive knees with TKA that underwent revision between July 2018 and June 2019 and were imaged at MRI and radiography were included in this retrospective study. Interface type (normal, fibrous membrane, fluid, or osteolysis), percent integration (<33%, 33%-66%, or >66%), and presence of bone marrow edema pattern were assessed. Loosening was diagnosed at MRI if no or almost no normal interface was present. Sensitivity and specificity were compared with radiographs by using surgical findings as reference. Gwet agreement coefficient evaluated interreader reproducibility between two readers and multivariable logistic regression assessed risk factors for loosening. Results Among 116 knees in 114 patients (mean age, 63 years ± 10 [SD]; 59 women), 61 of 116 knees (52.6%) had at least one loose component. Interreader reproducibility of MRI was substantial to excellent (Gwet agreement coefficient, 0.67-0.96). Loosening was associated with fluid interface (odds ratio [OR], 20.1; 95% CI: 5.7, 70.9) or osteolysis (OR, 3.1; 95% CI: 1.8, 5.3), absence of any normal interface (OR, 11.8; 95% CI: 6.3, 22.2), poor (<33%) osseous integration (OR, 20.4; 95% CI: 9.7, 42.6), and bone marrow edema pattern (OR, 4.7; 95% CI: 2.8, 7.8). Sensitivity and specificity of MRI for loosening were 84% (27 of 32; 95% CI: 72, 97) and 85% (71 of 84; 95% CI: 77, 92) for the patellar, 31% (eight of 26; 95% CI: 13, 49) and 100% (90 of 90; 95% CI: 100, 100) for the femoral, and 81% (22 of 27; 95% CI: 66, 96) and 98% (87 of 89; 95% CI: 95, 100) for the tibial component, respectively. MRI had higher sensitivity (84% vs 31%; P < .001) but lower specificity (85% vs 96%; P = .003) for patellar component loosening than did radiography, respectively, whereas no evidence of a difference was found for femoral (sensitivity and specificity, MRI vs radiography: 31% vs 46% [P = .20] and 100% vs 99% [P > .99], respectively) or tibial (sensitivity and specificity, MRI vs radiography: 81% vs 70% [P = .16] and 98% vs 97% [P = .32], respectively) component loosening. Conclusion MRI demonstrated substantial to excellent interreader reproducibility and higher sensitivity than did radiography for diagnosing patellar component loosening after total knee arthroplasty. © RSNA, 2022 Online supplemental material is available for this article.
引用
- Endo, Burge, Koff, et al. Diagnostic Performance of MRI for Component Loosening in Total Knee Arthroplasty Compared with Radiography. Radiology. 2022. PMID: 35315718. doi:10.1148/radiol.204458
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。