文献速递泌尿生殖妇产影像US

经会阴剪切波弹性成像评估女性压力性尿失禁患者肛提肌的价值

Usefulness of transperineal shear wave elastography of levator ani muscle in women with stress urinary incontinence.
PubMed 文献 · Abdom Radiol (NY) · 2022-03-15

研究纳入32例压力性尿失禁女性和34例正常盆底支持女性,经会阴超声测量肛提肌厚度、膀胱颈下降和尿道漏斗,并用剪切波弹性成像测量静息和最大Valsalva动作时肛提肌弹性。压力性尿失禁组肛提肌厚度在静息和最大Valsalva动作时均大于对照组(P<0.001),所有参与者从静息到最大Valsalva动作时Emax和Emean弹性模量值显著增加,对照组变化比压力性尿失禁组更明显(P<0.05)。作者认为剪切波弹性成像量化的肛提肌弹性可能作为预测压力性尿失禁的指标。

要点

  • 压力性尿失禁组肛提肌厚度在静息和最大Valsalva动作时均大于对照组(P<0.001)。
  • 所有参与者从静息到最大Valsalva动作时Emax和Emean弹性模量值显著增加(P<0.001)。
  • 对照组从静息到最大Valsalva动作的弹性模量变化比压力性尿失禁组更明显(P<0.05)。

核心结论

  • 剪切波弹性成像量化的肛提肌弹性可能潜在作为预测压力性尿失禁的指标。

研究设计与样本

  • 研究纳入32例压力性尿失禁女性和34例正常盆底支持女性,经会阴超声评估肛提肌厚度、膀胱颈下降和尿道漏斗,剪切波弹性成像测量静息和最大Valsalva动作时肛提肌弹性。

关键影像表现/征象

  • 压力性尿失禁组肛提肌厚度在静息和最大Valsalva动作时均大于对照组(P<0.001)。
  • 所有参与者从静息到最大Valsalva动作时Emax从56.24 kPa增至82.43 kPa、Emean从47.92 kPa增至72.37 kPa(P<0.001)。
  • 对照组从静息到最大Valsalva动作的Emax变化为34.09 kPa、Emean变化为31.55 kPa,压力性尿失禁组分别为17.87 kPa和16.82 kPa(P<0.05)。

临床应用与阅片要点

  • 作者认为剪切波弹性成像量化的肛提肌弹性可能潜在作为预测压力性尿失禁的指标。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study aimed to quantitatively assess the quality of levator ani muscle (LAM) using shear wave elastography (SWE) and to evaluate the association between the elasticity of LAM and stress urinary incontinence (SUI). The study population included 32 women with SUI and 34 women with normal pelvic support. The thickness of LAM, bladder neck descent (BND), and urethral funneling (UF) were assessed by transperineal ultrasound. LAM elasticity was measured by SWE at rest and during the maximal Valsalva maneuver. Age, menopause, BND, and UF showed a positive correlation with SUI. There was no significant between-group difference in the elastic modulus values of LAM at rest. The thickness of LAM in women with SUI was greater than that in control group at rest and during the maximal Valsalva maneuver (P < 0.001). The elastic modulus values of Emax and Emean were significantly increased from rest to the maximal Valsalva maneuver in all participants (56.24 vs 82.43 kPa and 47.92 vs 72.37 kPa, P < 0.001). The change of these variables from rest to the maximal Valsalva maneuver in the control group was more obvious than that in the SUI group (34.09 vs 17.87 kPa and 31.55 vs 16.82 kPa, P < 0.05). The elasticity of LAM, as quantified by SWE, may potentially be used as an index for predicting SUI.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Li, Zhang, Li, et al. Usefulness of transperineal shear wave elastography of levator ani muscle in women with stress urinary incontinence. Abdom Radiol (NY). 2022. PMID: 35290481. doi:10.1007/s00261-022-03478-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。