文献速递腹部技术与安全US

二维剪切波弹性成像测量肝脏硬度预测肝细胞癌患者肝切除术后症状性肝衰竭的价值

The value of liver stiffness measured by two-dimensional shear wave elastography for predicting symptomatic posthepatectomy liver failure in patients with hepatocellular carcinoma.
PubMed 文献 · Eur J Radiol · 2022-03-12

本研究纳入2018年8月至2021年7月间因肝细胞癌行肝切除术的130例患者,评估术前二维剪切波弹性成像肝脏硬度测量(LSM)预测症状性肝切除术后肝衰竭(PHLF)的价值。症状性PHLF发生于40例(30.8%)。LSM预测症状性PHLF的最佳截止值为9.5 kPa,其AUC为0.732(95%CI:0.638-0.826,p<0.001),显著高于临床显著门脉高压(CSPH)的0.594(p=0.010),与病理纤维化分期的0.655相当(p=0.073)。多因素分析显示LSM≥9.5 kPa、大范围肝切除和CSPH诊断是症状性PHLF的独立预测因素。

要点

  • 二维剪切波弹性成像肝脏硬度测量预测症状性肝切除术后肝衰竭的AUC为0.732(95%CI:0.638-0.826)。
  • LSM预测症状性PHLF的最佳截止值为9.5 kPa,其预测性能显著优于CSPH(p=0.010)。
  • LSM≥9.5 kPa、大范围肝切除和CSPH诊断是症状性PHLF的独立预测因素。

核心结论

  • 二维剪切波弹性成像肝脏硬度测量对预测肝细胞癌患者症状性肝切除术后肝衰竭有应用前景,其预测性能高于CSPH,与病理纤维化分期相当。

研究设计与样本

  • 研究纳入2018年8月至2021年7月间因肝细胞癌行肝切除术的130例患者,术前均行二维剪切波弹性成像肝脏硬度测量及其他临床病理检查,评估LSM、CSPH和纤维化分期预测症状性PHLF的性能并进行比较。

诊断标准与关键数值

  • LSM预测症状性PHLF的最佳截止值为9.5 kPa,AUC为0.732(95%CI:0.638-0.826,p<0.001)。
  • 病理纤维化分期预测症状性PHLF的AUC为0.655(95%CI:0.553-0.758,p=0.005)。
  • CSPH预测症状性PHLF的AUC为0.594(95%CI:0.484-0.705,p=0.086)。
  • LSM≥9.5 kPa的AUC显著高于CSPH(p=0.010),与纤维化分期相当(p=0.073)。

临床应用与阅片要点

  • 术前可应用二维剪切波弹性成像测量肝脏硬度,以9.5 kPa为截止值评估症状性肝切除术后肝衰竭风险。
  • LSM≥9.5 kPa、大范围肝切除和CSPH诊断是症状性PHLF的独立预测因素,阅片时可结合这些因素综合评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess and compare the value of liver stiffness measurement (LSM) by two-dimensional shear wave elastography (2D-SWE) with the diagnosis of clinically significant portal hypertension (CSPH) and pathological examination in predicting symptomatic posthepatectomy liver failure (PHLF) in patients with hepatocellular carcinoma (HCC).

METHOD: A total of 130 patients who underwent liver resection for HCC between August 2018 and July 2021 were enrolled. Preoperative assessments for LSM and other clinicopathological tests were performed in all patients. The performance of LSM, CSPH and fibrosis stage in predicting symptomatic PHLF was assessed and compared. Univariate and multivariate analyses were conducted on the risk factors for symptomatic PHLF.

RESULTS: Symptomatic PHLF occurred in 40 patients (30.8%). The best LSM cutoff value for predicting symptomatic PHLF was 9.5 kPa. The areas under the receiver operating characteristic curve (AUCs) of LSM ≥ 9.5 kPa, fibrosis stage and CSPH for predicting symptomatic PHLF were 0.732 (95% CI: 0.638-0.826, p < 0.001), 0.655 (95% CI: 0.553-0.758, p = 0.005) and 0.594 (95% CI: 0.484-0.705, p = 0.086), respectively. The AUC of LSM ≥ 9.5 kPa was significantly higher than that of CSPH (p = 0.010), and was comparable to that of fibrosis stage (p = 0.073). Multivariate analysis identified LSM ≥ 9.5 kPa (p = 0.001), major hepatectomy (p = 0.007) and CSPH diagnosis (p = 0.040) as independent predictors of symptomatic PHLF.

CONCLUSIONS: LSM by 2D-SWE was promising for predicting symptomatic PHLF in HCC patients. The predictive performance was higher than that of CSPH and comparable to that of pathological fibrosis stage.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Shi, Long, Zhong, et al. The value of liver stiffness measured by two-dimensional shear wave elastography for predicting symptomatic posthepatectomy liver failure in patients with hepatocellular carcinoma. Eur J Radiol. 2022. PMID: 35299113. doi:10.1016/j.ejrad.2022.110248

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。