文献速递骨肌CTMR

基于双能CT后处理方法的急性膝关节韧带损伤后骨髓水肿成像诊断准确性

Diagnostic accuracy of a dual-energy computed tomography-based post-processing method for imaging bone marrow edema following an acute ligamentous knee injury.
PubMed 文献 · Skeletal Radiol · 2022-03-15

研究纳入35例急性前交叉韧带损伤患者,评估自定义双能CT材料分解后处理方法显示骨髓水肿的能力,并以流体敏感MRI为金标准进行体素级定量比较和盲法半定量评分。结果显示两位阅片者胫骨敏感度0.67和0.74、股骨0.55和0.57,胫骨特异度0.87和0.89、股骨0.58和0.89;胫骨和股骨平均Dice系数分别为0.40和0.16。作者结论认为该DECT方法诊断准确性与既往使用CT厂商内置水肿成像应用的研究相似,定量指标比半定量评分更严格。

要点

  • 自定义双能CT后处理方法显示急性膝关节韧带损伤后骨髓水肿,胫骨敏感度0.67和0.74、特异度0.87和0.89(两位阅片者)。
  • 股骨敏感度0.55和0.57、特异度0.58和0.89,股骨特异度在两位阅片者间差异较大。
  • 体素级定量评估的胫骨和股骨平均Dice系数分别为0.40和0.16,作者认为定量指标比半定量评分更严格。

核心结论

  • 基于自定义后处理的双能CT方法显示骨髓水肿的诊断准确性与既往使用CT厂商内置水肿成像应用评估膝关节韧带损伤相关水肿的研究相似;定量结局指标比半定量评分方法更严格,这解释了平均Dice系数偏低。

研究设计与样本

  • 研究纳入35例急性前交叉韧带损伤参与者的图像,将双能CT材料组成分析用于识别骨髓水肿,并以配准的流体敏感MRI为金标准进行体素级定量比较;另由两位盲法阅片者对双能CT和流体敏感MRI图像上的水肿存在与否进行评分以评估诊断准确性。

关键影像表现/征象

  • 双能CT材料组成分析用于识别骨髓水肿,并与配准的流体敏感MRI进行体素级比较。
  • 两位盲法阅片者分别对双能CT和流体敏感MRI图像上的水肿存在进行评分。

诊断标准与关键数值

  • 胫骨水肿敏感度:阅片者1为0.67、阅片者2为0.74;胫骨特异度:阅片者1为0.87、阅片者2为0.89。
  • 股骨水肿敏感度:阅片者1为0.55、阅片者2为0.57;股骨特异度:阅片者1为0.58、阅片者2为0.89。
  • 定量水肿分割准确性平均Dice系数:胫骨0.40、股骨0.16。

临床应用与阅片要点

  • 作者结论认为该自定义后处理双能CT方法的诊断准确性与既往使用CT厂商内置水肿成像应用的研究相似。
  • 作者指出定量结局指标比半定量评分方法更严格,平均Dice系数偏低与此有关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study evaluated the ability of a custom dual-energy CT (DECT) post-processing material decomposition method to image bone marrow edema after acute knee injury. Using an independent validation cohort, the DECT method was compared to gold-standard, fluid-sensitive MRI. By including both quantitative voxel-by-voxel validation outcomes and semi-quantitative radiologist scoring-based assessment of diagnostic accuracy, we aimed to provide insight into the relationship between quantitative metrics and the clinical utility of imaging methods.

MATERIALS AND METHODS: Images from 35 participants with acute anterior cruciate ligament injuries were analyzed. DECT material composition was applied to identify bone marrow edema, and the DECT result was quantitatively compared to gold-standard, registered fluid-sensitive MRI on a per-voxel basis. In addition, two blinded readers rated edema presence in both DECT and fluid-sensitive MR images for evaluation of diagnostic accuracy.

RESULTS: Semi-quantitative assessment indicated sensitivity of 0.67 and 0.74 for the two readers, respectively, at the tibia and 0.55 and 0.57 at the femur, and specificity of 0.87 and 0.89 for the two readers at the tibia and 0.58 and 0.89 at the femur. Quantitative assessment of edema segmentation accuracy demonstrated mean dice coefficients of 0.40 and 0.16 at the tibia and femur, respectively.

CONCLUSION: The custom post-processing-based DECT method showed similar diagnostic accuracy to a previous study that assessed edema associated with ligamentous knee injury using a CT manufacturer-provided, built-in edema imaging application. Quantitative outcome measures were more stringent than semi-quantitative scoring methods, accounting for the low mean dice coefficient scores.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. de Bakker, Peedikayil, Walker, et al. Diagnostic accuracy of a dual-energy computed tomography-based post-processing method for imaging bone marrow edema following an acute ligamentous knee injury. Skeletal Radiol. 2022. PMID: 35290479. doi:10.1007/s00256-022-04023-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。