文献速递儿科影像技术与安全DSA

在某三级医院建立儿童透视检查的诊断参考水平

Establishing diagnostic reference levels for pediatric fluoroscopic examinations in a tertiary hospital.
PubMed 文献 · Pediatr Radiol · 2022-03-14

该研究回顾性收集澳大利亚南澳某三级医院3年内365例儿童5种透视检查的剂量数据,建立本地儿童透视诊断参考水平(DRL)。本地DRL显著低于既往发表数据,患者年龄每增加1岁,钡餐及随访检查的剂量面积乘积(DAP)增加0.77 μGy·m2,钡 swallow 检查增加1.37 μGy·m2。

要点

  • 儿童透视检查的本地DRL显著低于既往发表数据,可能反映技术和操作进步。
  • 患者年龄每增加1岁,钡餐及随访检查DAP增加0.77 μGy·m2(95%CI 0.055–1.48,P=0.04)。
  • 患者年龄每增加1岁,钡 swallow 检查DAP增加1.37 μGy·m2(95%CI 0.61–2.12,P<0.001)。

核心结论

  • 本研究提供了更新的澳大利亚儿童透视DRL,旨在促进建立国家数据库以进行儿童剂量基准比较;本地DRL可用于设施间的剂量比较和优化。

研究设计与样本

  • 回顾性收集2018年1月起3年内365例接受5种透视检查的儿童患者的剂量数据,以建立本地DRL;使用散点图、Spearman相关和回归分析探讨DAP、年龄和透视时间的关系。

诊断标准与关键数值

  • 本地DRL显著低于既往发表数据,可能反映技术和操作进步。
  • 钡餐及随访检查:年龄每增加1岁,DAP增加0.77 μGy·m2(95%CI 0.055–1.48,P=0.04)。
  • 钡 swallow 检查:年龄每增加1岁,DAP增加1.37 μGy·m2(95%CI 0.61–2.12,P<0.001)。
  • 排尿性膀胱尿道造影:DAP与透视时间呈低度相关(r=0.35,95%CI 0.15–0.51,P<0.001)。
  • 钡餐及随访检查:DAP与透视时间呈低度相关(r=0.37,95%CI -0.011–0.65,P=0.05)。

临床应用与阅片要点

  • 本地DRL可用于设施间剂量比较和优化。
  • 本研究旨在促进建立国家数据库以进行儿童剂量基准比较。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Diagnostic reference levels (DRLs) identify unusually high patient radiation exposures and are required for dose optimisation. DRLs for pediatric fluoroscopic examinations are not widely determined in Australia.

OBJECTIVE: Our objectives were to establish DRLs for pediatric fluoroscopic examinations in a South Australian tertiary hospital and compare these to previously published data and to explore relationships between patient dose area product (DAP), age and fluoroscopy times.

MATERIALS AND METHODS: Dose data from 365 pediatric patients undergoing 5 fluoroscopic examinations were retrospectively collected for a 3-year period commencing January 2018 to develop local DRLs. Relationships between DAP, age and fluoroscopy time were explored using scatterplots, Spearman's correlation, and regression analyses.

RESULTS: Local DRLs were significantly lower than data published previously, possibly reflecting technological and procedural advancements. Each 1-year increase in patient age was associated with a 0.77 μGy·m2 increase in DAP for barium meal and follow-through studies (95% confidence interval [CI]=0.055, 1.48) (P=0.04), and a 1.37 μGy·m2 increase in DAP for barium swallow studies (95% CI=0.61, 2.12) (P<0.001). A low correlation was demonstrated between DAP and fluoroscopy time for micturating cystourethrography studies (r=0.35, 95% CI=0.15, 0.51, P<0.001) and barium meal and follow-through studies (r=0.37, 95% CI= -0.011, 0.65, P=0.05). Age and fluoroscopy time were not significantly related.

CONCLUSION: This study provides updated Australian pediatric fluoroscopic DRLs, with the intention of promoting a national database for benchmarking pediatric doses. The local DRLs can be used for dose comparisons and optimisation between facilities.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Gomes, Brown, Davies, et al. Establishing diagnostic reference levels for pediatric fluoroscopic examinations in a tertiary hospital. Pediatr Radiol. 2022. PMID: 35284948. doi:10.1007/s00247-022-05290-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。