使用高频(2-9 MHz)凸阵探头测量儿童衰减系数包括脂肪肝
本回顾性研究纳入118例连续接受腹部超声的儿童,评估高频凸阵探头(2-9 MHz)测量超声引导衰减参数(UGAP)的可行性和诊断脂肪肝的能力。AC2-9测量成功率98.3%,其四分位距与中位数比值低于AC1-6(4.3 vs 8.5,p<0.001),且与MR脂肪分数正相关(系数=0.498,p<0.001)。诊断脂肪肝的AC2-9截断值为0.699 dB/cm/MHz,敏感度90.2%,特异度100%。
要点
- 高频凸阵探头(2-9 MHz)测量儿童肝脏衰减系数可行,成功率98.3%。
- AC2-9测量变异性低于AC1-6(四分位距/中位数比值4.3 vs 8.5,p<0.001)。
- AC2-9诊断儿童脂肪肝截断值0.699 dB/cm/MHz,敏感度90.2%,特异度100%。
核心结论
- 使用高频凸阵探头测量衰减系数在低龄儿童中可行,测量变异性较低,AC2-9对儿童脂肪肝具有良好诊断性能。
研究设计与样本
- 回顾性研究,纳入2020年7月至12月连续接受腹部超声检查的儿童118例(男:女=83:35,平均年龄10.2±4.1岁),使用LOGIQ E10系统(GE Healthcare)的1-6 MHz(AC1-6)和2-9 MHz(AC2-9)探头测量肝脏衰减系数。
诊断标准与关键数值
- AC2-9测量成功率98.3%(116/118);AC1-6适用于肝脏深度大于9 cm的儿童;AC2-9诊断脂肪肝的截断值为0.699 dB/cm/MHz,敏感度90.2%,特异度100%;AC2-9与MR脂肪分数正相关(系数=0.498,p<0.001)。
临床应用与阅片要点
- 在儿童脂肪肝评估中,可考虑使用高频凸阵探头(2-9 MHz)测量衰减系数,其测量变异性较低且诊断性能良好。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
We evaluated the measurement feasibility and diagnostic ability of an ultrasound-guided attenuation parameter (UGAP) using a high-frequency convex transducer in children. This retrospective study included all consecutive children who underwent abdomen ultrasonography from July to December 2020. Attenuation coefficients (ACs) of the liver were measured using both 1- to 6-MHz (AC1-6) and 2- to 9-MHz (AC2-9) probes of the LOGIQ E10 system (GE Healthcare). t-Tests and Pearson's or partial correlation analyses were performed, and AC cutoff values for diagnosing fatty liver were obtained from receiver operating characteristic curve analyses. Finally, 118 patients (M:F = 83:35, mean age: 10.2 ± 4.1 y) were evaluated, and the measurement success rate was 98.3% (116/118) for AC2-9. AC1-6 was available in children with a liver depth greater than 9 cm. The ratio of interquartile range to median of the AC2-9 was lower than that of the AC1-6 (4.3 vs. 8.5, p < 0.001). In the normal group (n = 41), the AC2-9 values were not associated with age, sex or body mass index. For the evaluation of steatosis, the AC2-9 values exhibited a positive correlation with the MR fat fraction (coefficient = 0.498, p < 0.001). The cutoff value of 0.699 dB/cm/MHz had 90.2% sensitivity and 100% specificity for diagnosing fatty liver. In conclusion, measurements of ACs using a high-frequency convex transducer are feasible even in small children, with lower measurement variability. The AC2-9 values also had good diagnostic performance for pediatric fatty liver.
引用
- Yoon, Kim, Lim, et al. Attenuation Coefficient Measurement Using a High-Frequency (2-9 MHz) Convex Transducer for Children Including Fatty Liver. Ultrasound Med Biol. 2022. PMID: 35296397. doi:10.1016/j.ultrasmedbio.2022.02.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。