衍射光学相干断层扫描在体可视化并验证气道壁微结构
研究采用800 nm超高清衍射光学相干断层扫描(OCT)系统在绵羊模型中对直径约2 mm的小气道进行在体成像,并将OCT图像与组织学配对比较。共27只绵羊、39对OCT-组织学气道图像显示OCT与组织学测量气道壁及各微结构面积呈强相关,相关系数从上皮的r=0.61到外膜的r=0.86,全气道壁r=0.76(均p<0.001)。作者据此认为该数据验证了此新型OCT系统在体获取并量化微观水平成像的能力。
要点
- 衍射OCT(800 nm)可在体显示气道壁上皮、基底膜、平滑肌、腺体、软骨及外膜等微结构。
- OCT与组织学测量气道壁面积及微结构面积呈强相关,r=0.61至0.86(均p<0.001)。
- 全气道壁OCT与组织学测量相关系数r=0.76(p<0.001)。
核心结论
- OCT与组织学测量高度相关,验证了该800 nm超高清衍射OCT系统在体获取并量化微观水平气道壁成像的能力。
研究设计与样本
- 动物实验(绵羊模型),共27只绵羊,获得39对OCT与组织学配对的气道图像;使用800 nm超高清衍射OCT系统,以组织学为参考标准,测量并比较气道壁、管腔及其他微结构的横截面积。
关键影像表现/征象
- OCT可在体显示直径约2 mm小气道的上皮、基底膜、气道平滑肌、腺体、软骨及外膜等微结构。
- OCT与组织学测量气道壁面积及上述各微结构面积呈强相关。
诊断标准与关键数值
- OCT与组织学测量上皮面积相关系数r=0.61(p<0.001)。
- OCT与组织学测量外膜面积相关系数r=0.86(p<0.001)。
- OCT与组织学测量全气道壁面积相关系数r=0.76(p<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: At present, there is no available method to study the in vivo microstructures of the airway wall (epithelium, smooth muscle, adventitia, basement membrane, glands, cartilage). Currently, we rely on ex vivo histologic evaluation of airway biopsies. To overcome this obstacle, we have developed an endoscopic ultrahigh-resolution diffractive optical coherence tomography (OCT) system, operating at a wavelength of 800 nm, to non-invasively study the in vivo microstructures of the airway wall. Prior to human study, validation of diffractive OCT's ability to quantitate airway microstructural components is required.
MATERIALS AND METHODS: To validate and demonstrate the accuracy of this OCT system, we used an ovine model to image small airways (∼ 2 mm in diameter). Histologic samples and correlated OCT images were matched. The cross-sectional area of the airway wall, lumen, and other microstructures were measured and compared.
RESULTS: A total of 27 sheep were studied from which we identified 39 paired OCT-histology airway images. We found strong correlations between the OCT and the histology measurements of the airway wall area and the microstructural area measurements of the epithelium, basement membrane, airway smooth muscle, glands, cartilage, and adventitia. The correlations ranged from r=0.61 (p<0.001) for the epithelium to r=0.86 (p<0.001) for the adventitia with the correlation between the OCT and the histology measurements for the entire airway wall of r=0.76 (p<0.001).
CONCLUSION: Given the high degree of correlation, these data validate the ability to acquire and quantify in vivo microscopic level imaging with this newly developed 800nm ultra-high resolution diffractive OCT system.