文献速递神经头颈PETMR

基于混合18F-FDG PET/MRI的强化肿瘤与瘤周区域多参数成像鉴别高级别胶质瘤与原发性中枢神经系统淋巴瘤

Differentiation of high-grade glioma and primary central nervous system lymphoma: Multiparametric imaging of the enhancing tumor and peritumoral regions based on hybrid 18F-FDG PET/MRI.
PubMed 文献 · Eur J Radiol · 2022-03-07

回顾性纳入45例高级别胶质瘤(HGG)和20例原发性中枢神经系统淋巴瘤(PCNSL)患者,治疗前行同步18F-FDG PET、动脉自旋标记灌注加权成像和扩散加权成像。在强化肿瘤(ET)和瘤周区域(PTR)计算rSUVmax、rCBFmax和rADCmin,多变量逻辑回归模型鉴别两种肿瘤的AUC达0.980-0.989,准确率均为95.4%。

要点

  • 强化肿瘤区HGG的rSUVmax低于PCNSL,而rCBFmax和rADCmin高于PCNSL(均P<0.05)。
  • 瘤周区域HGG的rSUVmax和rCBFmax高于PCNSL,而rADCmin低于PCNSL(均P<0.05)。
  • 基于rSUVmax_ET、rADCmin_ET和rCBFmax_PTR的模型AUC为0.980,准确率95.4%。

核心结论

  • 基于常规MRI特征及强化肿瘤和瘤周区域定量分析的多参数18F-FDG PET/MRI诊断模型在鉴别HGG与PCNSL方面优于单参数,应考虑用于临床实践。

研究设计与样本

  • 回顾性纳入45例HGG和20例PCNSL患者,治疗前行同步18F-FDG PET、动脉自旋标记灌注加权成像和扩散加权成像的混合PET/MRI检查。

关键影像表现/征象

  • 强化肿瘤区HGG的rSUVmax显著低于PCNSL,rCBFmax和rADCmin显著高于PCNSL(均P<0.05)。
  • 瘤周区域HGG的rSUVmax和rCBFmax显著高于PCNSL,rADCmin显著低于PCNSL(均P<0.05)。

诊断标准与关键数值

  • 由rSUVmax_ET、rADCmin_ET和rCBFmax_PTR组成的逻辑回归模型鉴别HGG与PCNSL的AUC为0.980,准确率95.4%。
  • 由rSUVmax_ET、rCBFmax_PTR和强化模式组成的逻辑回归模型AUC为0.989,准确率95.4%。
  • 两个逻辑回归模型的AUC无显著差异(P=0.233)。

临床应用与阅片要点

  • 作者认为基于常规MRI特征及强化肿瘤和瘤周区域定量分析的多参数18F-FDG PET/MRI诊断模型应考虑用于临床实践。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the value of the 18F-FDG PET/MRI multiparametric model in the differentiation of high-grade glioma (HGG) and primary central nervous system lymphoma (PCNSL), with emphasis on the quantitative analysis of the enhancing tumor (ET) and non-enhancing peritumoral region (PTR).

METHODS: Forty-five patients with HGG and 20 patients with PCNSL who underwent simultaneous 18F-FDG PET, arterial spin labelling perfusion-weighted imaging and diffusion-weighted imaging with hybrid PET/MRI before treatment were retrospectively enrolled. The relative maximum standardized uptake value (rSUVmax), relative maximum cerebral blood flow (rCBFmax) and relative minimum apparent diffusion coefficient (rADCmin) in both the ET and NPR were calculated and compared between HGG and PCNSL. Multivariate logistic regression was used to determine the best logistic regression model (LRM) for classification. Receiver operating curve analysis was used to assess diagnostic performance.

RESULTS: In the ET, HGG showed significantly lower rSUVmax values but higher rCBFmax and rADCmin than PCNSL (all P < 0.05). In the PTR, HGG demonstrated significantly higher rSUVmax and rCBFmax but lower rADCmin than PCNSL (all P < 0.05). Multivariate logistic regression based on quantitative parameters revealed that the LRM consisting of rSUVmax_ET, rADCmin_ET and rCBFmax_PTR had significantly improved diagnostic performance in differentiating HGG from PCNSL than single parameter alone, with an AUC of 0.980 and an accuracy of 95.4%. Multivariate logistic regression incorporating quantitative parameters and conventional MRI features revealed that the LRM consisting of rSUVmax_ET, rCBFmax_PTR and enhancement pattern yielded a slightly higher AUC of 0.989 and an identical accuracy of 95.4%. No significant difference in AUCs was detected between the two LRMs (P = 0.233).

CONCLUSIONS: Multiparametric 18F-FDG PET/MRI diagnostic model based on conventional MRI features and quantitative analysis of the enhancing tumors and peritumoral regions is superior to single parameter in the differentiation of HGG and PCNSL, which should be considered in the clinical practice.

来源:Eur J Radiol,查看原文。版权归原作者所有。