双层光谱探测器CT用于降低对比剂浓度、剂量和注射速率:在肠系膜上动脉成像中的效用
前瞻性纳入102例因疑似腹部疾病行腹部动脉期增强双层光谱探测器CT检查的患者,分为对照组、低浓度/剂量组(370-0.7、300-1.0、300-0.9)和低注射速率组(2-370、2-350),比较常规图像与虚拟单色图像40-140 keV对肠系膜上动脉的图像质量。结果显示各组虚拟单色图像在60 keV时图像质量最佳,低浓度/剂量组和2-370组VMI60 keV的客观与主观指标等于或优于对照组常规图像。
要点
- 双层光谱探测器CT虚拟单色图像在60 keV时肠系膜上动脉图像质量最佳。
- 低浓度/剂量组VMI60 keV的肠系膜上动脉图像质量等于或优于对照组常规图像。
- 高浓度对比剂(370 mgI/ml)注射速率降至2.0 ml/s时,VMI60 keV图像质量与对照组常规图像相当。
核心结论
- 使用双层光谱探测器CT的VMI60 keV可有效降低对比剂负荷,同时提供与常规对比剂方案获得的常规图像相当或更好的肠系膜上动脉图像质量。
研究设计与样本
- 前瞻性研究,共纳入102例因疑似腹部疾病行腹部动脉期增强双层光谱探测器CT检查的患者,分为对照组、低浓度/剂量组(370-0.7、300-1.0、300-0.9)和低注射速率组(2-370、2-350);原始数据采用混合迭代重建和投影空间光谱重建算法重建,分析常规图像和虚拟单色图像40-140 keV(间隔10 keV)的肠系膜上动脉图像质量。
关键影像表现/征象
- 各组肠系膜上动脉虚拟单色图像在60 keV时图像质量最佳,且各组VMI60 keV不同程度优于各自常规图像。
- 低浓度/剂量组和低注射速率组的常规图像客观指标(CT值、对比噪声比、信噪比)和主观评分不同程度低于对照组常规图像。
- 低浓度/剂量组和2-370组VMI60 keV的上述指标等于或甚至优于对照组常规图像。
诊断标准与关键数值
- 图像质量客观评价指标包括肠系膜上动脉的CT值、对比噪声比、信噪比和直径;直径通过CT值轮廓曲线及其半高全宽确定。
- 两名医生根据5分制独立评价多平面重组冠状面图像和容积再现图像的主观图像质量。
临床应用与阅片要点
- 在双层光谱探测器CT腹部动脉期成像中,采用VMI60 keV可在降低对比剂浓度/剂量或注射速率时维持肠系膜上动脉图像质量。
- 高浓度对比剂(370 mgI/ml)注射速率降至2.0 ml/s时,VMI60 keV的肠系膜上动脉图像质量与对照组常规图像相当。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the feasibility of contrast agent and injection rate reduction for dual-layer spectral detector computed tomography (SDCT) imaging of the superior mesenteric artery (SMA) using virtual monochromatic image (VMI).
METHODS: A total of 102 patients who underwent abdominal arterial phase-enhanced SDCT examination due to suspected abdominal diseases were prospectively selected and divided into control group, low concentration/dose groups (groups 370-0.7, 300-1.0, and 300-0.9) and low injection rate groups (groups 2-370 and 2-350). Compared with the control group, low concentration/dose groups and low injection rate groups lowered the concentration/dose or injection rate of the contrast agent to varying degrees. The raw data obtained in each group were reconstructed using hybrid-iterative reconstruction and projection spatial-spectral reconstruction algorithm. The image quality of the SMA in conventional images (CI) and in VMIs40-140 kiloelectron volt (keV) (interval: 10 keV) during the arterial phase was analyzed. Multiplanar reformation images and volume rendering images of the SMA were reconstructed. Image quality objective evaluation indexes included the CT values, contrast-to-noise ratio, signal-to-noise ratio, and diameter of the SMA. The diameter of the SMA was determined by the CT values profile curve and its full width at half maximum. Two doctors independently evaluated the subjective image quality of multiplanar reformation coronal images and volume rendering images according to a 5-point scale. Repeated analysis of variance and Friedman test were used to compare the differences in the objective evaluation indexes and subjective scores between VMIs and CI in the same group. The Dunnett's t-test or Dunnett's T3 test and Kruskal-Wallis H-test were used to compare the differences in the objective evaluation indexes and subjective scores between the experimental and control groups.
RESULTS: VMIs of the SMA in each group had the best image quality at 60 keV, and VMI60 keV in each group were better than their respective CI to varying degrees. Although the objective (CT values, contrast-to-noise ratio, and signal-to-noise ratio) and subjective (subjective scores) indexes of CI in the low concentration/dose groups and low injection rate groups were lower than those of CI in the control group to varying degrees, these indexes of VMI60 keV in the low concentration/dose groups and group 2-370 were equal to or even better than the CI in the control group.
CONCLUSIONS: VMI60 keV using SDCT could effectively reduce the contrast agent load while providing equivalent or better SMA image quality compared with CI obtained using a conventional contrast agent protocol. When the injection rate was lowered to 2.0 ml/s for a high-concentration contrast agent (370 mgI/ml), the SMA image quality at VMI60 keV was comparable with that of the CI in the control group.
引用
- Lai, Tan, Jiang, et al. Dual-layer spectral detector CT for contrast agent concentration, dose and injection rate reduction: Utility in imaging of the superior mesenteric artery. Eur J Radiol. 2022. PMID: 35294908. doi:10.1016/j.ejrad.2022.110246
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。