人工智能可在增强胸部CT上相对于心脏磁共振检测左心室扩大
本研究以心脏磁共振(CMR)为参考标准,评估全自动人工智能算法在非心电门控增强胸部CT上检测左心室(LV)扩大的诊断准确性。连续纳入84例在31天内完成增强胸部CT和CMR的患者,AI自动分割心室腔并给出最大LV直径和体积。结果显示自动直径分析在92%(77/84)病例中可行,男性LV直径≥55.5 mm对CMR定义的LV扩大≥90%特异(PPV 85.7%,NPV 61.2%,准确率68.9%),女性≥49.7 mm≥90%特异(PPV 66.7%,NPV 73.1%,准确率71.9%),AI CT体积测量未显著改善AUC性能。
要点
- 非心电门控增强胸部CT上,全自动AI测量最大LV轴位直径在92%(77/84)病例中可行。
- 男性LV直径≥55.5 mm对CMR定义的LV扩大≥90%特异(PPV 85.7%,NPV 61.2%,准确率68.9%)。
- 女性LV直径≥49.7 mm对CMR定义的LV扩大≥90%特异(PPV 66.7%,NPV 73.1%,准确率71.9%)。
核心结论
- 全自动AI衍生的LV扩大分析在常规非心电门控增强胸部CT上是可行的。
- 研究定义了CT相对于CMR检测LV扩大的阈值,可用于在胸部CT检查时常规筛查扩张型心肌病。
- AI CT体积测量数据未显著改善AUC性能。
研究设计与样本
- 研究类型为诊断准确性研究,以CMR为参考标准。
- 连续纳入2016-2020年间增强胸部CT与CMR间隔在31天内的患者,共84例。
- 自动直径分析可行病例为77/84(92%),其中45名男性,年龄61±14岁,CT至CMR平均间隔10±8天。
- LV扩大依据CMR的年龄、性别和体表面积特异性数值定义。
- 采用AUC-ROC分析确定CT阈值(≥90%敏感度下最高特异度,及≥90%特异度下最高敏感度),并用约登指数确定优化敏感度和特异度的阈值。
诊断标准与关键数值
- 以CMR为参考标准,45%的病例存在LV扩大。
- 男性:自动LV直径测量≥55.5 mm对CMR定义的LV扩大≥90%特异,PPV 85.7%,NPV 61.2%,准确率68.9%。
- 女性:LV直径≥49.7 mm对CMR定义的LV扩大≥90%特异,PPV 66.7%,NPV 73.1%,准确率71.9%。
- AI CT体积测量数据未显著改善AUC性能。
临床应用与阅片要点
- 作者指出,所定义的CT阈值可用于在胸部CT检查时常规筛查扩张型心肌病。
- 未来工作应验证这些阈值,并确定该技术能否以成本效益方式改变临床结局。
局限性
- 未来工作应验证这些阈值,并确定该技术能否以成本效益方式改变临床结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic accuracy of an automated algorithm to detect left ventricular (LV) dilatation on non-ECG gated CT, using cardiac magnetic resonance (CMR) as reference standard.
METHODS: Consecutive patients with contrast-enhanced CT thorax and CMR within 31 days (2016-2020) were analysed (n = 84). LV dilatation was defined against age-, sex- and body surface area-specific values for CMR. CTs underwent automated artificial intelligence(AI)-derived analysis that segmented ventricular chambers, presenting maximal LV diameter and volume. Area under the receiver operator curve (AUC-ROC) analysis identified CT thresholds with ≥90% sensitivity and highest specificity and ≥90% specificity with highest sensitivity. Youden's Index was used to identify thresholds with optimised sensitivity and specificity.
RESULTS: Automated diameter analysis was feasible in 92% of cases (77/84; 45 men, age 61 ± 14 years, mean CT to CMR interval 10 ± 8 days). Relative to CMR as a reference standard, 45% had LV dilatation. In males, an automated LV diameter measurement of ≥55.5 mm was ≥90% specific for CMR-defined LV dilatation (positive predictive value (PPV) 85.7%, negative predictive value (NPV) 61.2%, accuracy 68.9%). In females, an LV diameter of ≥49.7 mm was ≥90% specific for CMR-defined LV dilatation (PPV 66.7%, NPV 73.1%, accuracy 71.9%). AI CT volumetry data did not significantly improve AUC performance.
CONCLUSION: Fully automated AI-derived analysis LV dilatation on routine unselected non-gated contrast-enhanced CT thorax studies is feasible. We have defined thresholds for the detection of LV dilatation on CT relative to CMR, which could be used to routinely screen for dilated cardiomyopathy at the time of CT.
ADVANCES IN KNOWLEDGE: We show, for the first time, that a fully-automated AI-derived analysis of maximal LV chamber axial diameter on non-ECG-gated thoracic CT is feasible in unselected real-world cases and that the derived measures can predict LV dilatation relative to cardiac magnetic resonance imaging, the non-invasive reference standard for determining cardiac chamber size. We have derived sex-specific cut-off values to screen for LV dilatation on routine contrast-enhanced thoracic CT. Future work should validate these thresholds and determine if technology can alter clinical outcomes in a cost-effective manner.
引用
- Asif, Charters, Thompson, et al. Artificial intelligence can detect left ventricular dilatation on contrast-enhanced thoracic computer tomography relative to cardiac magnetic resonance imaging. Br J Radiol. 2022. PMID: 35286140. doi:10.1259/bjr.20210852
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。